up to 5A | AC-DC / DC-DC | LED Driver / Converter www.aimtec.com Tel: +1 514 620 2722 Toll free: + 1 888 9 AIMTEC (924 6832) F 052.1e R3.Q 1 of 10 North America only FEATURES: Models Single output Model Max Output Power (W)① Output Voltage Range (V)③ Output Current (A)③ Input Voltage (VAC/Hz) Input Voltage (VDC) Mode of Operation Efficiency (%) 115 VAC 230 VAC 277 VAC AMER120-50250CAZ 125 36-50 0-2.5 90-305/47-440 130-430 Constant Current 87 88 86 Constant Voltage② 87 88 88 AMER120-36340CAZ 122.4 24-36 0-3.4 90-305/47-440 130-430 Constant Current 87 88 88 Constant Voltage② 87 88 88 AMER120-24500CAZ 120 12-24 0-5 90-305/47-440 130-430 Constant Current 85 86 87 Constant Voltage② 86 86 87 Add Suffix “-F” No dimming option ① Exceeding the maximum output power will permanently damage the converter. ② The dimming feature is not supported when units are used in Constant Voltage mode only, Aimtec suggests to order “-F” No dimming option in the case. ③ In constant current mode output current is maximum shown, in constant voltage mode output voltage is the maximum shown. All models can be ordered with optional North American colour input wires (black (L), white (N), green (GND)). Add “–NA” to part number when ordering. NOTE: Aimtec limited warranty of 5 years is valid based on product operation at datasheet specifications at ambient temperature of 25°C, humidity<75%, nominal input voltage (115/230/277VAC) and at rated output load unless otherwise specified. See http://www.aimtec.com/terms-sale AMER120-CAZ’s AC/DC LED drivers have electrical safeguards designed within to protect it from conventional electrical abnormalities with the levels listed in the safety table. Applications for use within rural agricultural, heavy industrial, and other areas or regions which are prone to ‘dirty’ electrical conditions which would subject any of the above models to excessive voltages surges or spikes, may damage or cause early life failure of product. In this case consideration should be made by the end user to ensure that adequate line or mains surge suppression is installed in front of Aimtec device to ensure the longevity of the products. Failure to identify excessive line surges violations prior to installation may damage sensitive equipment permanently. Input Specifications Parameters Conditions Typical Maximum Units Current (full load)
115 VAC 1800 mA
230 VAC 800 mA
277 VAC 700 mA
Inrush current <2ms (cold start)
115 VAC 45 A
230 VAC 60 A
277 VAC 70 A
Leakage current I/O 0.25 mA I/FG, O/FG 3.5 mA Power factor 115 VAC 0.98 230 VAC 0.94 277 VAC 0.92 External fuse Recommended slow blow type 3 A Start-up time 900 ms Output Specifications Parameters Conditions Typical Maximum Units Current accuracy ±3 % Line regulation LL-HL ±2 %
- Constant Current or Constant Voltage LED Driver or Converter
- Short Circuit Protection
- Over Current Protection
- Input range 90-305VAC/47-440Hz • Waterproof Case rated IP68
- 115VAC Operating temperature -50 to 85°C
- 230VAC Operating temperature -55 to 85°C
- Dimmable via resistive
- 5 Years Limited Warranty
- Power Factor Correction
- High Efficiency up to 88% Click on Series name for product info on aimtec.com
up to 5A | AC-DC / DC-DC | LED Driver / Converter www.aimtec.com Tel: +1 514 620 2722 Toll free: + 1 888 9 AIMTEC (924 6832) F 052.1e R3.Q 2 of 10 North America only Load regulation 0-100% load ±3 % Ripple & Noise ④ 20MHz Bandwidth 150 mV p-p Hold-up time 80 ms Current adjustment range⑤ 100-10 % Minimum Load Voltage See the models table ④Ripple and Noise are measured at 20MHz bandwidth by using a 0.1μF (M/C) or (C/C) and 47µF (E/C) parallel capacitor. ⑤Note: from 0% to 10% dimming adjustment signal instability may be present. Isolation Specifications Parameters Conditions Typical Rated Units Tested voltage I/O 3sec 3750 VAC I/FG 2000 VAC O/FG 500 VAC Isolation resistance 500VDC >1000 MΩ General Specifications Parameters Conditions Typical Maximum Units Switching frequency 125 KHz Over current protection AMER120-50250CAZ 2.57 A AMER120-36340CAZ 3.47 AMER120-24500CAZ 5.07 Over voltage protection Refer to Constant Current vs. Constant Voltage Mode curve Short circuit protection Continuous Short circuit restart Auto recovery Operating temperature (See Derating Table) (115VAC) -50 to +85 oC (230VAC) -55 to +85 oC Cold Start-up Time -55°C 30 Sec Maximum case temperature 100 oC Storage temperature -55 to +95 oC Temperature coefficient ±0.02 % / oC Cooling Free air convection Humidity 95 % RH Case material Aluminum Potting Epoxy (IP68 rated) Wires UL1015 18AWG Input & 14AWG Output *20CM Weight 900 g MTBF >400,000 hrs (MIL-HDBK-217F at +25°C) Safety Specifications Parameters Agency approvals UL, CE Standards UL8750, UL60950-1, EN55022, class B, EN60529(IP68) Information Technology Equipment EN55022 Class B Harmonic Current Emissions IEC/EN 61000-3-2, Class C Voltage fluctuations and flicker IEC/EN 61000-3-3, (EN60555-3) Electrostatic Discharge Immunity IEC 61000-4-2 Level 3 RF, Electromagnetic Field Immunity IEC 61000-4-3 Level 2 Electrical Fast Transient / Burst Immunity IEC 61000-4-4 Level 2 Surge Immunity IEC 61000-4-5 Level 3 RF, Conducted Disturbance Immunity IEC 61000-4-6 Level 2 Power frequency Magnetic Field Immunity IEC 61000-4-8 Level 1 Voltage dips, Short Interruptions Immunity IEC 61000-4-11
up to 5A | AC-DC / DC-DC | LED Driver / Converter www.aimtec.com Tel: +1 514 620 2722 Toll free: + 1 888 9 AIMTEC (924 6832) F 052.1e R3.Q 3 of 10 North America only Dimensions 59.00 (2.32) 181.00 (7.13) 47.00 (1.85) 200.00 (8.00) 200.00 (8.00) 2.30 (0.09) End View Top View Side View Input/Output Wires are 18 AWG 20cm 41.00 (1.73) 8.00 (0.32) 11.00 (0.43) 4.00 (0.16) 23.00 (0.91) Measurements in Millimeters (inch) Case Tolerance: ±0.5 (±0.02) 27.00 (1.06) Tc Wire connection: Analog (resistive) Dimming Application Circuit Wire Connection Brown AC L Blue AC N Green Ground Red +V output Black -V Output Blue (Dimming) + Vs dimming White (Dimming) -Vs dimming Model Number Maximum Pot Value (kΩ) AMER120-50250CAZ 18.22 AMER120-36340CAZ 22.10 AMER120-24500CAZ 34.31 AMER120-AZ N 1st LED +Vout -Vout RED BLACK AC BLUE L BROWN GREEN BLUE WHITE Pot
up to 5A | AC-DC / DC-DC | LED Driver / Converter www.aimtec.com Tel: +1 514 620 2722 Toll free: + 1 888 9 AIMTEC (924 6832) F 052.1e R3.Q 4 of 10 North America only Analog (0-10V) Dimming Application Circuit PWM (1KHz) Dimming Application Circuit Derating -40 -20 0 20 40 60 80 100 100 Free Air Convection 55 º C Safe Operating Area Ambient Temperature º C
up to 5A | AC-DC / DC-DC | LED Driver / Converter www.aimtec.com Tel: +1 514 620 2722 Toll free: + 1 888 9 AIMTEC (924 6832) F 052.1e R3.Q 5 of 10 North America only Efficiency vs. Input Voltage and Output Current (CC Load) AMER120-50250CAZ AMER120-36340CAZ
up to 5A | AC-DC / DC-DC | LED Driver / Converter www.aimtec.com Tel: +1 514 620 2722 Toll free: + 1 888 9 AIMTEC (924 6832) F 052.1e R3.Q 6 of 10 North America only Efficiency vs. Input Voltage and Output Current (CC Load) Continued AMER120-24500CAZ PFC Value vs. Output Load Current (CC Load) AMER120-50250CAZ
up to 5A | AC-DC / DC-DC | LED Driver / Converter www.aimtec.com Tel: +1 514 620 2722 Toll free: + 1 888 9 AIMTEC (924 6832) F 052.1e R3.Q 7 of 10 North America only PFC Value vs. Output Load Current (CC Load) AMER120-36340CAZ AMER120-24500CAZ
up to 5A | AC-DC / DC-DC | LED Driver / Converter www.aimtec.com Tel: +1 514 620 2722 Toll free: + 1 888 9 AIMTEC (924 6832) F 052.1e R3.Q 8 of 10 North America only Constant Current Mode vs. Constant Voltage Mode AMER120-50250CAZ AMER120-36340CAZ
up to 5A | AC-DC / DC-DC | LED Driver / Converter www.aimtec.com Tel: +1 514 620 2722 Toll free: + 1 888 9 AIMTEC (924 6832) F 052.1e R3.Q 9 of 10 North America only Constant Current Mode vs. Constant Voltage Mode AMER120-24500CAZ Output Current vs. Radj AMER120-50250CAZ
up to 5A | AC-DC / DC-DC | LED Driver / Converter www.aimtec.com Tel: +1 514 620 2722 Toll free: + 1 888 9 AIMTEC (924 6832) F 052.1e R3.Q 10 of 10 North America only Output Current vs. Radj AMER120-36340CAZ AMER120-24500CAZ NOTE: 1. Datasheets are updated as needed and as such, specifications are subject to change without notice. Once printed or downloaded, datasheets are no longer controlled by Aimtec; refer to www.aimtec.com for the most current product specifications. 2. Product labels shown, including safety agency certifications on labels, may vary based on the date manufactured. 3. Mechanical drawings and specifications are for reference only. 4. All specifications are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at rated output load unless otherwise specified. 5. Aimtec may not have conducted destructive testing or chemical analysis on all internal components and chemicals at the time of publishing this document. CAS numbers and other limited information are considered proprietary a nd may not be available for release. 6. This product is not designed for use in critical life support systems, equipment used in hazardous environments, nuclear control s ystems or other such applications which necessitate