AMD-12V030WXYA DELTA | Alldatasheet

Document overview

  • Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
  • PDF pages: 5

Technical content

Switch Mode Power Supply Medical Adapter AMD-12V030WxyA 1/5 Rev: 00.2, 3/21/2011 Summary The AMD-12V030WxyA is the Medical Adapter from one of the world’s largest power supply manufacturers -Delta. The product offers a regulated output voltage of 12V, along with wide temperature range from 0°C to +40°C and a minimum holdup time of 15ms. The state-of-the-art design is made to withstand medical equipment requirements. The rugged, ultra- compact plastic case with shock and vibration resistances. The 30 watts Medical power supply provides overvoltage, overload and over temperature protection. Due to the wide input voltage range from 90 to 264Vac (Nominal input: 100Vac to 240 Vac), the Delta’s medical power supply is worldwide usable. The Input Socket & output connector are made for easy installation. Features:  30Watts Output Power.  100-240Vac Universal Input.  AC Receptacle with C8 & C14 option (IEC320AC receptacle)  Efficiency > 83.5%  No load power consumption < 0.3W  Energy star Compliant (Level V)  Low leakage current  Brownout & Brownout Recovery  Medical safety standard compliant UL60601- 11/EN60601-1/CSA60601-1  MTBF: > 600,000 Hrs. MODEL: AMD-12V030WxyA

Switch Mode Power Supply Medical Adapter AMD-12V030WxyA 2/5 Rev: 00.2, 3/21/2011 Technical Data 30W Medical Adapter Input Data (1) Nominal input voltage (wide-range input) 100V-240VAC Input Voltage range 90V-264VAC Frequency 47-63 Hz Max Input Current 0.65A max @ 115VAC, 0.40A max @ 230VAC Inrush current limitation. I t (+25 °C) typ. 25A @ 115VAC & 50A @ 230VAC Efficiency (at 115VAC and nominal values) > 83.5% No load power consumption < 0.3W Mains buffering at nominal load (typ.) 15 msec min @ 115VAC Turn-on time after applying the mains voltage 3Sec Transient surge voltage protection VARISTOR Input fuse, internal (device protection) T 3.15 AH / 250VAC Discharge current to PE < 0.25mA Altitude 3,000 m. Output Data (2) Nominal output voltage UN / tolerance 12V ± 2% Setting range of the output voltage 11.7V-12.3V Nominal output current IN convection cooling 2.5A Max. power dissipation idling/nominal load approx. 30W Ripple/ Noise (20 MHz) <120mVpp @ +25 °C Line Regulation + 0.5% Load Regulation : Exclude output cord : + 1% Include output cord + 5% Protection : Over Current (Auto Recovery) Over Voltage (Latch) Over Temperature (Latch) Certification/Standards Electrical safety (of information technology equipment) UR/cUR As per STD UL60601-1/CSA60601-1, CB scheme to EN/IEC60601-1, NEMKO EN60601-1, CE Mark LVD and EMC RoHS Compliant Yes

Switch Mode Power Supply Medical Adapter AMD-12V030WxyA 3/5 Rev: 00.2, 3/21/2011 General Data MTBF > 600,000 Hrs Type of housing Plastic Enclosed , 94V-1 Polycarbonate, Black Dimensions (W / H / D) 62 * 30 * 110 mm Weight 220 g. (reference) Climatic Data Ambient temperature (Operating) Ambient temperature (Storage) 0 °C to 40 °C -35 °C to + 85 °C Humidity 5% to 95% non-condensing In conformance with EMC guideline 89/336/EEC and low voltage directive 73/23/EEC EMC (electromagnetic compatibility) FCC (Title 47 Part 15 Class B), EN55022 (CISPR 22 Class B) Immunity to interference according to EN 61000-6-1  EN 61000-4-2 Housing Discharge of static electricity (ESD) Contact discharge: Air Discharge : Level 4 8 kV 15 kV  EN 61000-4-3 Housing Electromagnetic HF field Frequency/Field intensity: Level 3 80Hz – 1GHz / 10V/M, with 1kHz tone/80% modulation  EN 61000-4-4 Input Fast transients (Burst): L,N,PE : Signal: Level 3 2kV  EN 61000-4-5 Input : Surge voltage capacities (Surge): Common Mode : Differential Mode : Level 3 2kV 1kV  EN 61000-4-6 I/O:  Conducted disturbance Frequency / U o: Level 3 0.15MHz - 80MHz / 10Vrms.  EN 61000-4-11 Voltage dips Self recoverable, No damage Noise emission according to EN 61000-6-3  Emitted radio interface  Radio interference voltage EN55011 (EN55022) CLASS B EN55011 (EN55022) CLASS B EN55011 corresponds to CISPR11 / EN55022 corresponds to CISPR22 / EM 61000 corresponds to IEC 1000 1) Criterion A: Normal operating behavior within the defined limits. 2) Criterion B: Temporary impairment to operational behavior that is corrected by the device itself. 3) Symmetrical: Conductor to conductor. 4) Asymmetrical: Conductor to ground. 5) Class B: Area of application industry and residential

Switch Mode Power Supply Medical Adapter AMD-12V030WxyA 4/5 Rev: 00.2, 3/21/2011 Numbering for Medical Adapter For example: AMD-12V030WxyA XX X XXXX XXXX X XX AM Medical Adapter XX X XXXX XXXX X XX D Desktop XX X XXXX XXXX X XX XX X XXXX XXXX X XX 030W 30 Watt 060W 60 Watt 080W 80 Watt XX X XXXX XXXX X XX X……………...Input Configuration 2 2 PIN AC 3 3 PIN AC XX X XXXX XXXX X X X A Inner diameter 2,5 mm B Inner diameter 2,1 mm *** Outer Diameter 5,5 mm. XX X XXXX XXXX XX X (Eg, Customer, material,Etc.) AD e l t a Standard -product 12V 12 Voltage

Switch Mode Power Supply Medical Adapter AMD-12V030WxyA 5/5 Rev: 00.2, 3/21/2011 Mechanical drawing