6 Watt | DC-DC Converter

www.aimtec.com Tel: +1 514 620 2722 Toll free: + 1 888 9 AIMTEC (924 6832) F 051e R13 1 of 3 North America only Picture coming soon FEATURES:

  • Wide input voltage range (2:1) • Operating temperature: -40 ºC to +85 ºC
  • Efficiency up to 88% • Low ripple and noise
  • Isolation voltage of 1500VDC • Continuous Short Circuit Protection
  • Output Over Voltage Protection • 1x1” package Models Single output Model Input Voltage (V) Output Voltage (V) Output Current max (mA) Isolation (VDC) Max Capacitive Load(uF) Efficiency (%) AM6C-1203S-NZ 9-18 3.3 1500 1500 1800 76 AM6C-1205S-NZ 9-18 5 1200 1500 1000 81 AM6C-1212S-NZ 9-18 12 500 1500 100 85 AM6C-1215S-NZ 9-18 15 400 1500 100 85 AM6C-1224S-NZ 9-18 24 250 1500 47 86 AM6C-2403S-NZ 18-36 3.3 1500 1500 1800 79 AM6C-2405S-NZ 18-36 5 1200 1500 1000 83 AM6C-2412S-NZ 18-36 12 500 1500 100 87 AM6C-2415S-NZ 18-36 15 400 1500 100 87 AM6C-2424S-NZ 18-36 24 250 1500 47 87 AM6C-4803S-NZ 36-75 3.3 1500 1500 1800 79 AM6C-4805S-NZ 36-75 5 1200 1500 1000 83 AM6C-4812S-NZ 36-75 12 500 1500 100 87 AM6C-4815S-NZ 36-75 15 400 1500 100 88 AM6C-4824S-NZ 36-75 24 250 1500 47 88 Models Dual output Model Input Voltage (V) Output Voltage (V) Output Current max (mA) Isolation (VDC) Max Capacitive Load(uF) Efficiency (%) AM6C-1205D-NZ 9-18 ±5 ±600 1500 470 81 AM6C-1212D-NZ 9-18 ±12 ±250 1500 100 85 AM6C-1215D-NZ 9-18 ±15 ±200 1500 100 85 AM6C-2405D-NZ 18-36 ±5 ±600 1500 470 83 AM6C-2412D-NZ 18-36 ±12 ±250 1500 100 87 AM6C-2415D-NZ 18-36 ±15 ±200 1500 100 87 AM6C-2424D-NZ 18-36 ±24 ±125 1500 47 87 AM6C-4805D-NZ 36-75 ±5 ±600 1500 470 83 AM6C-4812D-NZ 36-75 ±12 ±250 1500 100 87 AM6C-4815D-NZ 36-75 ±15 ±200 1500 100 88 AM6C-4824D-NZ 36-75 ±24 ±125 1500 47 88 NOTE: All specifications in this datasheet are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at rated output load unless otherwise specified. Input Specifications Parameters Nominal Typical Maximum Units Voltage range 12 9-18 VDC 24 18-36 48 36-75 Filter π(Pi) Network Start up time ms Absolute Maximum Rating -0.7 – 25 -0.7 – 50 -0.7 - 100 VDC

www.aimtec.com Tel: +1 514 620 2722 Toll free: + 1 888 9 AIMTEC (924 6832) F 051e R13 2 of 3 North America only Input Specifications (continued) Parameters Nominal Typical Maximum Units Peak Input Voltage time 1 s No Load Input Current mA Input reflected current 20 mA Isolation Specifications Parameters Conditions Typical Rated Units Tested I/O voltage 1 min, ≤1mA 1500 VDC Resistance Isolation 500VDC >1000 MOhm Capacitance 100kHz, 0.1V 1000 pF Output Specifications Parameters Conditions Typical Maximum Units Voltage accuracy ±2 % Voltage balance (Dual Output Models) Balanced Load ±1.5 % Cross Regulation (Dual Output Models) 25% load on one output - 100% load on second load ±5 % Over voltage protection 110-140 % of Vout Short Circuit protection Continuous Short circuit restart Auto recovery Line voltage regulation (Single) LL-HL, full load ±0.5 % of Vin Line voltage regulation (Dual) LL-HL, full load ±1 % of Vin Load voltage regulation 5% -100% load ±1 % Temperature coefficient Full load ±0.03 %/oC Ripple & Noise 20MHz Bandwidth 75 mV p-p Transient recovery time 25% load step change 500 µs Transient recovery deviation 25% load step change ±5 % General Specifications Parameters Conditions Typical Maximum Units Switching frequency 100% load 300 KHz Operating temperature With derating above 71ºC -40 to +85 oC Storage temperature -55 to +125 oC Maximum case temperature 105 oC Cooling Free convection Humidity 95 % RH Case material Aluminum alloy Weight 13 g Dimensions (L x W x H) 1 x 1 x 0.46 inches 25.40 x 25.40 x 11.70 mm MTBF >1,000,000 hours (MIL-HDBK -217F, Ground Benign, t=+25oC) Maximum soldering temperature 10sec, 1.5mm from case 300 oC Safety Specifications Parameters Standards Information Technology Equipment EN55022 Class B, with the recommended circuit below, EN55024 Electrostatic Discharge Immunity IEC 61000-4-2, Contact ±4KV, Criteria B RF, Electromagnetic Field Immunity IEC 61000-4-3, 10V/m, Criteria A Electrical Fast Transient / Burst Immunity IEC 61000-4-4, ±2KV, Criteria B, with the recommended circuit below Surge Immunity IEC 61000-4-5, ±2KV, Criteria B, with the recommended circuit below RF, Conducted Disturbance Immunity IEC 61000-4-6, 3 Vrms, Criteria A

www.aimtec.com Tel: +1 514 620 2722 Toll free: + 1 888 9 AIMTEC (924 6832) F 051e R13 3 of 3 North America only Pin Out Specifications Dimensions Pin Single Dual 1 +V Input +V Input 2 -V Input -V Input 3 +V Output +V Output

4 No pin Common

  • 40 - 20 0 20 40 60 80 100 100 Safe Operating Area Output Power (%) Ambient Temperature º C Free Air Convection 71º C Notes: All dimensions are typical in millimeters (inches). Case Tolerance ±0.25 (±0.01) Pin diameter tolerance ±0.1 (±0.004) Pin height tolerance ±0.5 (±0.02) EMC recommended circuit 12V input 24V input 48V input MOV S14K20 S14K35 S14K60 C1 680µF/25V 330µF/50V 330µF/100V C2 1µF/50V 1µF/50V 1µF/100V C3 10µF/50V 10µF/50V 10µF/100V NOTE: 1. Datasheets are updated as needed and as such, specifications are subject to change without notice. Once printed or downloaded, datasheets are no longer controlled by Aimtec; refer to www.aimtec.com for the most current product specifications. 2. Product labels shown, including safety agency certifications on labels, may vary based on t he date manufactured. 3. Mechanical drawings and specifications are for reference only. 4. All specifications are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at rated output load unless otherwise specified. 5. Aimtec may not have conducted destructive testing or chemical analysis on all internal components and chemicals at the time of publishing this document. CAS numbers and other limited information are considered proprietary and may not be available for rel ease. 6. This product is not designed for use in critical life support systems, equipment used in hazardous environments, nuclear control s ystems or other such applications which necessitate 25.40 (1.00) 2.54 (0.10) 20.32 (0.80) 2.54 (0.10) 10.16 (0.40) 5.08 (0.20) 2.54 (0.10)10.16 (0.40) 10.16 (0.40) 25.40 (1.00)11.70 (0.46) Printed Face 1.00 (0.39) Top View Side View 2.54 (0.10) Input Input 3 4 5 +V Output Common -V Output Bottom View 4.10 (0.16) DC-DC Converter +Vin -Vin +Vo -Vo CY1 1nF/2KV CY2 1nF/2KV LDM 4.7µH MOV