1Watt | AC-DC / DC-DC Converter www.aimtec.com Tel: +1 514 620 2722 Toll free: + 1 888 9 AIMTEC (924 6832) F 052e R8 1 of 3 North America only FEATURES: Picture coming soon Models Single output Model Input Voltage (VAC/Hz) Input Voltage (VDC) Temperature range (ºC) Output Voltage (V) Output Current max (mA) Maximum capacitive Load (µF) Efficiency (%) 230 VAC AME1-3.3SJZ 85-305/47-63 120-430 -25 to +70 3.3 300 4000 63 AME1-5SJZ 85-305/47-63 120-430 -25 to +70 5 200 4000 68 AME1-9SJZ 85-305/47-63 120-430 -25 to +70 9 111 2200 72 AME1-12SJZ 85-305/47-63 120-430 -25 to +70 12 83 2200 73 AME1-15SJZ 85-305/47-63 120-430 -25 to +70 15 67 1000 74 AME1-24SJZ 85-305/47-63 120-430 -25 to +70 24 42 680 75 Input Specifications Parameters Conditions Typical Maximum Units Current (full load) 115 VAC 30 mA
230 VAC 17 mA
Inrush current <2ms (cold start) 115 VAC 5 A
230 VAC 11 A
Leakage current 0.15 mA External fuse Recommended slow blow type 1 A Output Specifications Parameters Conditions Typical Maximum Units Voltage accuracy Full load, nominal input ±6 % Line regulation LL-HL, Full Load ±2 % Load regulation 10% - 100% load, nominal input ±5 % Minimum load 10 % Ripple & Noise* 3.3/5 VDC With 560µF E/C 100 200 mV p-p *Ripple &Noise measured at 20MHz bandwidth with 1µF C/C and 10µF E/C and 115/230VAC with Full Load. Isolation Specifications Parameters Conditions Typical Rated Units Tested I/O voltage 60 sec 3000 VAC Isolation Resistance >1000 MΩ General Specifications Parameters Conditions Typical Maximum Units Switching frequency 100 KHz Over Current protection Auto recovery ≥110% Short circuit protection Auto recovery Operating temperature With derating above 55°C -25 to +70 °C Storage temperature -40 to +85 °C Maximum Case temperature 100 °C Humidity Non condensing 20 ~ 90 % RH Case material Plastic resin (flammability to UL 94V-0) Weight 20 g Cooling Free air convection MTBF > 300,000 hrs (MIL-HDBK -217F, t=+25oC)/Full Load NOTE: All specifications in this datasheet are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at rated output load unless otherwise specified.
- I/O Isolation 3000VAC • Class II Power supply
- Operating Temp: -25°C to +70°C
- Input: 85-305VAC, 47-63Hz, or 120-430 VDC
- Over current, Short Circuit Protection
- Energy Star compliant
- Ultra-small package Click on Series name for product info on aimtec.com
1Watt | AC-DC / DC-DC Converter www.aimtec.com Tel: +1 514 620 2722 Toll free: + 1 888 9 AIMTEC (924 6832) F 052e R8 2 of 3 North America only Safety Specifications Parameters Approvals cULus, CE pending Standards Information technology Equipment Meets IEC/EN/UL 60950-1:2006+A11:2009 EMI - Conducted and radiated emission EN55022, class B, with application circuit Electrostatic Discharge Immunity IEC 61000-4-2, Contact:±4KV/Air:±8KV, Criteria B RF, Electromagnetic Field Immunity IEC 61000-4-3, 10V/m, Criteria A Electrical Fast Transient/Burst Immunity IEC 61000-4-4, ±2KV, Criteria B, with EMC recommended circuit Surge Immunity(1KV) IEC 61000-4-5, ±1KV/±2KV, Criteria B, with EMC recommended circuit RF, Conducted Disturbance Immunity IEC 61000-4-6, 10Vrms, Criteria A Power frequency Magnetic Field Immunity IEC 61000-4-8, 10A/m, Criteria A Voltage dips, Short Interruptions Immunity IEC 61000-4-11, 0-70%, Criteria B Pin Out Specifications Dimensions Derating Pin Single
1 AC Input (N)
2 AC Input (L)
15.24 (0.60) 28.00 (1.10) 18.00 (0.71) 6.00 (0.24) Dimensions mm (inch) Case Tolerance ±0.50 (±0.02) Pin Diameter ±0.10(±0.004) Pin Pitch Tolerance ±0.50 (±0.02) 0.60 (0.02) ew easuring point 16.85 (0.66) Top Vi Temperature m 3 11.00 (0.43) DIV: 5.00 (0.20) Ø 10.0 ( Ø 0.40) Ø 0.60 ( Ø 0.02) 1 3 Top View 7.60 22.00 (0.87) (0.29) Side View 33.70 (1.33) -20 0 20 40 60 80 100 100 Safe Operating Area - 25 Free Air Convection Ambient Temperature º C 7055
1Watt | AC-DC / DC-DC Converter www.aimtec.com Tel: +1 514 620 2722 Toll free: + 1 888 9 AIMTEC (924 6832) F 052e R8 3 of 3 North America only Application circuit *GND connection not allowed EMC recommended circuit NOTE: 1. Datasheets are updated as needed and as such, specifications are subject to change without notice. Once printed or downloaded, datasheets are no longer controlled by Aimtec; refer to www.aimtec.com for the most current product specifications. 2. Product labels shown, including safety agency certifications on labels, may vary based on the date manufactured. 3. Mechanical drawings and specifications are for reference only. 4. All specifications are measured at an ambient temperature of 25°C, humidity< 75%, nominal input voltage and at rated output load unless otherwise specified. 5. Aimtec may not have conducted destructive testing or chemical analysis on all internal components and chemicals at the time of publishing this document. CAS numbers and ot her limited information are considered proprietary and may not be available for release. 6. This product is not designed for use in critical life support systems, equipment used in hazardous environments, nuclear control s ystems or other such applications which necessitate Model C2 TVS 3.3 & 5 Vout 220 µF / 35V 7V
9 Vout 120 µF / 35V 12V
12 & 15 Vout 120 µF / 35V 20V
24 Vout 68 µF / 35V 30V
+ Vout - Vout Single Output MOV S14K350 FUSE 1A/300V 1µF/50V NTC AC L AC N + TVSCX 0.1µF/ 305VAC AC DC AC L AC N + Vout - Vout Single Output MOV S14K350 FUSE 1A/300V 1µF/50V AC L AC N + TVS LCM 10mH CX 0.1µF/ 305VAC GND CY1 2.2nF/ 400VAC CY2 2.2nF/ 400VAC NTC