DATASHEET SEARCH SITE | WWW.ALLDATASHEET.COM
Document overview
- Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
- PDF pages: 7
Technical content
20 Watt | AC-DC / DC-DC Converter
www.aimtec.com Tel: +1 514 620 2722 Toll free: + 1 888 9 AIMTEC (924 6832) F 052e R8.A 1 of 7 North America only Picture coming soon FEATURES: Models Single output Model Input Voltage (VAC/Hz) Input Voltage (VDC) Output Voltage (V) Output Current max (A) Maximum capacitive Load (µF) Efficiency 230VAC (%) AME20-5SCJZ 85-264/47-63 120-370 5 3.5 12240 75 AME20-9SCJZ 85-264/47-63 120-370 9 2.1 7200 77 AME20-12SCJZ 85-264/47-63 120-370 12 1.6 5400 81 AME20-15SCJZ 85-264/47-63 120-370 15 1.3 2720 83 AME20-24SCJZ 85-264/47-63 120-370 24 0.85 1840 85 Models Dual output Model Input Voltage (VAC/Hz) Input Voltage (VDC) Output Voltage (V) Output Current max (A) Maximum capacitive Load (µF) Efficiency 230VAC (%) AME20-5DCJZ 85-264/47-63 120-370 ±5 ±2 ±8000 75 AME20-12DCJZ 85-264/47-63 120-370 ±12 ±0.83 ±960 82 AME20-15DCJZ 85-264/47-63 120-370 ±15 ±0.65 ±880 83 Models Triple output Model Input Voltage (VAC/Hz) Input Voltage (VDC) Output Voltage (V) Auxiliary Output Voltage (V) Output Current max (A) Maximum capacitive Load (µF) Efficiency 230VAC (%) AME20-505TCJZ 85-264/47-63 120-370 5 ±5 2.5/±0.5 11200/±4480 74 AME20-512TCJZ 85-264/47-63 120-370 5 ±12 2/±0.4 16000/±1600 75 AME20-515TCJZ 85-264/47-63 120-370 5 ±15 2/±0.3 13520/±370 76 AME20-524TCJZ 85-264/47-63 120-370 5 ±24 2/±0.2 11200/±370 77 Models Asymmetric Separated Dual output Model Input Voltage (VAC/Hz) Input Voltage (VDC) Output Voltage (V) Output Current max (A) Maximum capacitive Load (µF) Efficiency 230VAC (%) AME20-512DCJZ 85-264/47-63 120-370 5/12 2.5/0.6 32400/3250 75 AME20-515DCJZ 85-264/47-63 120-370 5/15 2.5/0.5 28000/1980 76 AME20-524DCJZ 85-264/47-63 120-370 5/24 2.5/0.3 28000/720 77 I/O Isolation 3000VAC Continuous Short circuit protection Operating Temp: -25 °C to +70 °C Energy Star compliant Input: 85-264VAC, 47-63Hz, or 120-370VDC Compact package Over current, Over Voltage Protection Efficiency up to 85% Click on Series name for product info on aimtec.com
www.aimtec.com Tel: +1 514 620 2722 Toll free: + 1 888 9 AIMTEC (924 6832) F 052e R8.A 2 of 7 North America only Input Specifications Parameters Conditions Typical Maximum Units Current (full load) 115 VAC 600 mA
230 VAC 340 mA
Inrush current <2ms (cold start) 115 VAC 16 A
230 VAC 30 A
Leakage current 230VAC/50Hz 0.3 mA External fuse Recommended slow blow type 3.15 A Output Specifications Parameters Conditions Typical Maximum Units Voltage accuracy ±2 % Line regulation Full load, main output ±0.5 % Full load, auxiliary output ±1.5 % Load regulation (single output) 10-100% load ±1 % Load Regulation (dual output) 10-100% Balanced load ±2 % Load Regulation (triple & asymmetric separated output) 10-100% Balanced load, main output ±3 10-100% Balanced load, auxiliary output ±5 Minimum load Single output 0 % Others 10 % Ripple & Noise * 50 150 mV p-p Hold-up time 115VAC, 20MHz bandwidth 15 ms 230VAC, 20MHz bandwidth 80 ms Voltage adjustment range ±10 % of Vout Isolation Specifications Parameters Conditions Typical Rated Units Tested I/O voltage 60 sec 3000 VAC Isolation voltage between Main and Auxiliary output 60 sec 500 VDC Isolation Resistance >1000 MΩ General Specifications Parameters Conditions Typical Maximum Units Switching frequency 100% load 65 KHz Protection class Class I Over current protection ≥110 % of Iout Over voltage protection Zener diode clamp Short circuit protection Continuous, Auto recovery Operating temperature See derating curve -25 to +70 oC Storage temperature -25 to +105 oC Maximum Case temperature 100 oC Temperature coefficient ±0.02 % / oC Cooling Free air convection Humidity Non condensing 95 % RH Case material Plastic (flammability to UL 94V-0) Weight 120 g MTBF > 300,000 hrs (MIL-HDBK -217F, t=+25oC)/Full Load NOTE: All specifications in this datasheet are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at rated output load unless otherwise specified.
www.aimtec.com Tel: +1 514 620 2722 Toll free: + 1 888 9 AIMTEC (924 6832) F 052e R8.A 3 of 7 North America only Safety Specifications Parameters Agency approvals cULus, CE (single output models only) Standards Information technology Equipment IEC/EN/UL 60950-1 EMI - Conducted and radiated emission EN55022, class B Electrostatic Discharge Immunity IEC 61000-4-2 Level 3 RF, Electromagnetic Field Immunity IEC 61000-4-3 Level 3 Electrical Fast Transient/Burst Immunity IEC 61000-4-4 Level 3 Surge Immunity IEC 61000-4-5 Level 3 RF, Conducted Disturbance Immunity IEC 61000-4-6 Level 3 Power frequency Magnetic Field Immunity IEC 61000-4-8 Level 3 Voltage dips, Short Interruptions Immunity IEC 61000-4-11 Class 2 Dimensions 70.00 (2.76) 48.00 (1.89) Bottom View 4.00 (0.16) 4.00 (0.16) 4.00 (0.16) 62.00 (2.44) 6.00 (0.24) 1.00 (0.04) 20.00 (0.79) 12.50 (0.49) 23.50 (0.93) Case Tolerance ±0.50 (±0.02) Pin Diameter 1.0 ± 0.10 (0.04 ± 0.004) Dimensions mm (inch) Ø 1.50 (Ø 0.06) DIV: 10.00 (0.40) Top View 5.75 (0.23) Pin Out Specifications Pin Single Dual Triple Asymmetric Dual
1 Ground Ground Ground Ground
2 AC Input (N) AC Input (N) AC Input (N) AC Input (N)
3 AC Input (L) AC Input (L) AC Input (L) AC Input (L)
4 Trim No pin No pin No pin
5 -V Output -V Output -V Output 1 -V Output 1
6 No pin Common +V Output 1 +V Output 1
7 No pin No pin -V Output 2 No pin
8 No pin +V Output Common -V Output 2
9 +V Output +V Output +V Output 2 +V Output 2
www.aimtec.com Tel: +1 514 620 2722 Toll free: + 1 888 9 AIMTEC (924 6832) F 052e R8.A 4 of 7 North America only Derating Typical application circuits -20 02 0 4 0 6 0 8 0 100 100 Safe Operating Area Input 100-240VAC or 120-340VDC -2 5 Free Air Convection Ambient Temperature º C 7055 Output power (%) -10 85 (100) 100 (120) 264 (350) 100 Safe Operating Area Output Power (%) Free Air Convection at 25°C Input Voltage VAC (VDC) 240 (320) AC DC AC L AC N + Vout ‐ Vout Single Output MOV S14K350 FUSE 3.15A/300V 1µF/50V NTC AC L AC N + Vout ‐ Vout + TVS Earth/GND AC DC AC L AC N + Vout ‐ Vout Dual Output MOV S14K350 FUSE 3.15A/300V 1µF/50V NTC AC L AC N + Vout ‐ Vout C2 + TVS 1 Earth/GND Com 1µF/50V C4 + Com TVS 2
www.aimtec.com Tel: +1 514 620 2722 Toll free: + 1 888 9 AIMTEC (924 6832) F 052e R8.A 5 of 7 North America only Model C2 C4 C6 TVS1 TVS2 TVS3 Single 5 Vout 330 µF - - 7V - - Single 9 Vout 220 µF - - 12V - - Single 12 & 15 Vout 220 µF - - 20V - - Single 24 Vout 220 µF - - 30V - - Dual ±5 Vout 470 µF 470 µF - 7V 7V - Dual ±12 Vout 120 µF 120 µF - 20V 20V - Dual ±15 Vout 68 µF 68 µF - 20V 20V - Triple 5/±5 Vout 330 µF 120 µF 120 µF 7V 7V 7V Triple 5/±12 Vout 330 µF 120 µF 120 µF 7V 20V 20V Triple 5/±15 Vout 330 µF 120 µF 120 µF 7V 20V 20V Triple 5/±24 Vout 330 µF 47 µF 47 µF 7V 30V 30V Dual 5/12 Vout 330 µF 220 µF - 7V 20V - Dual 5/15 Vout 330 µF 220 µF - 7V 20V - Dual 5/24 Vout 330 µF 120 µF - 7V 30V - AC DC AC L AC N + Vout 1 ‐ Vout 2 Asymmetric Dual Output MOV S14K350 FUSE 3.15A/300V 1µF/50V NTC AC L AC N Vout 2 C2 + TVS 1 Earth/GND 1µF/50V C4 + Vout 1 + Vout 2 ‐ Vout 1 TVS 2 AC DC AC L AC N + Vout 2 ‐ Vout 2 MOV S14K350 FUSE 3.15A/300V 1µF/50V NTC AC L AC N + Vout 2 ‐ Vout 2 C6 + TVS2 Earth/GND Com 1µF/50V C4 + Com 1µF/50V C2 + TVS1 ‐ ‐ Vout 1 Vout 1 Triple Output TVS3
www.aimtec.com Tel: +1 514 620 2722 Toll free: + 1 888 9 AIMTEC (924 6832) F 052e R8.A 6 of 7 North America only Trimming Output voltage can be externally trimmed by utilizing the methods as shown below Fixed Resistor Variable Potentiometer Leave open if not used. AME20‐5SCJZ Trim down % 1 2 3 4 5 6 7 8 9 10 Trim up % 1 2 3 4 5 6 7 8 9 10 AME20‐9SCJZ Trim down % 1 2 3 4 5 6 7 8 9 10 Trim up % 1 2 3 4 5 6 7 8 9 10 AME20‐12SCJZ Trim down % 1 2 3 4 5 6 7 8 9 10 Trim up % 1 2 3 4 5 6 7 8 9 10
www.aimtec.com Tel: +1 514 620 2722 Toll free: + 1 888 9 AIMTEC (924 6832) F 052e R8.A 7 of 7 North America only AME20‐15SCJZ Trim down % 1 2 3 4 5 6 7 8 9 10 Trim up % 1 2 3 4 5 6 7 8 9 10 AME20‐24SCJZ Trim down % 1 2 3 4 5 6 7 8 9 10 Trim up % 1 2 3 4 5 6 7 8 9 10 NOTE: 1. Datasheets are updated as needed and as such, specifications are subject to change without notice. Once printed or downloaded, datasheets are no longer controlled by Aimtec; refer to www.aimtec.com for the most current product specifications. 2. Product labels shown, including safety agency certifications on labels, may vary based on the date manufactured. 3. Mechanical drawings and specifications are for reference only. 4. All specifications are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at rated output load unless otherwise specified. 5. Aimtec may not have conducted destructive testing or chemical analysis on all internal components and chemicals at the time of publishing this document. CAS numbers and other limited information are considered proprietary and may not be available for release. 6. This product is not designed for use in critical life support systems, equipment used in hazardous environments, nuclear control systems or other such applications which necessitate