up to 6.3A | AC-DC / DC-DC | LED Driver / Converter www.aimtec.com Tel: +1 514 620 2722 Toll free: + 1 888 9 AIMTEC (924 6832) F 052.1e R3.Q 1 of 10 North America only FEATURES: Models Single output Model Max Output Power (W)① Output Voltage Range (V)③ Output Current (A)③ Input Voltage (VAC/Hz) Input Voltage (VDC) Mode of Operation Efficiency (%) 115 VAC 230 VAC 277 VAC AMER150-50300CAZ 150 36-50 0-3 90-305/47-440 130-430 Constant Current 87 89 89 Constant Voltage② 87 88 89 AMER150-36420CAZ 150 24-36 0-4.16 90-305/47-440 130-430 Constant Current 86 88 88 Constant Voltage② 86 88 88 AMER150-24630CAZ 151.2 12-24 0-6.3 90-305/47-440 130-430 Constant Current 85 87 87 Constant Voltage② 85 87 87 Add Suffix “-F” No dimming option ① Exceeding the maximum output power will permanently damage the converter ② The dimming feature is not supported when units are used in Constant Voltage mode only, Aimtec suggests to order “-F” No dimming option in this case. ③ In constant current mode output current is maximum shown, in constant voltage mode output voltage is the maximum shown. All models can be ordered with optional North American colour input wires (black (L), white (N), green (GND)). Add “–NA” to part number when ordering. NOTE: Aimtec limited warranty of 5 years is valid based on product operation at datasheet specifications at ambient temperature of 25°C, humidity<75%, nominal input voltage (115/230/277VAC) and at rated output load unless otherwise specified. See http://www.aimtec.com/terms-saleAMER150-CAZ’s AC/DC LED drivers have electrical safeguards designed within to protect it from conventional electrical abnormalities with the levels listed in the safety table. Applications for use within rural agricultural, heavy industrial, and other areas or regions which are prone to ‘dirty’ electrical conditions which would subject any of the above models to excessive voltages surges or spikes, may damage or cause early life failure of product. In this case consideration should be made by the end user to ensure that adequate line or mains surge suppression is installed in front of Aimtec device to ensure the longevity of the products. Failure to identify excessive line surges violations prior to installation may damage sensitive equipment permanently. Input Specifications Parameters Conditions Typical Maximum Units Current (full load)
115 VAC 2000 mA
230 VAC 1000 mA
277 VAC 900 mA
Inrush current <2ms (cold start)
115 VAC 50 A
230 VAC 75 A
277 VAC 90 A
Leakage current I/O 0.25 mA I/FG, O/FG 3.5 mA Power factor 115 VAC 0.98 230 VAC 0.94 277 VAC 0.92 External fuse Recommended slow blow type 3.5 A Start-up time 900 ms Constant Current or Constant Voltage LED Driver or Converter Over Voltage Protection Over Current Protection Input range 90-305VAC/47-440Hz Waterproof Case rated IP68 High Efficiency up to 89% Power Factor Correction 115VAC Operating temperature -50 to 75°C 230VAC Operating temperature -55 to 75°C Dimmable via resistive 5 Year Limited Warranty Short Circuit Protection Click on Series name for product info on aimtec.com
up to 6.3A | AC-DC / DC-DC | LED Driver / Converter www.aimtec.com Tel: +1 514 620 2722 Toll free: + 1 888 9 AIMTEC (924 6832) F 052.1e R3.Q 2 of 10 North America only Output Specifications Parameters Conditions Typical Maximum Units Current accuracy ±3 % Line regulation LL-HL ±2 % Load regulation 0-100% load ±3 % Ripple & Noise ④ 200 mV p-p Hold-up time (min) 40 ms Current adjustment range⑤ 100-10 % ④ Ripple and Noise are measured at 20MHz bandwidth by using a 0.1μF (M/C) or (C/C) and 47µF (E/C) parallel capacitor. ⑤Note: from 0% to 10% dimming adjustment signal instability may be present. Isolation Specifications Parameters Conditions Typical Maximum Units Tested voltage I/O 3sec 3750 VAC I/FG 2000 VAC O/FG 500 VAC Isolation resistance 500 VDC >1000 MΩ General Specifications Parameters Conditions Typical Maximum Units Switching frequency 100 KHz Over current protection AMER150-50300CAZ 3.07 A AMER150-36420CAZ 4.27 AMER150-24630CAZ 6.37 Over voltage protection Refer to Constant Current vs. Constant Voltage Mode curve Short circuit protection Auto recovery Operating temperature (See Derating Table) (115VAC) -50 to +75 oC (230VAC) -55 to +75 oC Cold Start-up Time -55°C 20 Sec Maximum case temperature 100 oC Storage temperature -55 to +95 oC Temperature coefficient ±0.02 % / oC Cooling Free air convection Humidity 95 % RH Case material Aluminum Potting Epoxy (IP68 rated) Wires UL1015 18AWG Input & 14AWG Output *20CM Weight 900 g MTBF >400,000 hrs (MIL-HDBK-217F at +25°C) Safety Specifications Parameters Agency approvals UL, CE Standards UL8750, UL60950-1, EN55022, class B, EN60529(IP68) Information Technology Equipment EN55022 Class B Harmonic Current Emissions IEC/EN 61000-3-2, Class C Voltage fluctuations and flicker IEC/EN 61000-3-3, (EN60555-3) Electrostatic Discharge Immunity IEC 61000-4-2 Level 3 RF, Electromagnetic Field Immunity IEC 61000-4-3 Level 2 Electrical Fast Transient / Burst Immunity IEC 61000-4-4 Level 2 Surge Immunity IEC 61000-4-5 Level 3 RF, Conducted Disturbance Immunity IEC 61000-4-6 Level 2 Power frequency Magnetic Field Immunity IEC 61000-4-8 Level 1 Voltage dips, Short Interruptions Immunity IEC 61000-4-11
up to 6.3A | AC-DC / DC-DC | LED Driver / Converter www.aimtec.com Tel: +1 514 620 2722 Toll free: + 1 888 9 AIMTEC (924 6832) F 052.1e R3.Q 3 of 10 North America only Dimensions 59.00 (2.32) 181.00 (7.13) 47.00 (1.85) 200.00 (8.00) 200.00 (8.00) 2.30 (0.09) End View Top View Side View Input/Output Wires are 18 AWG 20cm 41.00 (1.73) 8.00 (0.32) 11.00 (0.43) 4.00 (0.16) 23.00 (0.91) Measurements in Millimeters (inch) Case Tolerance: ±0.5 (±0.02) 27.00 (1.06) Wire connection: Analog (resistive) Dimming Application Circuit Wire Connection Brown AC L Blue AC N Green Ground Red +V output Black -V Output Blue (Dimming) + Vs dimming White (Dimming) -Vs dimming Model Number Maximum Pot Value (kΩ) AMER150-50300CAZ 16.71 AMER150-36420CAZ 26.70 AMER150-24630CAZ 11.47
up to 6.3A | AC-DC / DC-DC | LED Driver / Converter www.aimtec.com Tel: +1 514 620 2722 Toll free: + 1 888 9 AIMTEC (924 6832) F 052.1e R3.Q 4 of 10 North America only Analog (0-10V) Dimming Application Circuit PWM (1KHz) Dimming Application Circuit
up to 6.3A | AC-DC / DC-DC | LED Driver / Converter www.aimtec.com Tel: +1 514 620 2722 Toll free: + 1 888 9 AIMTEC (924 6832) F 052.1e R3.Q 5 of 10 North America only Derating Efficiency vs. Input Voltage & Output Current (CC mode) AMER150-50300CAZ 230VAC
up to 6.3A | AC-DC / DC-DC | LED Driver / Converter www.aimtec.com Tel: +1 514 620 2722 Toll free: + 1 888 9 AIMTEC (924 6832) F 052.1e R3.Q 6 of 10 North America only AMER150-36420CAZ AMER150-24630CAZ
up to 6.3A | AC-DC / DC-DC | LED Driver / Converter www.aimtec.com Tel: +1 514 620 2722 Toll free: + 1 888 9 AIMTEC (924 6832) F 052.1e R3.Q 7 of 10 North America only PFC value vs. Output Load Current (CC mode) AMER150-50300CAZ AMER150-36420CAZ
up to 6.3A | AC-DC / DC-DC | LED Driver / Converter www.aimtec.com Tel: +1 514 620 2722 Toll free: + 1 888 9 AIMTEC (924 6832) F 052.1e R3.Q 8 of 10 North America only AMER150-24630CAZ Constant Current vs. Constant Voltage Mode AMER150-50300CAZ
up to 6.3A | AC-DC / DC-DC | LED Driver / Converter www.aimtec.com Tel: +1 514 620 2722 Toll free: + 1 888 9 AIMTEC (924 6832) F 052.1e R3.Q 9 of 10 North America only AMER150-36420CAZ AMER150-24630CAZ
up to 6.3A | AC-DC / DC-DC | LED Driver / Converter www.aimtec.com Tel: +1 514 620 2722 Toll free: + 1 888 9 AIMTEC (924 6832) F 052.1e R3.Q 10 of 10 North America only Output Current vs. Radj AMER150-50300CAZ AMER150-36420CAZ AMER150-24630CAZ NOTE: 1. Datasheets are updated as needed and as such, specifications are subject to change without notice. Once printed or downloaded, datasheets are no longer controlled by Aimtec; refer to www.aimtec.com for the most current product specifications. 2. Product labels shown, including safety agency certifications on labels, may vary based on the date manufactured. 3. Mechanical drawings and specifications are for reference only. 4. All specifications are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at rated output load unless otherwise specified. 5. Aimtec may not have conducted destructive testing or chemical analysis on all internal components and chemicals at the time of publishing this document. CAS numbers and other limited information are considered proprietary and may not be available for release. 6. This product is not designed for use in critical life support systems, equipment used in hazardous environments, nuclear control systems or other such applications which necessitate