9 Watt | DC-DC Converter
www.aimtec.com Tel: +1 514 620 2722 Toll free: + 1 888 9 AIMTEC (924 6832) F 051e R1 1 of 5 North America only Picture coming soon FEATURES: Models Single Output Model Input Voltage (V) Output Voltage (V) Output Current Max (mA) Isolation (VDC) Input Current Full | No Load (mA) Capacitor Load (μF) Efficiency (%) AM9G-1203SZ 9-18 3.3 2000 1600 679 15 2600 81 AM9G-1205SZ 9-18 5 1600 1600 784 15 1300 85 AM9G-1209SZ 9-18 9 1000 1600 862 15 800 87 AM9G-1212SZ 9-18 12 750 1600 852 15 560 88 AM9G-1215SZ 9-18 15 600 1600 843 15 470 89 AM9G-1224SZ 9-18 24 375 1600 843 15 200 89 AM9G-2403SZ 18-36 3.3 2000 1600 344 15 2600 80 AM9G-2405SZ 18-36 5 1600 1600 392 15 1300 85 AM9G-2409SZ 18-36 9 1000 1600 426 15 800 88 AM9G-2412SZ 18-36 12 750 1600 421 15 560 89 AM9G-2415SZ 18-36 15 600 1600 417 15 470 90 AM9G-2424SZ 18-36 24 375 1600 417 15 200 90 AM9G-4803SZ 36-75 3.3 2000 1600 168 10 2600 82 AM9G-4805SZ 36-75 5 1600 1600 196 10 1300 85 AM9G-4809SZ 36-75 9 1000 1600 213 10 800 88 AM9G-4812SZ 36-75 12 750 1600 211 10 560 89 AM9G-4815SZ 36-75 15 600 1600 211 10 470 89 AM9G-4824SZ 36-75 24 375 1600 211 10 200 89 Models Dual output Model Input Voltage (V) Output Voltage (V) Output Current Max (mA) Isolation (VDC) Input Current Full | No Load (mA) Capacitor Load (μF) Efficiency (%) AM9G-1205DZ 9-18 ±5 ±800 1600 784 15 ±800 85 AM9G-1212DZ 9-18 ±12 ±375 1600 852 15 ±390 88 AM9G-1215DZ 9-18 ±15 ±300 1600 843 15 ±200 89 AM9G-2405DZ 18-36 ±5 ±800 1600 388 15 ±800 86 AM9G-2412DZ 18-36 ±12 ±375 1600 421 15 ±390 89 AM9G-2415DZ 18-36 ±15 ±300 1600 431 15 ±200 87 AM9G-4805DZ 36-75 ±5 ±800 1600 194 10 ±800 86 AM9G-4812DZ 36-75 ±12 ±375 1600 216 10 ±390 87 AM9G-4815DZ 36-75 ±15 ±300 1600 216 10 ±200 87 NOTE: All specifications in this datasheet are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at rated output load unless otherwise specified Input Specifications Parameters Nominal Typical Maximum Units Voltage range 9-18 18-36 36-75 VDC Filter Capacitor Transient recovery time 100% - 25% load, 25% load step change 250 µs Transient Response deviation 100% - 25% load, 25% load step change 100% - 25% load, 25% load step change, 3.3 & 5 V output ±5 % Startup time 50 ms
- SIP8 Metal Case Package • Operating Temperature -40°C to +85°C
- High Efficiency up to 90% • Continuous Short Circuit Protection
- On / Off Control
- Input Under Voltage Lockout
- Input / Output Isolation 1600VDC
- Over Voltage and Over Current Protection Click on Series name for product info on aimtec.com
www.aimtec.com Tel: +1 514 620 2722 Toll free: + 1 888 9 AIMTEC (924 6832) F 051e R1 2 of 5 North America only Absolute Maximum Rating
12 Vin
24 Vin
48 Vin
On / Off Control ON – high impedance or open; OFF – 2-4mA input current through 1KΩ (standby 2.5mA max) Under Voltage lockout 8.9 / 7 VDC Isolation Specifications Parameters Conditions Typical Rated Units Tested I/O voltage 60 sec 1600 VDC Case / Input or Output 60 sec 1000 VDC Resistance > 1000 MOhm Capacitance 50 pF Output Specifications Parameters Conditions Typical Maximum Units Voltage accuracy ±1 % Cross Regulation (Dual) 1st output 25% to 100%, 2nd output 100% ±5 % Short Circuit protection Continuous Short Circuit restart Auto recovery Line voltage regulation LL~HL ±0.2 % Load voltage regulation (Single) 0-100% load, 3.3 Vin 0-100% load, others ±1 ±0.5 % Load voltage regulation (Dual) 0-100% balanced load ±1 % Over Voltage protection 130 % Over Current protection 150 % Temperature coefficient ±0.02 %/oC Ripple & Noise* At 20MHz Bandwidth 75 mV p-p *Measured with 1µF CC and 10µF EC. General Specifications Parameters Conditions Typical Maximum Units Switching frequency 100% load, 12 & 24Vin models 100% load, 48Vin models 400 500 KHz Operating temperature Refer Derating Curve -40 to +85 oC Storage temperature -55 to +125 oC Max Case temperature +100 oC Cooling Free air convection (30 – 65 LFM) Humidity 5 - 95 % Case material Copper Potting material Epoxy (UL94V-0 rated) Pin Material C5191R-H Solder coated Weight 7.3 g MTBF >900,000 hrs (MIL-HDBK -217F, Ground Benign, t=+25oC) Maximum soldering temperature 1.5mm from case for 10 sec max 260 oC Safety Specifications Parameters Standards EN55032 Class A, EN55024 (external class A circuit required) IEC61000-4-2, Perf. Criteria B IEC61000-4-3, Perf. Criteria A IEC61000-4-4, Perf. Criteria A (external EFT/Surge circuit required) IEC61000-4-5, Perf. Criteria A (external EFT/Surge circuit required) IEC61000-4-6, Perf. Criteria A
www.aimtec.com Tel: +1 514 620 2722 Toll free: + 1 888 9 AIMTEC (924 6832) F 051e R1 3 of 5 North America only IEC61000-4-8, Perf. Criteria A NOTE: designed to meet IEC 60950-1:2001 Pin Out Specifications Dimensions Input Reflected Ripple Test Circuit Derating Control ON/OFF pin connection example: NOTE: The voltage could be applied trough a limiting resistor. The converter is turned on when the external switching circuit is open. Pin 1600 VDC Single Dual 1 - V Input - V Input 2 + V Input + V Input
3 On/Off Control On/Off Control
8 N.C. - V Output PRINTED FACE 21.85 (0.86) 10.60 (0.42) 0.60 (0.02) 2.54 (0.10) 17.78 (0.70) 4.10 (0.16) 9.60 (0.38) 11.20 (0.44) 9.60 (0.38) 3.42 (0.14) 0.25 (0.01) 0.50 (0.02) 1.00 (0.04) 7.62 (0.30) 3.50 (0.14) 2.50 (0.10) Standoff 1 2 3 6 7 8 NOTE: All dimensions are in mm (inches) Pin pitch and length tolerance: ±0.35 (±0.014) Case tolerance: ±0.5 (±0.02) Standoff tolerance: ±0.1 (±0.004) Aimtec DC-DC Converter Lin 12µH Cin 47µF Test Point RL (Full Load) Vo+ Vo- * Tested at full load, and nominal input - 40 - 20 0 20 40 60 80 100 100 Safe Operating Area Output Power (%) Ambient Temperature º C Free Air Convection 60º C Others 50º C 3.3Vin Converter Pin 3 +Vin -Vin 2 – 4 mA Pin 1
www.aimtec.com Tel: +1 514 620 2722 Toll free: + 1 888 9 AIMTEC (924 6832) F 051e R1 4 of 5 North America only EFT/Surge Application circuit Vin C1 D1 12VDC 300µF/100V TVS, 3kW, 26V 24VDC TVS, 3kW, 75V 48VDC TVS, 3kW, 120V Class A EMI, external filter Single output models Vin C1 C2 C3, C4 C5 L 12VDC 10µF/35V - 1nF/3KV - 3.3µH 24VDC 4.7µF/100V 4.7µF/100V 1nF/3KV - 10µH 48VDC 220pF/3KV DC/DC Converter +Vin -Vin +Vout -Vout Load C1 D1 L DC/DC Converter +V input -V input +V output Load -V output
www.aimtec.com Tel: +1 514 620 2722 Toll free: + 1 888 9 AIMTEC (924 6832) F 051e R1 5 of 5 North America only Dual output models NOTE: 1. Datasheets are updated as needed and as such, specifications are subject to change without notice. Once printed or downloaded, datasheets are no longer controlled by Aimtec; refer to www.aimtec.com for the most current product specifications. 2. Product labels shown, including safety agency certifications on labels, may vary based on the date manufactured. 3. Mechanical drawings and specifications are for reference only. 4. All specifications are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at rated output load unless otherwise specified. 5. Aimtec may not have conducted destructive testing or chemical analysis on all internal components and chemicals at the time of publishing this document. CAS numbers and other limited information are considered proprietary and may not be available for release. 6. This product is not designed for use in critical life support systems, equipment used in h azardous environments, nuclear control systems or other such applications which necessitate Vin C1 C2 C3, C4 C5 L 12VDC 10µF/35V - 1nF/3KV - 3.3µH 24VDC 4.7µF/100V 4.7µF/100V 1nF/3KV - 10µH 48VDC 220pF/3KV DC/DC Converter +V input -V input +V output Load -V output C2C1 L Common Load