3 Watt | AC-DC / DC-DC Converter
www.aimtec.com Tel: +1 514 620 2722 Toll free: + 1 888 9 AIMTEC (924 6832) F 052e R1 1 of 4 North America only FEATURES: Models Single output Model Input Voltage (VAC/Hz) Input Voltage (VDC) Temperature range (ºC) Output Voltage (V) Output Current max (mA) Maximum capacitive Load (µF) Efficiency (%) 230 VAC AME3-3.3SBJZ 90-528/47-63 100-745 -40 to +70 3.3 500 2200 63 AME3-5SBJZ 90-528/47-63 100-745 -40 to +70 5 500 1100 70 AME3-9SBJZ 90-528/47-63 100-745 -40 to +70 9 333 680 73 AME3-12SBJZ 90-528/47-63 100-745 -40 to +70 12 250 680 76 AME3-15SBJZ 90-528/47-63 100-745 -40 to +70 15 200 560 76 AME3-24SBJZ 90-528/47-63 100-745 -40 to +70 24 125 470 76 Input Specifications Parameters Conditions Typical Maximum Units Current (full load)
115 VAC 120
480 VAC 40
Inrush current <2ms (cold start)
115 VAC 9
480 VAC 27
Leakage current 230VAC/50Hz, rms 0.25 mA External fuse Recommended slow blow type 2 A Output Specifications Parameters Conditions Typical Maximum Units Voltage accuracy 3.3V output ±6 % Others ±5 Line regulation LL-HL, Full Load, 3.3V output ±2.5 % LL-HL, Full Load, Others ±1.5 Load regulation 10% - 100% load, nominal input ±2.5 % Ripple & Noise* 20MHz bandwidth, 115/230VAC, Full Load 180 mV p-p Hold up time 230VAC 40 ms *With output filter capacitors referenced in the application circuit. Isolation Specifications Parameters Conditions Typical Rated Units Tested I/O voltage 60 sec 3000 VAC Isolation Resistance >1000 MΩ General Specifications Parameters Conditions Typical Maximum Units Switching frequency 65 KHz Over Current protection Auto recovery 150-300 % of Iout No load consumption 230VAC 0.3 W 528VAC 0.5 Short circuit protection Auto recovery, Continuous Operating temperature See derating curve -40 to +70 °C Storage temperature -40 to +105 °C Temperature coefficient ±0.15 %/°C Maximum Case temperature 95 °C Humidity Non-condensing 85 % RH
- I/O Isolation 3000VAC • Class II Power supply
- Operating Temp: -40°C to +70°C
- Input 90-528VAC, 47-63Hz, or 100-745 VDC
- Over current Protection
- Low no load consumption ≤ 0.5W
- Continuous Short Circuit Protection Click on Series name for product info on aimtec.com
www.aimtec.com Tel: +1 514 620 2722 Toll free: + 1 888 9 AIMTEC (924 6832) F 052e R1 2 of 4 North America only Case material Plastic resin (flammability to UL 94V-0) Weight 30 g Cooling Free air convection MTBF > 300,000 hrs (MIL-HDBK -217F, t=+25°C) at Full Load NOTE: All specifications in this datasheet are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at rated output load unless otherwise specified. Safety Specifications Parameters Standards Information technology Equipment Meets IEC/EN/UL 60950-1 EMI - Conducted and radiated emission EN55022, class A; class B with the recommended EMC circuit Electrostatic Discharge Immunity IEC 61000-4-2, Contact: ±6KV/Air: ±8KV, Criteria B RF, Electromagnetic Field Immunity IEC 61000-4-3, 10V/m, Criteria A with the recommended EMC circuit Electrical Fast Transient/Burst Immunity IEC 61000-4-4, ±2KV; ±4KV with the recommended EMC circuit, Criteria B Surge Immunity IEC 61000-4-5, ±1KV; ±2KV with the recommended EMC circuit, Criteria B RF, Conducted Disturbance Immunity IEC 61000-4-6, 3Vrms, Criteria A with the recommended EMC circuit Voltage dips, Short Interruptions Immunity IEC 61000-4-11, 0-70%, Criteria B with the recommended EMC circuit Dimensions Pin Out Specifications * Note: Input Pins 1 and 2 can be “N” and "L" respectively when the input voltage is supplied from a single phase. Input Pins 1 and 2 can be “L1” and "L2" respectively when the input voltage is supplied from 3 phase line to line voltage 208-480Vac (208 Y/ 120V 3-phase, 240 Y/ 120V 3-phase, 400 Y/ 230V 3-phase or 480 Y/ 277V 3-phase). Pin Single 1* AC Input (N) or (L1) 2* AC Input (L) or (L2) 3 +V Output 4 -V Output TOP VIEW1 Dimensions: inch (mm) Case Tolerance:± 0.50 (0.02) Pin Pitch Tolerance: ± 0.10 (0.004) 25.40 (1.00) 10.16 (0.40) 50.80 (2.00) 45.72 (1.80) 20.32 (0.80) TOP VIEW 15.16 (0.60) Ø 1.00 (0.04) Case Temperature Measurement point 6.00 (0.24)
www.aimtec.com Tel: +1 514 620 2722 Toll free: + 1 888 9 AIMTEC (924 6832) F 052e R1 3 of 4 North America only Derating - 40 -20 0 20 40 60 80 100 100 Safe Operating Area 100% load 90-165VAC Or 100-230VDC Output Power (%) Ambient Temperature º C Free Air Convection 55 70 - 40 -20 0 20 40 60 80 100 100 Safe Operating Area 165-528VAC 230-745VDC Output Power (%) Ambient Temperature º C Free Air Convection 55 70 Application circuit *GND connection not allowed AC DC AC L AC N + Vout - Vout Single Output MOV S14K550 FUSE 100nF/50V AC L AC N C2 + TVS (100) 110 (155) 528 (745) 100 Safe Operating Area Output Power (%) Free Air Convection at 25°C Input Voltage VAC (VDC) 480 (675)
www.aimtec.com Tel: +1 514 620 2722 Toll free: + 1 888 9 AIMTEC (924 6832) F 052e R1 4 of 4 North America only Class B compliance recommended circuit AC DC AC L AC N +Vout - Vout Single Output MOV 1 S14K550 FUSE 100nF/ 50V C2 + TVSLCM 10mH MOV 2 S07K300 MOV 3 S07K300 CX 220nF/ 530VAC CY1 470pF/ 500VAC CY2 470pF/ 500VAC 12 /2W GND 12 /2W AC L AC N +Vout - Vout NOTE: 1. Datasheets are updated as needed and as such, specifications are subject to change without notice. Once printed or downloaded, datasheets are no longer controlled by Aimtec; refer to www.aimtec.com for the most current product specifications. 2. Product labels shown, including safety agency certifications on labels, may vary based on the date manufactured. 3. Mechanical drawings and specifications are for reference only. 4. All specifications are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at rated output load unless otherwise specified. 5. Aimtec may not have conducted destructive testing or chemical analysis on all internal components and chemicals at the time of publishing this document. CAS numbers and other limited information are considered proprietary and may not be available for release. 6. This product is not designed for use in critical life support systems, equipment used in hazardous environments, nuclear control s ystems or other such applications which necessitate Model C2 TVS
3.3 Vout 100 µF / 16V 7V
5 Vout 47 µF / 16V 7V
9 Vout
47 µF / 35V 12V 12 & 15 Vout 20V