DATASHEET SEARCH SITE | WWW.ALLDATASHEET.COM

Document overview

  • Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
  • PDF pages: 5

Technical content

25 Watt | AC-DC / DC-DC Converter

www.aimtec.com Tel: +1 514 620 2722 Toll free: + 1 888 9 AIMTEC (924 6832) F 052e R8.A 1 of 5 North America only Picture coming soon FEATURES: Models Single output Model Input Voltage (VAC/Hz) Input Voltage (VDC) Output Voltage (V) Output Current max (A) Maximum capacitive Load (µF) Efficiency 230VAC (%) AME25-3.3SCJZ 85-264/47-63 120-370 3.3 4.1 48000 73 AME25-5SCJZ 85-264/47-63 120-370 5 4.1 12240 74 AME25-9SCJZ 85-264/47-63 120-370 9 2.5 5600 78 AME25-12SCJZ 85-264/47-63 120-370 12 2.1 5400 82 AME25-15SCJZ 85-264/47-63 120-370 15 1.6 2400 83 AME25-24SCJZ 85-264/47-63 120-370 24 1.1 1440 85 AME25-48SCJZ 85-264/47-63 120-370 48 0.5 500 87 Input Specifications Parameters Conditions Typical Maximum Units Current (full load) 115 VAC  600 mA

230 VAC  340 mA

Inrush current <2ms (cold start) 115 VAC 16 A

230 VAC 30 A

Leakage current 230VAC/50Hz  0.3 mA External fuse Recommended slow blow type 3.15 A Output Specifications Parameters Conditions Typical Maximum Units Voltage accuracy ±2 % Line regulation Full load, main output ±0.5 % Full load, auxiliary output ±1.5 % Load regulation (single output) 10-100% load ±1 % Load Regulation (dual output) 10-100% Balanced load ±2 % Load Regulation (triple & asymmetric separated output) 10-100% Balanced load, main output ±3 10-100% Balanced load, auxiliary output ±5 Minimum load Single output 0 % Others 10 % Ripple & Noise * 50 150 mV p-p Hold-up time 115VAC, 20MHz bandwidth 15 ms 230VAC, 20MHz bandwidth 80 ms Voltage adjustment range ±10 % of Vout Isolation Specifications Parameters Conditions Typical Rated Units Tested I/O voltage 60 sec 3000 VAC Isolation voltage between Main and Auxiliary output 60 sec 500 VDC Isolation Resistance >1000 MΩ  I/O Isolation 3000VAC  Continuous Short circuit protection  Operating Temp: -25 °C to +70 °C  Energy Star compliant  Input: 85-264VAC, 47-63Hz, or 120-370VDC  Compact package  Over current, Over Voltage Protection  Efficiency up to 87% Click on Series name for product info on aimtec.com

www.aimtec.com Tel: +1 514 620 2722 Toll free: + 1 888 9 AIMTEC (924 6832) F 052e R8.A 2 of 5 North America only General Specifications Parameters Conditions Typical Maximum Units Switching frequency 100% load 65 KHz Protection class Class I Over current protection ≥110 % of Iout Over voltage protection Zener diode clamp Short circuit protection Continuous, Auto recovery Operating temperature See derating curve -25 to +70 oC Storage temperature -25 to +105 oC Maximum Case temperature 100 oC Temperature coefficient ±0.02 % / oC Cooling Free air convection Humidity Non condensing 95 % RH Case material Plastic (flammability to UL 94V-0) Weight 120 g MTBF > 300,000 hrs (MIL-HDBK -217F, t=+25oC)/Full Load NOTE: All specifications in this datasheet are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at rated output load unless otherwise specified. Safety Specifications Parameters Agency approvals cULus, CE Standards Information technology Equipment IEC/EN/UL 60950-1 EMI - Conducted and radiated emission EN55022, class B Electrostatic Discharge Immunity IEC 61000-4-2 Level 3 RF, Electromagnetic Field Immunity IEC 61000-4-3 Level 3 Electrical Fast Transient/Burst Immunity IEC 61000-4-4 Level 3 Surge Immunity IEC 61000-4-5 Level 3 RF, Conducted Disturbance Immunity IEC 61000-4-6 Level 3 Power frequency Magnetic Field Immunity IEC 61000-4-8 Level 3 Voltage dips, Short Interruptions Immunity IEC 61000-4-11 Class 2 Dimensions 70.00 (2.76) 48.00 (1.89) Bottom View 4.00 (0.16) 4.00 (0.16) 4.00 (0.16) 62.00 (2.44) 6.00 (0.24) 1.00 (0.04) 20.00 (0.79) 12.50 (0.49) 23.50 (0.93) Case Tolerance ±0.50 (±0.02) Pin Diameter 1.0 ± 0.10 (0.04 ± 0.004) Dimensions mm (inch) Ø 1.50 (Ø 0.06) DIV: 10.00 (0.40) Top View 5.75 (0.23)

www.aimtec.com Tel: +1 514 620 2722 Toll free: + 1 888 9 AIMTEC (924 6832) F 052e R8.A 3 of 5 North America only Pin Out Specifications Derating Typical application circuits Pin Single

1 Ground

2 AC Input (N)

3 AC Input (L)

4 Trim

6 No pin

7 No pin

8 No pin

Single 3.3 & 5 Vout 330 µF 7V Single 9 Vout 330 µF 12V Single 12 & 15 Vout 330 µF 20V Single 24 Vout 120 µF 30V Single 48 Vout 68 µF 64V -20 02 0 4 0 6 0 8 0 100 100 Safe Operating Area Input 100-240VAC or 120-340VDC -2 5 Free Air Convection Ambient Temperature º C 7055 Output power (%) -10 85 (100) 100 (120) 264 (350) 100 Safe Operating Area Output Power (%) Free Air Convection at 25°C Input Voltage VAC (VDC) 240 (320) AC DC AC L AC N + Vout ‐ Vout Single Output MOV S14K350 FUSE 3.15A/300V 1µF/50V NTC AC L AC N + Vout ‐ Vout + TVS Earth/GND

www.aimtec.com Tel: +1 514 620 2722 Toll free: + 1 888 9 AIMTEC (924 6832) F 052e R8.A 4 of 5 North America only Trimming Output voltage can be externally trimmed by utilizing the methods as shown below Fixed Resistor Variable Potentiometer Leave open if not used. AME20‐3.3SCJZ Trim down % 1 2 3 4 5 6 7 8 9 10 Trim up % 1 2 3 4 5 6 7 8 9 10 AME20‐5SCJZ Trim down % 1 2 3 4 5 6 7 8 9 10 Trim up % 1 2 3 4 5 6 7 8 9 10 AME20‐9SCJZ Trim down % 1 2 3 4 5 6 7 8 9 10 Trim up % 1 2 3 4 5 6 7 8 9 10

www.aimtec.com Tel: +1 514 620 2722 Toll free: + 1 888 9 AIMTEC (924 6832) F 052e R8.A 5 of 5 North America only AME20‐12SCJZ Trim down % 1 2 3 4 5 6 7 8 9 10 Trim up % 1 2 3 4 5 6 7 8 9 10 AME20‐15SCJZ Trim down % 1 2 3 4 5 6 7 8 9 10 Trim up % 1 2 3 4 5 6 7 8 9 10 AME20‐24SCJZ Trim down % 1 2 3 4 5 6 7 8 9 10 Trim up % 1 2 3 4 5 6 7 8 9 10 AME20‐48SCJZ Trim down % 1 2 3 4 5 6 7 8 9 10 Trim up % 1 2 3 4 5 6 7 8 9 10 NOTE: 1. Datasheets are updated as needed and as such, specifications are subject to change without notice. Once printed or downloaded, datasheets are no longer controlled by Aimtec; refer to www.aimtec.com for the most current product specifications. 2. Product labels shown, including safety agency certifications on labels, may vary based on the date manufactured. 3. Mechanical drawings and specifications are for reference only. 4. All specifications are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at rated output load unless otherwise specified. 5. Aimtec may not have conducted destructive testing or chemical analysis on all internal components and chemicals at the time of publishing this document. CAS numbers and other limited information are considered proprietary and may not be available for release. 6. This product is not designed for use in critical life support systems, equipment used in hazardous environments, nuclear control systems or other such applications which necessitate