60 Watt | DC-DC Converter

www.aimtec.com Tel: +1 514 620 2722 Toll free: + 1 888 9 AIMTEC (924 6832) F 051e R12.A 1 of 5 North America only FEATURES:  Wide Input 2:1 Range  Adjustable Output Voltage  No Minimum Load Required  Remote ON/OFF Function  Soft Start  Operating temperature -40 oC to + 85oC  Efficiency up to 91%  Over Load, Voltage, Temperature & Short Circuit Protection Models Single output Model Input Voltage (V) Output Voltage (V) Output Current max (A) Isolation (VDC) Efficiency (%) AM60U-2403SZ 18-36 3.3 14 1600 91 AM60U-2405SZ 18-36 5 12 1600 91 AM60U-2412SZ 18-36 12 5 1600 90 AM60U-2415SZ 18-36 15 4 1600 90 AM60U-4803SZ 36-75 3.3 14 1600 91 AM60U-4805SZ 36-75 5 12 1600 91 AM60U-4812SZ 36-75 12 5 1600 91 AM60U-4815SZ 36-75 15 4 1600 91 Add suffix “-K” for optional heatsink NOTE: All specifications in this datasheet are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at rated output load unless otherwise specified. Input Specifications Parameters Nominal Typical Maximum Units Voltage range 24 18-36 VDC 48 36-75 Filter π(Pi) Network Start up time 20 ms Absolute Maximum Rating 24 ~0.7~50 VDC 48 ~0.7~100 Peak Input Voltage time 100 ms Input reflected ripple current 20 mA p-p Under Voltage Lockout (On/Off) (24V model) 17.8 (48V model) 33.5

30.5 VDC

CNTL On / OFF ON: 3 ~12Vdc or Open Circuit OFF: 0 ~ 1.2Vdc or Short pin 2 & 3 (idle current 5mA typical) VDC Isolation Specifications Parameters Conditions Typical Rated Units Tested I/O voltage 3 sec 1600 VDC Case Input & Output 3 sec 1600 VDC Resistance >1000 MOhm Capacitance 2000 pF Output Specifications Parameters Conditions Typical Maximum Units Voltage accuracy ±1 % Over voltage protection Zener Diode Clamp Over load protection Hiccup 135 % Short Circuit protection Continuous Short circuit restart Auto-Restart Thermal shutdown On Case 120 ºC Line voltage regulation ±0.5 % of Vin Click on Series name for product info on aimtec.com

www.aimtec.com Tel: +1 514 620 2722 Toll free: + 1 888 9 AIMTEC (924 6832) F 051e R12.A 2 of 5 North America only Output Specifications (continued) Parameters Conditions Typical Maximum Units Load voltage regulation 0% to 100% Full Load ±0.5 % Temperature coefficient ±0.02 %/ oC Ripple & Noise 20MHz Bandwidth (3.3 & 5V) 20MHz Bandwidth (12 & 15V) 100 mV p-p Transient Response Deviation ±3 % of Max Transient Recovery 250 µsec Voltage adjustment range ±10 % General Specifications Parameters Conditions Typical Maximum Units Switching frequency 100% load 270 KHz Operating temperature With derating above 40 oC (see graph below) -40 to +85 oC Storage temperature -40 to +125 oC Maximum case temperature 110 oC Derating Above 40 oC 2 %/ oC Cooling Free Air Convection Humidity 95 % RH Case material Nickel – coated Copper Weight 70 g MTBF >110 000 hrs ( MIL-HDBK-217 F at +25 oC) Maximum soldering temperature 1.5mm from case for 10 sec 260 oC Safety Specifications Parameters Standards Designed to meet IEC 60950- 1:2001 and EN55022:2006 + A1:2007, Class B Internal EMI Filter designed to meet EN55022 Class A Pin Out Specifications Pin Single 1 +V Input 2 -V Input

3 On/Off Control

8 Trim

www.aimtec.com Tel: +1 514 620 2722 Toll free: + 1 888 9 AIMTEC (924 6832) F 051e R12.A 3 of 5 North America only Dimensions 50.80 (2.00) 50.80 (2.00) Bottom View 45.72 (1.80) Dimensions mm(inch ) Case Tolerance ±0.50 (±0.02) Pin Pitch Tolerance ±0.35 (±0.014) 5.08 (0.20) 10.16 (0.40) 2.54 (0.10) 2.54 (0.1) 7.62 (0.30) 5.08 (0.20)7.62 (0.30) 5.08 (0.20) 32.98 (1.30) 27.90 (1.10) 10.20 (0.40) Ø 1.00 (0.04) Printed Face 6.00 (0.24) Dimensions with Optional Heatsink Notes: Add “-K” suffix for ordering, heatsink is affixed with thermally dissipative adhesive tape. See derating graph for temperature performance. Heatsink material is anodized (black) aluminum, adds weight 22g to total mass (70g). Thermal impedance of converter is: without heatsink 11Ԩ/W and 8.4Ԩ/W with heatsink.

www.aimtec.com Tel: +1 514 620 2722 Toll free: + 1 888 9 AIMTEC (924 6832) F 051e R12.A 4 of 5 North America only Derating Extended temperature performance can be achieved with optional heatsink. (add suffix “–K” to part number) Trimming AM60U-xx03SZ AM60U-xx05SZ % Trim Trim-up KΩ Trim- down KΩ % Trim Trim-up KΩ Trim- down KΩ 1 544.6 315.9 1 244.5 230.6 2 184.0 172.3 2 113.8 106.2 3 103.3 112.5 3 70.6 64.3 4 67.7 79.8 4 49.1 43.3 5 47.7 59.2 5 36.3 30.6 6 34.8 44.9 6 27.7 22.2 7 25.9 34.5 7 21.6 16.2 8 19.3 26.6 8 17.0 11.7 9 14.2 20.4 9 13.4 8.1 10 10.3 15.3 10 10.6 5.3

www.aimtec.com Tel: +1 514 620 2722 Toll free: + 1 888 9 AIMTEC (924 6832) F 051e R12.A 5 of 5 North America only AM60U-xx12SZ AM60U-xx15SZ % Trim Trim-up KΩ Trim- down KΩ % Trim Trim-up KΩ Trim- down KΩ 1 371.4 327.4 1 347.3 433.8 2 183.6 142.1 2 178.5 174.9 3 117.6 83.9 3 115.2 100.9 4 83.9 55.5 4 82.1 65.9 5 63.5 38.6 5 61.7 45.5 6 49.8 27.4 6 47.9 32.1 7 39.9 19.5 7 37.9 22.6 8 32.5 13.5 8 30.3 15.6 9 26.7 8.9 9 24.4 10.2 10 22.1 5.3 10 19.7 5.8 NOTE: 1. Datasheets are updated as needed and as such, specifications are subject to change without notice. Once printed or downloaded, datasheets are no longer controlled by Aimtec; refer to www.aimtec.com for the most current product specifications. 2. Product labels shown, including safety agency certifications on labels, may vary based on the date manufactured. 3. Mechanical drawings and specifications are for reference only. 4. All specifications are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at rated output load unless otherwise specified. 5. Aimtec may not have conducted destructive testing or chemical analysis on all internal components and chemicals at the time of publishing this document. CAS numbers and other limited information are considered proprietary and may not be available for release. 6. This product is not designed for use in critical life support systems, equipment used in hazardous environments, nuclear control systems or other such applications which necessitate