Technical content
3Watt | AC-DC Converter www.aimtec.com Tel: +1 514 620 2722 Toll free: + 1 888 9 AIMTEC (924 6832) F 052e R8.B 1 of 3 North America only FEATURES: Models Single output Model Input Voltage (VAC/Hz) Input Voltage (VDC) Temperature range (ºC) Output Voltage (V) Output Current max (mA) Maximum capacitive Load (µF) Efficiency (%) 115 VAC 230 VAC 277 VAC 480 VAC AME3-3.3SAZ 90-305/47-440 130-430 -40 to +80 3.3 900 2200 63 64 62 AME3-5SAZ 90-305/47-440 130-430 -40 to +80 5 600 1100 67 67 65 AME3-12SAZ 90-305/47-440 130-430 -40 to +80 12 250 680 75 73 70 AME3-15SAZ 90-305/47-440 130-430 -40 to +80 15 200 560 78 74 71 AME3-24SAZ 90-305/47-440 130-430 -40 to +80 24 125 470 81 81 80 AME3-3.3SBAZ 90-528/47-440 130-745 -40 to +80 3.3 700 2200 61 61 60 54 AME3-5SBAZ 90-528/47-440 130-745 -40 to +80 5 600 1100 67 67 66 60 AME3-12SBAZ 90-528/47-440 130-745 -40 to +80 12 250 680 72 72 70 61 AME3-15SBAZ 90-528/47-440 130-745 -40 to +80 15 200 560 72 71 70 61 AME3-24SBAZ 90-528/47-440 130-745 -40 to +80 24 125 470 71 71 69 62 Input Specifications Parameters Conditions Typical Maximum Units Current (full load)
115 VAC 80 mA
230 VAC 40 mA
277 VAC 35 mA
Inrush current <2ms (cold start)
115 VAC 10 A
230 VAC 15 A
277 VAC 20 A
480 VAC 30 A
Leakage current 0.15 mA External fuse Recommended slow blow type 1 A Input Dissipation (No Load) ≦0.5 W Output Specifications Parameters Conditions Typical Maximum Units Voltage accuracy Full load (typical)* ±5 % Line regulation LL-HL, Full Load ±1.5 % Load regulation (single output) 0-100% load (typical)* ±5 % Transient Recovery Time 200 µs Transient Response Deviation 25% load step ±2 % of Vout Minimum load 0 % Ripple & Noise 3.3/5 VAC With 560µF E/C 200 mV p-p 12/15 VAC With 220µF E/C 400 mV p-p
24 VAC With 220µF E/C 500 mV p-p
*Ripple & Noisemeasured at 20MHz bandwidth with 0.1µFand 115/230/277/480VAC( Typical input ) with Full Load Isolation Specifications Parameters Conditions Typical Rated Units Tested I/O voltage 60 sec 3000 VAC Isolation Resistance >1000 MΩ General Specifications Parameters Conditions Typical Maximum Units Switching frequency 100 KHz Over Load protection Auto recovery >125% Short circuit protection Auto recovery
- I/O Isolation 3000VAC • RoHS compliant
- Operating Temp: -40oCto +80oC
- Over load, Short Circuit Protection
- Energy Star compliant
- Ultra small package
- Input: 90-305VAC, 47-440Hz, or 130-430 VDC
- Optional 90-528VAC, 47-440Hz, or 130-745 VDC Click on Series name for product info on aimtec.com
3Watt | AC-DC Converter www.aimtec.com Tel: +1 514 620 2722 Toll free: + 1 888 9 AIMTEC (924 6832) F 052e R8.B 2 of 3 North America only General Specifications (continued) Parameters Conditions Typical Maximum Units Operating temperature See deratingchart -40 to +80 o C Storage temperature -40 to +85 o C Maximum Case temperature 100 o C Humidity Non condensing 20~95 % RH Case material Plastic resin + Fiberglass (flammability to UL 94V-0) Weight 25 g MTBF > 400 000 hrs (MIL-HDBK -217F, t=+25 o C)/Full Load > 100,000 hrs (MIL-HDBK -217F, t= at highest operating temperature)/Full Load NOTE: All specifications in this datasheet are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at rated output load unless otherwise specified. Environment Approval Parameters Conditions Shock Wave form: Half sine wave Acceleration amplitude: 5gn Bump duration: 30 ms Number of bumps: 18 (3 in each direction for every axis) Converter operation before and after test, body mounted (on chassis) Vibrations Test mode: Sweep sine 10-100Hz, speed 0.05Hz/s Displacement: 1mm Acceleration: 3g 3 loops 30min one cycle, 3h total, every axis tested Converter operation before and after test, body mounted (on chassis) Safety Specifications Parameters Agency approvals cULus, CE, CB (pending), CSA Information technology Equipment IEC/EN/UL 60950-1:2006+A11:2009 EMI - Conducted and radiated emission EN55022, class B Harmonic Current Emissions IEC/EN 61000-3-2, (EN60555-2) Voltage fluctuations and flicker IEC/EN 61000-3-3, (EN60555-3) Electrostatic Discharge Immunity IEC 61000-4-2 RF, Electromagnetic Field Immunity IEC 61000-4-3 Electrical Fast Transient/Burst Immunity IEC 61000-4-4 Surge Immunity (1KV) IEC 61000-4-5(SAZ:Level2,SBAZ:Level 1) RF, Conducted Disturbance Immunity IEC 61000-4-6 Power frequency Magnetic Field Immunity IEC 61000-4-8 Voltage dips, Short Interruptions Immunity IEC 61000-4-11 Canadian Safety Agency CAN/CSA-C22.2 NO. 60950-1-07 Derating 0 20 6040 80 100 Safe Operating Area Free Air Convection Ambient Temperature º C 100-40 Output Power % -25 ºC55
3Watt | AC-DC Converter www.aimtec.com Tel: +1 514 620 2722 Toll free: + 1 888 9 AIMTEC (924 6832) F 052e R8.B 3 of 3 North America only Pin Out Specifications Dimensions NOTE: 1. Datasheets are updated as needed and as such, specifications are subject to change without notice. Once printed or downloaded, datasheets are no longer controlled by Aimtec; refer to www.aimtec.com for the most current product specifications. 2. Product labels shown, including safety agency certifications on labels, may vary based on the date manufactured. 3.Mechanical drawings and specifications are for reference only. 4.All specifications are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at rated output load unless otherwise specified. 5.Aimtec may not have conducted destructive testing or chemical analysis on all internal components and chemicals at the time of publishing this document. CAS numbers and other limited information are considered proprietary and may not be available for release. 6. This product is not designed for use in critical life support systems, equipment used in hazardous environments, nuclear control systems or other such applications which necessitate Pin Single