8Watt | DC-DC Converter www.aimtec.com Tel: +1 514 620 2722 Toll free: + 1 888 9 AIMTEC (924 6832) F 051e R12.F 1 of 4 North America only FEATURES: Wide 4:1 input range Operating temperature -40 oC to + 85oC Remote On/Off control Input / Output Isolation 1600 & 3000VDC High efficiency up to 87% Continuous short circuit protection Over Voltage/Overload Protection Under voltage lockout for 3000VDC models Models Single output Model Input Voltage (V) Output Voltage (V) Output Current max (mA) Isolation (VDC) Max Capacitive Load(uF) Efficiency (%) AM8TW-2403SZ 9-36 3.3 2000 1600 1330 83 AM8TW-2405SZ 9-36 5 1500 1600 1330 86 AM8TW-2412SZ 9-36 12 665 1600 288 87 AM8TW-2415SZ 9-36 15 535 1600 200 87 AM8TW-4803SZ 18-75 3.3 2000 1600 1330 82 AM8TW-4805SZ 18-75 5 1500 1600 1330 86 AM8TW-4812SZ 18-75 12 665 1600 288 87 AM8TW-4815SZ 18-75 15 535 1600 200 87 AM8TW-2403SH30Z 13-70 3.3 2000 3000 1330 83 AM8TW-2405SH30Z 13-70 5 1500 3000 1330 86 AM8TW-2412SH30Z 13-70 12 665 3000 330 85 AM8TW-2415SH30Z 13-70 15 535 3000 220 86 AM8TW-11003SH30Z 42-176 3.3 2000 3000 1330 81 AM8TW-11005SH30Z 42-176 5 1500 3000 1330 84 AM8TW-11012SH30Z 42-176 12 665 3000 330 84 AM8TW-11015SH30Z 42-176 15 535 3000 220 83 Models Dual output Model Input Voltage (V) Output Voltage (V) Output Current max (mA) Isolation (VDC) Max Capacitive Load(uF) Efficiency (%) AM8TW-2405DZ 9-36 ±5 ±800 1600 ±900 84 AM8TW-2412DZ 9-36 ±12 ±335 1600 ±133 86 AM8TW-2415DZ 9-36 ±15 ±265 1600 ±90 87 AM8TW-4805DZ 18-75 ±5 ±800 1600 ±900 84 AM8TW-4812DZ 18-75 ±12 ±335 1600 ±133 87 AM8TW-4815DZ 18-75 ±15 ±265 1600 ±90 87 AM8TW-2405DH30Z 13-70 ±5 ±800 3000 ±900 83 AM8TW-2412DH30Z 13-70 ±12 ±335 3000 ±220 85 AM8TW-2415DH30Z 13-70 ±15 ±265 3000 ±100 86 AM8TW-11005DH30Z 42-176 ±5 ±800 3000 ±900 80 AM8TW-11012DH30Z 42-176 ±12 ±335 3000 ±220 82 AM8TW-11015DH30Z 42-176 ±15 ±265 3000 ±100 83 NOTE: All specifications in this datasheet are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at rated output load unless otherwise specified. Click on Series name for product info on aimtec.com
8Watt | DC-DC Converter www.aimtec.com Tel: +1 514 620 2722 Toll free: + 1 888 9 AIMTEC (924 6832) F 051e R12.F 2 of 4 North America only Input Specifications Parameters Nominal Typical Maximum Units Voltage range 24 for 1600VDC models 9-36 VDC 48 for 1600VDC models 18-75 24V or 48V for 3000VDC models 13-70 110V 42-176 Filter (Pi) Network Startup time For 1600VDC Isolation models 20 ms For 3000VDC Isolation models 30 Absolute Maximum Rating 24 for 1600VDC models -0.7-50 VDC 48 for 1600VDC models -0.7-100 24V or 48V for 3000VDC models 100 110V 185 Peak Input Voltage time 100 ms On/Off control ON – 3.0 ~ 12VDC (or open) OFF -0~1.2VDC (or short between pin 1 and 2/3), Idle current 5mA, typ. No Load Input Current 15 mA Input reflected current With 12uH inductance 20 mAp-p Under voltage Lockout (On/Off) 24V or 48V for 3000VDC models On – 12V/ Off – 11.7 VDC 110V On – 39.5V/ Off – 38 Transient recovery time 25% load step change, 1A/us 250 uS Transient recovery deviation % 3.3V output models only ±5 Isolation Specifications Parameters Conditions Typical Rated Units Tested I/O voltage 60 sec 1600 & 3000 VDC Tested metal case to Input and Output 60 sec 1000 VDC Resistance >1000 MOhm Capacitance For 1600VDC Isolation models 1500 pF For 3000VDC Isolation models 1000 Output Specifications Parameters Conditions Typical Maximu m Units Voltage accuracy ±1 % 48V nom 3000VDC models only ±1.5 Over voltage protection Zener Diode Clamp % Over load protection For 1600VDC Isolation models 150 % For 3000VDC Isolation models 160 For 3000VDC Isolation models 48V nom 170 Short Circuit protection Continuous Short circuit restart Auto-Recovery Line voltage regulation HL-LL 1600VDC models ±0.2 % of Vin HL-LL 3000VDC models ±0.5 Load voltage regulation 0 – 100% load ±0.5 % Cross regulation (Dual) 25% load on one output - 100% load on second load ±5 % Temperature coefficient ±0.02 %/ oC Ripple & Noise* 20MHz Bandwidth 75 mV p-p Minimum Load Current 0 % of Max *Measured with 1uF ceramic capacitor.
8Watt | DC-DC Converter www.aimtec.com Tel: +1 514 620 2722 Toll free: + 1 888 9 AIMTEC (924 6832) F 051e R12.F 3 of 4 North America only General Specifications Parameters Conditions Typical Maximum Units Switching frequency 100% load 1600VDC models 270 KHz 24 & 48V nom 3000VDC models 330 110V 220 Operating temperature Derating above +70 -40 to +85 oC Storage temperature -55 to +125 oC Maximum case temperature 105 oC Cooling Free air convection Humidity 95 % RH Case material Nickel plated Cooper Weight 18 g MTBF > 1,000,100 hours(MIL-HDBK-217F , Ground Benign, t=+25oC) Maximum soldering temperature 1.5mm from case for 10sec 260 oC Safety Specifications Parameters Agency Approval CE (1600VDC models) Standards for 1600VDC models EN55022 Class A, EN55024 IEC61000-4-2, Perf. Criteria B IEC61000-4-3, Perf. Criteria A IEC61000-4-4, Perf. Criteria B (external 330uF/100V cap required) IEC61000-4-5, Perf. Criteria B (external 330uF/100V cap required) IEC61000-4-6, Perf. Criteria A IEC61000-4-8, Perf. Criteria A Meets IEC/EN60950-1 Pin Out Specifications Dimensions Pin Single Dual
1 Remote On/Off Remote On/Off
9 No Pin Common
11 N.C. -V Output 14 +V Output +V Output 16 -V Output Common 22 +V Input +V Input 23 +V Input +V Input N.C.: Not Connected Bottom View 20.30 (0.80) 2.54 (0.10) 5.08 (0.20)Printed Face 10.20 (0.40) 3.05 (0.12) 0.50 (0.02) 15.20 (0.60) 31.80 (1.25) 23 9 11 14162223 0.50 (0.02)
8Watt | DC-DC Converter www.aimtec.com Tel: +1 514 620 2722 Toll free: + 1 888 9 AIMTEC (924 6832) F 051e R12.F 4 of 4 North America only Derating Recommended Circuits for 1600VDC isolated models C1 L C2 2.2uF, 100V 12uH 2.2uF, 100V 330uF, 100V NOTE: 1. Datasheets are updated as needed and as such, specifications are subject to change without notice. Once printed or downloaded, datasheets are no longer controlled by Aimtec; refer to www.aimtec.com for the most current product specifications. 2. Product labels shown, including safety agency certifications on labels, may vary based on the date manufactured. 3. Mechanical drawings and specifications are for reference only. 4. All specifications are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at rated output load unless otherwise specified. 5. Aimtec may not have conducted destructive testing or chemical analysis on all internal components and chemicals at the time of publishing this document. CAS numbers and other limited information are considered proprietary and may not be available for release. 6. This product is not designed for use in critical life support systems, equipment used in hazardous environments, nuclear control systems or other such applications which necessitate -4 0 -2 0 02 0 4 0 6 0 80 100 100 Safe Operating Area Output Power (%) Ambient Temperature º C 70 º C