AMER120C-70170Z AIMTEC | Alldatasheet

Document overview

  • Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
  • PDF pages: 6

Technical content

up to 1700mA | AC-DC LED driver www.aimtec.com Tel: +1 514 620 2722 Toll free: + 1 888 9 AIMTEC (924 6832) F 052.1e R3 1 of 6 North America only FEATURES: Models Single output Model Max Output Power (W) Input Voltage (VAC/Hz) Output Voltage Range (V) Output Current (A) Efficiency (%) AMER120C-70170Z 119 90-305/47-63 35-70 1.7 91 AMER120C-70170Z-P 119 90-305/47-63 35-70 1.7 90.5 AMER120C-70170Z-PD 119 90-305/47-63 35-70 1.7 90 AMER120C-60200Z 120 90-305/47-63 42-60 2 90 Model Nomenclature functional differences: With Suffix “-PD” With manually adjustable 50-100% & fully dimmable 10-100% (0-10V/10PWM/Resistive) output current With Suffix “-P” Only with manually adjustable output current: 50-100% Without Suffix Only with fully dimmable 10-100% (0-10V/10PWM/Resistive) output current NOTE: All specifications in this datasheet are measured at an ambient temperature of 25°C, humidity <75%, nominal input voltage and at rated output load unless otherwise specified. Input Specifications Parameters Conditions Typical Maximum Units Input Current 90 VAC, full load  1.6 Arms Inrush current <2ms 115 VAC, cold start  45 A 305 VAC, cold start  75 Leakage current  0.75 mA Input dissipation No Load 3.0 W Output Short 10.0 W Power Factor 115 VAC, full load 0.98 277 VAC, full load 0.92 Input Fuse 3.15A / 300V Start-up Time 115 VAC, full load 1.5 Sec. 277 VAC, full load 1.0 Sec. Output Specifications Parameters Conditions Typical Maximum Units Current accuracy ±3 % Line regulation LL to HL ±1 % Load regulation Full Output Voltage Range ±1 % Ripple & Noise 4.5 V p-p Output Current Ripple Full load, 16.7-20ms duration 1.5 A p-p Current Overshoot LL to HL, full load at cold start, % of rated output current 10 % Hold-up time (min.) 0.5 ms Minimum Load Voltage See Models Table Above Isolation Specifications Parameters Conditions Typical Rated Units I/O Isolation Voltage I/P – O/P 3750 VAC I/P – FG 2000 VAC O/P – FG 500 VAC Isolation Resistance I/P – O/P, 500Vdc >100MΩ VAC

  • Accurate Constant Current Output ±3% • IP65/IP67 design for indoor/outdoor
  • High Efficiency: Up to 91% • Over Temperature Protection
  • Active Power Factor Correction • Dimmable output current: 10-100%
  • UVLO, Short Circuit, Over Voltage
  • Adjustable output current: 50-100%
  • Open circuit protection
  • 5 Year Warranty

up to 1700mA | AC-DC LED driver www.aimtec.com Tel: +1 514 620 2722 Toll free: + 1 888 9 AIMTEC (924 6832) F 052.1e R3 2 of 6 North America only Isolation Capacitance 3800 pF General Specifications Parameters Conditions Typical Maximum Units Switching frequency 130 KHz Over Voltage protection 75 V Short circuit protection Continuous, Hiccup mode, auto recovery Open circuit protection Continuous Over Temperature Protection Threshold – Shutdown Output +106 oC Hysteresis – Auto Recovery +90 oC Operating temperature With Derating over 60oC -40 to +70 oC Maximum case temperature 90 oC Warranty case temperature -40 to 73 oC Storage temperature -40 to +85 oC Temperature coefficient 0.03 % / oC Cooling Free Air Convection Humidity 95 % RH Case material Metal (Aluminum) Potting material Polysiloxane IP Rating IP67 Weight 850 g MTBF >400,000 hrs (MIL-HDBK-217F at +25°C) Safety Specifications Parameters Standards Electromagnetic Interference EN55015 / FCC Part 15, Class B Harmonic Current Emissions EN61000-3-2, Class B Voltage fluctuations and flicker EN61000-3-3 Electrostatic Discharge Immunity EN61000-4-2, 8kV Air, 4kV Contact, Level 3, Criteria A RF, Electromagnetic Field Immunity EN61000-4-3, Test-RS Level 3, Criteria A Surge Immunity EN61000-4-5, Line to Neutral 4kV, Line/Neutral to FG 6kV RF, Conducted Disturbance Immunity EN61000-4-6. Test-CS Level 3, Criteria A Power frequency Magnetic Field Immunity EN61000-4-8, Test 3A/m, Criteria A Voltage dips, Short Interruptions Immunity EN61000-4-11, Criteria B Electromagnetic Immunity Requirements Applies to Lighting Equipment EN61547 Pin Definition Block diagram Input wire gauge #18 Output wire gauge #14 Wire Pin Blue AC-N Brown AC-L Yellow/Green FG Red LED+ +V Output Black LED- -V Output Red DIM+ Black DIM- AC 1st LED LED LED LED- AC-L AC-N 0-10V R 10V DIM+ LED+ DIM+AC-N

up to 1700mA | AC-DC LED driver www.aimtec.com Tel: +1 514 620 2722 Toll free: + 1 888 9 AIMTEC (924 6832) F 052.1e R3 3 of 6 North America only Dimensions Top View 68.7±1.0 2.70±0.04 150.0±0.5 5.91±0.02 175.4±1.0 6.91±0.04 159.0±1.0 6.26±0.04 163.0±1.5 6.42±0.06 320.0±20.0 12.60±0.79 5.0±1.0 0.20±0.04 35.0±2.0 1.38±0.08 4.0 0.16 7.4 0.2930.3 1.19 7.4 0.29 4.0 0.16 4.0 0.16 12.7 0.50 12.7 0.50 10.0±1.0 0.39±0.04 320.0±20.0 12.60±0.79 30.0±2.0 1.18±0.08 Side View Yellow/Green Blue Brown 42.0±1.0 1.65±0.0 150.0±0.5 5.91±0.02 175.4±1.0 6.91±0.04 Derating Graph Free Air Convection Safe Operating Area

up to 1700mA | AC-DC LED driver www.aimtec.com Tel: +1 514 620 2722 Toll free: + 1 888 9 AIMTEC (924 6832) F 052.1e R3 4 of 6 North America only Case Temperature (TC ) vs. Life Time Efficiency Vs. Input Voltage & Output Voltage (Constant current mode) 135 180 40 50 60 70 80 90 Lilfe time(Khours) Case temperature (℃) Case temperature vs Life time

up to 1700mA | AC-DC LED driver www.aimtec.com Tel: +1 514 620 2722 Toll free: + 1 888 9 AIMTEC (924 6832) F 052.1e R3 5 of 6 North America only PF vs. Input Voltage & Output Voltage (constant current mode) Output Current vs. Output Voltage

up to 1700mA | AC-DC LED driver www.aimtec.com Tel: +1 514 620 2722 Toll free: + 1 888 9 AIMTEC (924 6832) F 052.1e R3 6 of 6 North America only Output Current vs. Resistive / 0-10V Dimming Output Current vs.10V PWM Dimming NOTE: 1. Datasheets are updated as needed and as such, specifications are subject to change without notice. Once printed or downloaded, datasheets are no longer controlled by Aimtec; refer to www.aimtec.com for the most current product specifications. 2. Product labels shown, including safety agency certifications on labels, may vary based on the date manufactured. 3. Mechanical drawings and specifications are for reference only. 4. All specifications are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at rated output load unless otherwise specified. 5. Aimtec may not have conducted destructive testing or chemical analysis on all internal components and chemicals at the time of publishing this document. CAS numbers and other limited information are considered proprietary a nd may not be available for release. 6. This product is not designed for use in critical life support systems, equipment used in hazardous environments, nuclear control s ystems or other such applications which necessitate 0.00% 10.00% 20.00% 30.00% 40.00% 50.00% 60.00% 70.00% 80.00% 90.00% 100.00% 110.00% 120.00% 0 10 20 30 40 50 60 70 80 90 100 Percentage of rated output current 10V PWM Duty Cycle (%) 115/230/277 VACOutput Current vs. 10V PWM Duty Cycle