up to 1000mA | AC-DC LED driver www.aimtec.com Tel: +1 514 620 2722 Toll free: + 1 888 9 AIMTEC (924 6832) F 052.1e R3 1 of 4 North America only Picture Coming Soon FEATURES: Models Single output Model Max Output Power (W) Output Voltage Range (V) Output Current (mA) Input Voltage (VAC/Hz) Efficiency (%) AMEQR50N-50100Z 50 36-50 1000 90-305/47-63 88.0 NOTE: All specifications in this datasheet are measured at an ambient temperature of 25°C, humidity <75%, nominal input voltage and at rated output load unless otherwise specified. Input Specifications Parameters Conditions Typical Maximum Units Input Current 90 VAC, full load 0.80 Arms Inrush current <2ms 115 VAC, cold start 40 A 230 VAC, cold start 60 Leakage current 0.75 mA Input dissipation No Load 1.5 W Output Short 4.5 W Power Factor 115 VAC, full load 0.98 230 VAC, full load 0.95 Input Fuse 2.0A / 300V Start-up Time 115 VAC, full load 1.5 Sec. 230 VAC, full load 1.0 Sec. Output Specifications Parameters Conditions Typical Maximum Units Current accuracy ±5 % Line regulation LL to HL ±3 % Load regulation Full Output Voltage Range ±5 % Ripple & Noise 200 mV p-p Output Current Ripple Full load 50 mA Current Overshoot LL to HL, full load at cold start, % of rated output current 15 % Hold-up time (min) 0.5 ms Current adjustment range NA NA % Minimum Load Voltage See Models Table Above Isolation Specifications Parameters Conditions Typical Rated Units Tested I/O voltage I/P – O/P 3750 VAC I/P – FG 2000 VAC O/P – FG 500 VAC Isolation Resistance 500Vdc >100 MΩ Isolation Capacitance 3000 pF General Specifications Parameters Conditions Typical Maximum Units Switching frequency 150 KHz Over voltage protection 63 V
- Universal Input: 90~305 VAC • IP65/67 Design for outdoor application
- High Efficiency: Up to 88% • Long Life, High reliability
- Active Power Factor Correction • Ultra-low ripple without flickering
- Short Circuit / Open Circuit Protection • 5-year limited warranty
up to 1000mA | AC-DC LED driver www.aimtec.com Tel: +1 514 620 2722 Toll free: + 1 888 9 AIMTEC (924 6832) F 052.1e R3 2 of 4 North America only Short circuit protection Continuous, Hiccup Mode Short circuit restart Auto Recovery Open circuit protection Continuous, Hiccup Mode Operating temperature Without Derating -40 to +60 oC Maximum case temperature 90 oC Storage temperature -40 to +85 oC Temperature coefficient 0.03 % / oC Cooling Free Air Convection Humidity 90 % RH Case material Metal (Aluminum) IP Rating IP67 Weight 750 g MTBF > 400,000 hrs (MIL-HDBK-217F at +25°C) Safety Specifications Parameters Standards Electromagnetic Interference EN55015 / FCC Part 15, Class B Harmonic Current Emissions EN61000-3-2, Class B Voltage fluctuations and flicker EN61000-3-3 Electrostatic Discharge Immunity EN61000-4-2, 8kV Air, 4kV Contact, Level 3, Criteria A RF, Electromagnetic Field Immunity EN61000-4-3, Test-RS Level 3, Criteria A Surge Immunity EN61000-4-5, Line to Neutral 4kV, Neutral to FG 6kV RF, Conducted Disturbance Immunity EN61000-4-6. Test-CS Level 3, Criteria A Power frequency Magnetic Field Immunity EN61000-4-8, Test 3A/m, Criteria A Voltage dips, Short Interruptions Immunity EN61000-4-11, Criteria B Electromagnetic Immunity Requirements Applies to Lighting Equipment EN61547 Pin Definition Input Wire specifications: H05RN-F 0.75mm2 Output Wire specifications: H05RN-F 1.0mm2 Wire Pin Blue AC N Brown AC L Yellow/Green FG Red +V Output Black -V Output
up to 1000mA | AC-DC LED driver www.aimtec.com Tel: +1 514 620 2722 Toll free: + 1 888 9 AIMTEC (924 6832) F 052.1e R3 3 of 4 North America only Dimensions Left View Top View 90.0±0.30 3.54±0.01 17.0 0.67 17.0 0.67 90.6±0.30 3.57±0.01 8.00 0.31 5.00 0.20 7.70 0.30 260±20 10.24±0.08 20.0 0.79 5.0±1.0 0.20±0.04 45.3 1.78 45.3 1.78 R5.00X4 0.20X4 Side View 44.5±0.30 1.75±0.01 Application circuit 44.5±0.3 1.75±0.01 AC_L AC_N LED+ LED- AC FG
up to 1000mA | AC-DC LED driver www.aimtec.com Tel: +1 514 620 2722 Toll free: + 1 888 9 AIMTEC (924 6832) F 052.1e R3 4 of 4 North America only Efficiency Vs. Input Voltage & Output Current (Constant current load) PF Vs. Input Voltage & Output Current (Constant current load) NOTE: 1. Datasheets are updated as needed and as such, specifications are subject to change without notice. Once printed or downloaded, datasheets are no longer controlled by Aimtec; refer to www.aimtec.com for the most current product specifications. 2. Product labels shown, including safety agency certifications on labels, may vary based on the date manufactured. 3. Mechanical drawings and specifications are for reference only. 4. All specifications are measured at an ambient temperature of 25°C, humidi ty<75%, nominal input voltage and at rated output load unless otherwise specified. 5.Aimtec may not have conducted destructive testing or chemical analysis on all internal components and chemicals at the time of publishing this document. CAS numbers and other limited information are considered proprietary a nd may not be available for release. 6. This product is not designed for use in critical life support systems, equipment used in hazardous environments, nuclear control systems or other such applications which necessitate 65.00% 70.00% 75.00% 80.00% 85.00% 90.00% 95.00% 36 38 40 42 44 46 48 50 Efficiency Output Voltage(V)
115 VAC
230 VAC
277 VAC
0.000 0.300 0.600 0.900 1.200 36 38 40 42 44 46 48 50 PF Output Voltage(V)