10 Watt | AC-DC / DC-DC Converter
www.aimtec.com Tel: +1 514 620 2722 Toll free: + 1 888 9 AIMTEC (924 6832) F 052e R8. D 1 of 7 North America only FEATURES: Models Single output Model Input Voltage (VAC/Hz) Input Voltage (VDC) Output Voltage (V) Output Current max (A) Maximum capacitive Load (µF) Efficiency 230VAC (%) AME10-3.3SCJZ 85-264/47-63 120-370 3.3 2 26400 70 AME10-5SCJZ 85-264/47-63 120-370 5 2 9440 76 AME10-9SCJZ 85-264/47-63 120-370 9 1.1 3600 78 AME10-12SCJZ 85-264/47-63 120-370 12 0.9 2400 80 AME10-15SCJZ 85-264/47-63 120-370 15 0.7 1170 81 AME10-24SCJZ 85-264/47-63 120-370 24 0.45 370 82 Models Dual output Model Input Voltage (VAC/Hz) Input Voltage (VDC) Output Voltage (V) Output Current max (A) Maximum capacitive Load (µF) Efficiency 230VAC (%) AME10-5DCJZ 85-264/47-63 120-370 ±5 ±1 ±8800 76 AME10-12DCJZ 85-264/47-63 120-370 ±12 ±0.45 ±1970 80 AME10-15DCJZ 85-264/47-63 120-370 ±15 ±0.35 ±1970 81 AME10-24DCJZ 85-264/47-63 120-370 ±24 ±0.2 ±660 84 Models Triple output Model Input Voltage (VAC/Hz) Input Voltage (VDC) Output Voltage (V) Auxiliary Output Voltage (V) Output Current max (A) Maximum capacitive Load (µF) Efficiency 230VAC (%) AME10-512TCJZ 85-264/47-63 120-370 5 ±12 1/±0.2 3200/±260 75 AME10-515TCJZ 85-264/47-63 120-370 5 ±15 0.9/±0.2 2160/±80 75 Models Asymmetric Separated Dual output Model Input Voltage (VAC/Hz) Input Voltage (VDC) Output Voltage (V) Output Current max (A) Maximum capacitive Load (µF) Efficiency 230VAC (%) AME10-505DCJZ 85-264/47-63 120-370 5/5 1.8/0.2 8000/540 75 AME10-512DCJZ 85-264/47-63 120-370 5/12 1.5/0.2 4400/260 79 AME10-515DCJZ 85-264/47-63 120-370 5/15 1.4/0.2 4400/170 79 AME10-524DCJZ 85-264/47-63 120-370 5/24 1/0.2 4000/170 81 AME10-1224DCJZ 85-264/47-63 120-370 12/24 0.42/0.2 1100/170 80 Note: Add suffix “-ST” for optional screw terminal bottom plate or “-STD” for optional DIN Rail screw terminal bottom plate.
- I/O Isolation 3000VAC • Continuous Short circuit protection
- Operating Temp: -25 °C to +70 °C • Energy Star compliant
- Input: 85-264VAC, 47-63Hz, or 120-370VDC • Compact package
- Over current, Over Voltage Protection • Efficiency up to 84% Click on Series name for product info on aimtec.com
www.aimtec.com Tel: +1 514 620 2722 Toll free: + 1 888 9 AIMTEC (924 6832) F 052e R8. D 2 of 7 North America only Input Specifications Parameters Conditions Typical Maximum Units Current (full load) 115 VAC 260 mA
230 VAC 160 mA
Inrush current <2ms (cold start) 115 VAC 10 A
230 VAC 20 A
Leakage current 230VAC/50Hz 0.3 mA External fuse Recommended slow blow type 2 A Output Specifications Parameters Conditions Typical Maximum Units Voltage accuracy ±2 % Line regulation Full load, main output ±0.5 % Full load, auxiliary output ±1.5 % Load regulation (single output) 10-100% load ±1 % Load Regulation (dual output) 10-100% Balanced load ±2 % Load Regulation (triple & asymmetric separated output) 10-100% Balanced load, main output ±3 10-100% Balanced load, auxiliary output ±5 Minimum load Single output 0 % Others 10 % Ripple & Noise * 50 150 mV p-p Hold-up time 115VAC, 20MHz bandwidth 15 ms 230VAC, 20MHz bandwidth 80 ms Isolation Specifications Parameters Conditions Typical Rated Units Tested I/O voltage 60 sec 3000 VAC Isolation voltage between Main and Auxiliary output 60 sec 500 VDC Isolation Resistance >1000 MΩ General Specifications Parameters Conditions Typical Maximum Units Switching frequency 100% load 65 KHz Protection class Class I Over current protection ≥110 % of Iout Over voltage protection Zener diode clamp Short circuit protection Continuous, Auto recovery Operating temperature See derating curve -25 to +70 oC Storage temperature -25 to +105 oC Maximum Case temperature 100 oC Temperature coefficient ±0.02 % / oC Cooling Free air convection Humidity Non condensing 95 % RH Case material Plastic (flammability to UL 94V-0) Weight PCB mountable model: With optional -ST mounting plate: With optional -STD mounting plate: 130 170 g Dimensions (L x W x H) PCB mountable model: With optional -ST mounting plate: With optional -STD mounting plate: MTBF > 300,000 hrs (MIL-HDBK -217F, t=+25oC)/Full Load NOTE: All specifications in this datasheet are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at rated output load unless otherwise specified.
www.aimtec.com Tel: +1 514 620 2722 Toll free: + 1 888 9 AIMTEC (924 6832) F 052e R8. D 3 of 7 North America only Safety Specifications Parameters Agency approvals cULus (except triple output models and AME10-1224DCJZ), CE Standards Information technology Equipment IEC/EN/UL 60950-1 EMI - Conducted and radiated emission EN55022, class B Electrostatic Discharge Immunity IEC 61000-4-2 Level 3 RF, Electromagnetic Field Immunity IEC 61000-4-3 Level 3 Electrical Fast Transient/Burst Immunity IEC 61000-4-4 Level 3 Surge Immunity IEC 61000-4-5 Level 3 RF, Conducted Disturbance Immunity IEC 61000-4-6 Level 3 Power frequency Magnetic Field Immunity IEC 61000-4-8 Level 3 Voltage dips, Short Interruptions Immunity IEC 61000-4-11 Class 2 Dimensions 55.00 (2.17) 45.00 (1.77) Bottom View 5.00 (0.20) 4.00 (0.16) 4.00 (0.16) 47.00 (1.85) 6.00 (0.24) 1.00 (0.04) 17.50 (0.69) 12.50 (0.49) 21.00 (0.83) Case Tolerance ±0.50 (±0.02) Pin Diameter 1.0 ± 0.10 (0.04 ± 0.004) Dimensions mm (inch) Ø 1.50 (Ø 0.06) DIV: 10.00 (0.40) Top View 2 6 5.00 (0.20) Pin Out Specifications Pin Single Dual Triple Asymmetric Dual
1 Ground Ground Ground Ground
2 AC Input (N) AC Input (N) AC Input (N) AC Input (N)
3 AC Input (L) AC Input (L) AC Input (L) AC Input (L)
4 -V Output -V Output -V Output 1 -V Output 1
5 No pin No pin +V Output 1 +V Output 1
6 No pin Common -V Output 2 No pin
7 No pin No pin Common -V Output 2
8 +V Output +V Output +V Output 2 +V Output 2
www.aimtec.com Tel: +1 514 620 2722 Toll free: + 1 888 9 AIMTEC (924 6832) F 052e R8. D 4 of 7 North America only With optional -ST bottom plate 96.10 (3.78) 86.10 (3.39) 54.00 (2.13) Side view 29.50 (1.16) 20.60 (0.81) 8.50 (0.34) Top view MST Ø 3.50 (0.14) 46.00 (1.81) Dimensions: mm (inch) Case Tolerance:± 0.50 (0.02) Wire gauge: 24-12AWG
www.aimtec.com Tel: +1 514 620 2722 Toll free: + 1 888 9 AIMTEC (924 6832) F 052e R8. D 5 of 7 North America only With optional -STD bottom plate 96.10 (3.78) 86.10 (3.39) 54.00 (2.13) 34.10 (1.34) 25.20 (0.99) 8.50 (0.34) MST 46.00 (1.81) Dimensions: mm (inch) Case Tolerance:± 0.50 (0.02) Wire gauge: 24-12AWG Top view Side view Derating -20 0 20 40 60 80 100 100 Safe Operating Area Input 100-240VAC or 120-340VDC - 25 Free Air Convection Ambient Temperature º C 7055 Output power (%) -10 (100) 100 (120) 264 (350) 100 Safe Operating Area Output Power (%) Free Air Convection at 25°C Input Voltage VAC (VDC) 240 (320)
www.aimtec.com Tel: +1 514 620 2722 Toll free: + 1 888 9 AIMTEC (924 6832) F 052e R8. D 6 of 7 North America only Typical application circuits AC DC AC L AC N + Vout - Vout Single Output MOV S14K350 FUSE 2A/300V 1µF/50V NTC AC L AC N + Vout - Vout + TVS Earth/GND AC DC AC L AC N + Vout - Vout Dual Output MOV S14K350 FUSE 2A/300V 1µF/50V NTC AC L AC N + Vout - Vout C2 + TVS 1 Earth/GND Com 1µF/50V C4 + Com TVS 2 AC DC AC L AC N + Vout 1 - Vout 2 Asymmetric Dual Output MOV S14K350 FUSE 2A/300V 1µF/50V NTC AC L AC N Vout 2 C2 + TVS 1 Earth/GND 1µF/50V C4 + Vout 1 + Vout 2 - Vout 1 TVS 2 AC DC AC L AC N + Vout 2 - Vout 2 MOV S14K350 FUSE 2A/300V 1µF/50V NTC AC L AC N + Vout 2 - Vout 2 C6 + TVS2 Earth/GND Com 1µF/50V C4 + Com 1µF/50V C2 + TVS1 - - Vout 1 Vout 1 Triple Output TVS3
www.aimtec.com Tel: +1 514 620 2722 Toll free: + 1 888 9 AIMTEC (924 6832) F 052e R8. D 7 of 7 North America only NOTE: 1. Datasheets are updated as needed and as such, specifications are subject to change without notice. Once printed or downloaded, datasheets are no longer controlled by Aimtec; refer to www.aimtec.com for the most current product specificati ons. 2. Product labels shown, including safety agency certifications on labels, may vary based on the date manufactured. 3. Mechanical drawings and specifications are for reference only. 4. All specifications are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at rated output load unless otherwise specified. 5. Aimtec may not have conducted destructive testing or chemical analysis on all internal components and chemicals at the time of publishing this document. CAS number s and other limited information are considered proprietary and may not be available for release. 6. This product is not designed for use in critical life support systems, equipment used in hazardous environments, nuclear control s ystems or other such applications which necessitate Model C2 C4 C6 TVS1 TVS2 TVS3 Single 3.3 Vout 470 µF - - 7V - - Single 5 Vout 330 µF - - 7V - - Single 9 Vout 120 µF - - 12V - - Single 12 & 15 Vout 120 µF - - 20V - - Single 24 Vout 68 µF - - 30V - - Dual ±5 Vout 220 µF 220 µF - 7V 7V - Dual ±12 Vout 120 µF 120 µF - 20V 20V - Dual ±15 Vout 47 µF 47 µF - 20V 20V - Dual ±24 Vout 33 µF 33 µF - 30V 30V - Triple 5/±12 Vout 220 µF 68 µF 68 µF 7V 20V 20V Triple 5/±15 Vout 220 µF 47 µF 47 µF 7V 20V 20V Dual 5/5 Vout 220 µF 68 µF - 7V 7V - Dual 5/12 Vout 220 µF 68 µF - 7V 20V - Dual 5/15 Vout 220 µF 47 µF - 7V 20V - Dual 5/24 Vout 220 µF 47 µF - 7V 30V -