AME5-VZ AIMTEC | Alldatasheet

Document overview

  • Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
  • PDF pages: 3

Technical content

5 Watt | AC-DC / DC-DC Converter

www.aimtec.com Tel: +1 514 620 2722 Toll free: + 1 888 9 AIMTEC (924 6832) F 052e R8.B 1 of 3 North America only Picture coming soon FEATURES: Models Single output Model Input Voltage (VAC/Hz) Input Voltage (VDC) Output Voltage (V) Output Current max (A) Maximum capacitive Load (µF) Efficiency 230VAC (%) AME5-3.3SVZ 85-264/47-63 100-370 3.3 1.25 8100 70 AME5-5SVZ 85-264/47-63 100-370 5 1 6800 75 AME5-9SVZ 85-264/47-63 100-370 9 0.55 1200 77 AME5-12SVZ 85-264/47-63 100-370 12 0.42 1000 79 AME5-15SVZ 85-264/47-63 100-370 15 0.330 680 80 AME5-24SVZ 85-264/47-63 100-370 24 0.23 270 82 Input Specifications Parameters Conditions Typical Maximum Units Current (full load) 115 VAC  125 mA

230 VAC  80 mA

Inrush current <2ms (cold start) 115 VAC 10 A

230 VAC 20 A

Leakage current 230VAC/50Hz  0.3 mA External fuse Recommended slow blow type 1 A Output Specifications Parameters Conditions Typical Maximum Units Voltage accuracy ±2 % Line regulation Full load ±0.5 % Load regulation (single output) 0%-100% load ±1 % Minimum load Single output 0 % Ripple & Noise * 50 150 mV p-p Hold-up time 115VAC, 20MHz bandwidth 15 ms 230VAC, 20MHz bandwidth 80 ms Isolation Specifications Parameters Conditions Typical Rated Units Tested I/O voltage 60 sec 4000 VAC Isolation Resistance >1000 MΩ General Specifications Parameters Conditions Typical Maximum Units Protection class Class I Over current protection 150-300 % of Iout Over voltage protection Zener diode clamp Short circuit protection Continuous, Auto recovery Operating temperature See derating curve -40 to +85 oC Storage temperature -40 to +105 oC Temperature coefficient ±0.02 % / oC Cooling Free air convection

  • I/O Isolation 4000VAC • Continuous Short circuit protection
  • Operating Temp: -40 °C to +85 °C • Regulated Output
  • Input: 85-264VAC, 47-63Hz, or 100-370VDC • Compact package
  • Over current, Over Voltage Protection • Efficiency up to 82% Click on Series name for product info on aimtec.com

www.aimtec.com Tel: +1 514 620 2722 Toll free: + 1 888 9 AIMTEC (924 6832) F 052e R8.B 2 of 3 North America only Humidity Non condensing 95 % RH Case material Plastic (flammability to UL 94V-0) Weight 55 g MTBF > 300,000 hrs (MIL-HDBK -217F, t=+25oC)/Full Load NOTE: All specifications in this datasheet are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at rated output load unless otherwise specified. Safety Specifications Parameters Agency approvals Designed to meet UL62368 Standards Designed to meet IEC/EN/UL 62368-1 EMI - Conducted and radiated emission EN55032, class B Electrostatic Discharge Immunity IEC 61000-4-2, Contact: ±6KV/Air: ±8KV, Criteria B RF, Electromagnetic Field Immunity IEC 61000-4-3, 10V/m, Criteria A Electrical Fast Transient/Burst Immunity IEC 61000-4-4, ±2KV, Criteria B IEC 61000-4-4, ±4KV, Criteria B with EMC recommended circuit Surge Immunity IEC 61000-4-5, ±1KV Criteria B IEC 61000-4-5, ±2KV, Criteria B with EMC recommended circuit RF, Conducted Disturbance Immunity IEC 61000-4-6, 10Vrms, Criteria A Voltage dips, Short Interruptions Immunity IEC 61000-4-11, 0-70%, Criteria B Dimensions Pin Out Specifications Pin Single

1 Ground

2 AC Input (N)

3 AC Input (L)

5 No pin

6 No pin

7 No pin

48.50 (1.91) 36.00 (1.42) Bottom View 5.50 (0.22) 4.00 (0.16) 4.00 (0.16) 40.50 (1.59) 6.00 (0.24) 1.00 (0.04) 12.50 (0.49) 10.00 (0.39) 20.50 (0.81) Case Tolerance ±0.50 (±0.02) Pin Diameter 1.0 ± 0.10 (0.04 ± 0.004) Dimensions mm (inch) Ø 1.50 (Ø 0.06) DIV: 10.00 (0.40) Top View 2 6 4.00 (0.16)

www.aimtec.com Tel: +1 514 620 2722 Toll free: + 1 888 9 AIMTEC (924 6832) F 052e R8.B 3 of 3 North America only Derating Typical application circuit EMC recommended circuit NOTE: 1. Datasheets are updated as needed and as such, specifications are subject to change without notice. Once printed or downloaded, datasheets are no longer controlled by Aimtec; refer to www.aimtec.com for the most current product specifications. 2. Product labels shown, including safety agency certifications on labels, may vary based on the date manufactured. 3. Mechanical drawings and specifications are for reference only. 4. All specifications are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at rated output load unless otherwise specified. 5. Aimtec may not have conducted destructive testing or chemical analysis on all internal components and chemicals at the time of publishing this document. CAS numbers and other limited information are considered proprietary and may not be available for release. 6. This product is not designed for use in critical life support systems, equipment used in hazardous environments, nuclear control s ystems or other such applications which necessitate Model C2 TVS 3.3 & 5 Vout 330 µF / 35V 7V

9 Vout 120 µF / 35V 12V

12 Vout 120 µF / 35V 20V

15 Vout 68 µF / 35V 20V

24 Vout 68 µF / 35V 30V

(100) 100 (120) 264 (350) 100 Safe Operating Area Output Power (%) Free Air Convection at 25°C Input Voltage VAC (VDC) 240 (320) -20 0 20 40 60 80 100 Safe Operating Area Input 85-264VAC or 100-370VDC - 25 Free Air Convection Ambient Temperature º C 8555 -10 -40 AC DC AC L AC N + Vout - Vout Single Output MOV S14K350 FUSE 1A/250V 1µF/50V AC L AC N + Vout - Vout + TVS Ground AC DC AC L AC N LDM 4.7µH/2A +Vout - Vout Single Output MOV S14K350 FUSE 2A/250V AC N AC L C2 + LCM 10mH CX 0.1µF/ 275VAC GND CY1 1nF/ 400VAC CY2 1nF/ 400VAC 1µF/50V +Vout - Vout TVS