15 Watt | AC-DC / DC-DC Converter

www.aimtec.com Tel: +1 514 620 2722 Toll free: + 1 888 9 AIMTEC (924 6832) F 052e R7.R 1 of 5 North America only FEATURES:  Screw Terminals on Input & Output  RoHS compliant  Operating temperature: -40 to +80°C  Soft start  Over load, Over Voltage, Short Circuit Protection  Energy Star compliant  Optional DIN Rail mounting bracket  CE, cULus, CB approvals  Universal input: 90-264VAC, 47-440Hz  4000VAC I/O Isolation Models Single output Model Input Voltage (VAC/Hz) Input voltage (VDC) Max Output wattage (W) Output Voltage (V) Output Current max (A) Maximum Capacitive Load (µF) Efficiency (%) 115 VAC 230 VAC AMES15-3.3SMAZ 90-264/47-440 130-370 9.9 3.3 3 4700 74 74 AMES15-5SMAZ 90-264/47-440 130-370 15 5 3 2200 75 76 AMES15-12SMAZ 90-264/47-440 130-370 15 12 1.25 1000 81 82 AMES15-15SMAZ 90-264/47-440 130-370 15 15 1 680 81 83 AMES15-24SMAZ 90-264/47-440 130-370 15 24 0.63 470 83 83 Models Dual output Model Input Voltage (VAC/Hz) Input voltage (VDC) Max Output wattage (W) Output Voltage (V) Output Current max (A) Maximum Capacitive Load (µF) Efficiency (%) 115 VAC 230 VAC AMES15-5DMAZ 90-264/47-440 130-370 15 ±5 ±1.5 ±1000 78 79 AMES15-12DMAZ 90-264/47-440 130-370 15 ±12 ±0.63 ±470 81 82 AMES15-15DMAZ 90-264/47-440 130-370 15 ±15 ±0.5 ±330 82 83 Input Specifications Parameters Conditions Typical Maximum Units Current (full load) 115VAC 350 mA 230VAC 180 mA Inrush current <2ms (cold start) 115 VAC 10 A

230 VAC 20 A

Leakage current 115 VAC 0.1 mA 264 VAC 0.2 mA External Fuse (recommend)slow blow type 2 A Input Dissipation (110/230Vac) ൑0.2 W Under Voltage Protection 85 VAC Output Specifications Parameters Conditions Typical Maximum Units Voltage accuracy ±2 % Line regulation LL-HL ±1 % Load regulation (single output) 0-100% ±1 % Cross regulation (dual output) 25% load - 1 st out, 100% load – 2nd out ±5 % Transient Recovery Time 300 µs Transient Recovery Deviation 25% load step ±2 % of Vout Ripple & Noise* 3.3/5V models 12/15V models 24V models 100 150 mVp-p Hold-up time min 20 ms * Ripple and Noise are measured at 20MHz bandwidth by using 0.1μF (M/C) and 47μF (E/C) parallel capacitor. CB Click on Series name for product info on aimtec.com

www.aimtec.com Tel: +1 514 620 2722 Toll free: + 1 888 9 AIMTEC (924 6832) F 052e R7.R 2 of 5 North America only Isolation Specifications Parameters Conditions Typical Rated Units Tested I/O voltage 60 sec 4000 VAC Isolation resistance >1000 MΩ General Specifications Parameters Conditions Typical Maximum Units Switching frequency 132 KHz Protection class Class II Start up time 350 mS Over load protection Foldback >130 % Over voltage protection Zener diode clamp Short circuit protection Auto recovery Case material Metal Operating temperature With derating over 55 oC (10CFM) -40 to +80 oC Storage temperature -50 to +100 oC Max Case temperature 100 oC Temperature coefficient ±0.02 % / oC Cooling Free air convection Humidity 95 % RH Weight 100 g MTBF > 400,000hrs (MIL-HDBK -217F, t=+25oC) > 100,000hrs (MIL-HDBK -217F, t=at highest operating temperature) NOTE: All specifications in this datasheet are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at rated output load unless otherwise specified. Environment Approval Parameters Conditions Shock Wave form: Half sine wave Acceleration amplitude: 5gn Bump duration: 30 ms Number of bumps: 18 (3 in each direction for every axis) Converter operation before and after test, body mounted (on chassis) Vibrations Test mode: Sweep sine 10-100Hz, speed 0.05Hz/s Displacement: 1mm Acceleration: 3g 3 loops 30min one cycle, 3h total, every axis tested Converter operation before and after test, body mounted (on chassis) Safety & EMC Specifications Parameters Agency approvals cULus, CE, CB Standards Medical Electrical Equipment IEC\\EN\\UL 60601-1, 2 x MOOP, CSA-C22.2 No. 601.1-M90 Information technology Equipment EN 60950-1:2006+A11:2009 EMI - Conducted and radiated emission EN55011, class B Harmonic Current Emissions IEC/EN 61000-3-2, Class A Voltage fluctuations and flicker IEC/EN 61000-3-3, (EN60555-3) Electrostatic Discharge Immunity IEC 61000-4-2 Level 3 RF, Electromagnetic Field Immunity IEC 61000-4-3 Level 2 Electrical Fast Transient/Burst Immunity IEC 61000-4-4 Level 3 Surge Immunity IEC 61000-4-5 Level 3 RF, Conducted Disturbance Immunity IEC 61000-4-6 Level 2 Power frequency Magnetic Field Immunity IEC 61000-4-8 Level 2 Voltage dips, Short Interruptions Immunity IEC 61000-4-11

www.aimtec.com Tel: +1 514 620 2722 Toll free: + 1 888 9 AIMTEC (924 6832) F 052e R7.R 3 of 5 North America only Derating - 40 - 20 0 20 40 60 80 100 Ambient Temperature º C 100 Safe Operating Area A B 40 º C A

10 CFM

55 º C B Pin Out Specifications Pin Single Dual

1 AC Input (N) AC Input (N)

2 AC Input (L) AC Input (L)

4 No Connection Common

www.aimtec.com Tel: +1 514 620 2722 Toll free: + 1 888 9 AIMTEC (924 6832) F 052e R7.R 4 of 5 North America only Dimensions Side View PCB Bracket Mountin g Screw Mylar Film PCB Mounting Screw PCB Mounting Screw 2.6 mm Max Customer Chassis PCB Mylar Film (0.94)

www.aimtec.com Tel: +1 514 620 2722 Toll free: + 1 888 9 AIMTEC (924 6832) F 052e R7.R 5 of 5 North America only Optional DIN Rail Bracket NOTE: 1. Datasheets are updated as needed and as such, specifications are subject to change without notice. Once printed or downloaded, datasheets are no longer controlled by Aimtec; refer to www.aimtec.com for the most current product specifications. 2. Product labels shown, including safety agency certifications on labels, may vary based on the date manufactured. 3. Mechanical drawings and specifications are for reference only. 4. All specifications are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at rated output load unless otherwise specified. 5. Aimtec may not have conducted destructive testing or chemical analysis on all internal components and chemicals at the time of publishing this document. CAS numbers and other limited information are considered proprietary and may not be available for release. 6. This product is not designed for use in critical life support systems, equipment used in hazardous environments, nuclear control systems or other such applications which necessitate specific safety and regulatory standards other the ones listed in this datasheet. 7. Warranty is in accordance with Aimtec’s standard Terms of Sale available at www.aimtec.com.