AM60EW-Z AIMTEC | Alldatasheet
Document overview
- Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
- PDF pages: 5
Technical content
60 Watt | DC-DC Converter
www.aimtec.com Tel: +1 514 620 2722 Toll free: + 1 888 9 AIMTEC (924 6832) F 051e R12.C 1 of 5 North America only Picture coming soon FEATURES:
- Wide Input 4:1 Range • Adjustable Output Voltage
- No Minimum Load Required • Remote ON/OFF Function
- Soft Start • Operating temperature -40°C to + 75°C
- Efficiency up to 93%
- 1600 VDC Isolation
- Over Current, Over Voltage, Over Temperature & Continuous Short Circuit Protection Models Single output Model Input Voltage (V) Input Current No load/Full load (mA) Output Voltage (V) Output Current max (A) Max Capacitive load (µF) Efficiency (%) AM60EW-2405SZ 9-36 25/2703 5 12 30,000 93 AM60EW-2412SZ 9-36 25/2703 12 5 5850 93 AM60EW-2415SZ 9-36 25/2688 15 4 3900 93 AM60EW-4805SZ 18-75 25/1344 5 12 30,000 93 AM60EW-4812SZ 18-75 25/1351 12 5 5850 93 AM60EW-4815SZ 18-75 25/1344 15 4 3900 93 Models Dual output Model Input Voltage (V) Input Current No load/Full load (mA) Output Voltage (V) Output Current max (A) Max Capacitive load (µF) Efficiency (%) AM60EW-2412DZ 9-36 40/2747 ±12 ±2.5 ±3900 91 AM60EW-2415DZ 9-36 50/2747 ±15 ±2 ±2400 91 AM60EW-4812DZ 18-75 40/1373 ±12 ±2.5 ±3900 91 AM60EW-4815DZ 18-75 50/1373 ±15 ±2 ±2400 91 Add suffix “-K” for optional heatsink NOTE: All specifications in this datasheet are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at rated output load unless otherwise specified. Input Specifications Parameters Nominal Typical Maximum Units Voltage range 24 9-36 VDC 48 18-75 Filter π(Pi) Network Start up time 60 ms Absolute Maximum Rating 24 50 VDC 48 100 Peak Input Voltage time 100 ms Input reflected ripple current Measured with the referenced circuit 20 mA p-p Under Voltage Lockout (On/Off) (24V model) (48V model) 8.6/7.9 17.8/16 VDC Remote On / OFF Control ON: 3 ~12Vdc or Open Circuit OFF: 0 ~ 1.2Vdc or Short pin 2 & 3 (idle current 5mA typical) VDC Isolation Specifications Parameters Conditions Typical Rated Units Tested I/O voltage 60s 1600 VDC Case Input & Output 60s 1600 VDC Resistance >1000 MOhm Capacitance 2200 pF Click on Series name for product info on aimtec.com
www.aimtec.com Tel: +1 514 620 2722 Toll free: + 1 888 9 AIMTEC (924 6832) F 051e R12.C 2 of 5 North America only Output Specifications Parameters Conditions Typical Maximum Units Voltage accuracy ±1 % Over voltage protection Zener Diode Clamp Over load protection Hiccup 120%~140% Short Circuit protection Indefinite Short circuit restart Thermal shutdown On Case 120 ºC Line voltage regulation ±0.5 % of Vin Load voltage regulation 0% to 100% Full Load, Single Dual Output ±0.5 ±1 % Temperature coefficient ±0.02 %/oC Ripple & Noise 20MHz Bandwidth 100 mV p-p Transient Response Deviation ±3 % of Max Transient Recovery 250 µsec Voltage adjustment range ±10 % General Specifications Parameters Conditions Typical Maximum Units Switching frequency 100% load 225 KHz Operating temperature With derating (see graph below) -40 to +75 oC Storage temperature -55 to +125 oC Maximum case temperature 110 oC Cooling Free Air Convection Humidity 95 % RH Case material Non-conductive Black Plastic (UL94V-0 rated) Weight 45 g MTBF >210 000 hrs (MIL-HDBK-217 F at +25 oC) Maximum soldering temperature 1.5mm from case for 10 sec 260 oC Safety Specifications Parameters Agency approvals CE, UL (pending) Standards EMI - Conducted and radiated emission EN55022, class A (with the recommended EMI circuit), EN55024: 2010 Electrostatic Discharge Immunity IEC 61000-4-2, Criteria A RF, Electromagnetic Field Immunity IEC 61000-4-3, Criteria A Electrical Fast Transient/Burst Immunity IEC 61000-4-4, Criteria A, (with the recommended EMC circuit) Surge Immunity IEC 61000-4-5, Criteria A, (with the recommended EMC circuit) RF, Conducted Disturbance Immunity IEC 61000-4-6, Criteria A Power frequency Magnetic Field Immunity IEC 61000-4-8, Criteria A Pin Out Specifications Pin Single Dual 1 +V Input +V Input 2 -V Input -V Input
3 On/Off Control On/Off Control
6 Trim -V Output
www.aimtec.com Tel: +1 514 620 2722 Toll free: + 1 888 9 AIMTEC (924 6832) F 051e R12.C 3 of 5 North America only Dimensions 2.54 (0.10) 5.08 (0.20) 10.16 (0.40)50.80 (2.00) 25.40 (1.00) Bottom View 2.54 (0.10) 2.54 (0.10) 11.50 (0.45) 10.16 (0.40) 10.16 (0.40) 6.00 (0.24) 5.08 (0.20) Notes: All dimensions are typical in millimeters (inches). Pin Pitch and Length Tolerance: ±0.35 (±0.014) Pin Diameter: ±0.05 (±0.002) Case Tolerance ±0.50 (±0.02) Stand-off Tolerance: ±0.10 (±0.004) 5.08 (0.20) 0.50 (0.02) ᴓ1.00 (0.04) Dimensions with Optional Heatsink Notes: Add “-K” suffix for ordering, heatsink is affixed with thermally dissipative adhesive tape. See derating graph for temperature performance. Heatsink material is anodized (black) aluminum, adds weight 11g to total mass (56g). Thermal impedance of converter is: without heatsink 9.5°C/W and 8.5°C/W with heatsink. Derating AM60EW-2405SZ Others - 40 - 20 0 20 40 60 80 100 100 Safe Operating Area Output Power (%) Ambient Temperature º C Free Air Convection 52º C with heat sink 45º C without heat sink 45 52 SIDE 17.6 (0.69) 50.8 (2.0) END 25.4 (1.0) - 40 - 20 0 20 40 60 80 100 100 Safe Operating Area Output Power (%) Ambient Temperature º C Free Air Convection 57º C with heat sink 50º C without heat sink 50 57
www.aimtec.com Tel: +1 514 620 2722 Toll free: + 1 888 9 AIMTEC (924 6832) F 051e R12.C 4 of 5 North America only Extended temperature performance can be achieved with optional heatsink. (add suffix “–K” to part number). Trimming Leave open if not used. AM60EW-xx05SZ Trim down % 1 2 3 4 5 6 7 8 9 10 Trim up % 1 2 3 4 5 6 7 8 9 10 AM60EW-xx12SZ Trim down % 1 2 3 4 5 6 7 8 9 10 Trim up % 1 2 3 4 5 6 7 8 9 10 AM60EW-xx15SZ Trim down % 1 2 3 4 5 6 7 8 9 10 Trim up % 1 2 3 4 5 6 7 8 9 10
www.aimtec.com Tel: +1 514 620 2722 Toll free: + 1 888 9 AIMTEC (924 6832) F 051e R12.C 5 of 5 North America only EMI recommended circuit Single output models Dual output models DC/DC Converter +V input -V input +V output Load -V output C2C1 EFT/Surge Circuit recommendation NOTE: 1. Datasheets are updated as needed and as such, specifications are subject to change without notice. Once printed or downloaded, datasheets are no longer controlled by Aimtec; refer to www.aimtec.com for the most current product specifications. 2. Product labels shown, including safety agency certifications on labels, may vary based on the date manufactured. 3. Mechanical drawings and specifications are for reference only. 4. All specifications are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at rated output load unless otherwise specified. 5. Aimtec may not have conducted destructive testing or chemical analysis on all internal components and chemicals at the time of publishing this document. CAS numbers and other limited information are considered proprietary a nd may not be available for release. 6. This product is not designed for use in critical life support systems, equipment used in h azardous environments, nuclear control systems or other such applications which necessitate Vin single output C1, C2 L1, L2 C3 C4, C5 24V 4.7 µF / 50V 12 µH 470 pF / 2KV 1 nF / 2KV 48V 1.5 µF / 100V Vin dual output C1, C2 C3 C4 24V 4.7 µF / 50V 220 pF / 2KV 1.5 nF / 2KV 48V 1.5 µF / 100V Vin C1 D1 24V 330 µF / 100V TVS 58V, 3KW 48V TVS 120V, 3KW DC/DC Converter +V input -V input +V output Load -V output C2C1 Common Load DC/DC Converter +Vin -Vin +Vout -Vout LoadC1