4 Watt | DC-DC Converter
www.aimtec.com Tel: +1 514 620 2722 Toll free: + 1 888 9 AIMTEC (924 6832) F 051e R12 1 of 4 North America only FEATURES:
- RoHS compliant • Operating temperature -40oC to + 85oC
- ±20% Input voltage range • 5KVAC highest reinforced input/ output isolation
- Low ripple and noise • Pin compatible with multiple manufacturers
- High efficiency up to 81% • Continuous short circuit protection Models Single output Model Input Voltage (V) Output Voltage (V) Output Current max (mA) Isolation (VAC) Efficiency (%) AM4N-0503SH50Z 4-6 3.3 700 5000 74 AM4N-0505SH50Z 4-6 5 700 5000 78 AM4N-0512SH50Z 4-6 12 291 5000 80 AM4N-0515SH50Z 4-6 15 233 5000 79 AM4N-1203SH50Z 9.6-14.4 3.3 700 5000 76 AM4N-1205SH50Z 9.6-14.4 5 700 5000 80 AM4N-1212SH50Z 9.6-14.4 12 291 5000 81 AM4N-1215SH50Z 9.6-14.4 15 233 5000 81 NOTE: All specifications in this datasheet are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at rated output load unless otherwise specified. Input Specifications Parameters Nominal Typical Maximum Units Voltage range 5 4-6 9.6-14.4 VDC Filter Capacitors Start up time 75 ms Absolute Maximum Rating 5 Vin
12 Vin
No Load Input Current 80 115 mA Input reflected current(pk-pk) 35 mA Isolation Specifications Parameters Conditions Typical Maximum Units Tested I/O voltage 3 sec 5000 VAC Resistance 1000 MOhm Capacitance 50 pF Output Specifications Parameters Conditions Typical Maximum Units Voltage accuracy ±2 % Short Circuit protection Continuous Short circuit restart Autorecovery Short Circuit consumption W Line voltage regulation ±0.2 % of Vin Load voltage regulation From 10% to 100% Load ±0.5 % Temperature coefficient ±0.02 %/oC Ripple & Noise 20MHz Bandwidth 85 mV p-p Minimum Load Current 10 % of Max General Specifications Parameters Conditions Typical Maximum Units Switching frequency 100% load 570 KHz Operating temperature -40 to +85 (full load without derating) oC Storage temperature -55 to +125 oC
www.aimtec.com Tel: +1 514 620 2722 Toll free: + 1 888 9 AIMTEC (924 6832) F 051e R12 2 of 4 North America only General Specifications (continued) Parameters Conditions Typical Maximum Units Maximum case temperature 100 oC Derating None %/ oC Cooling Natural Convection Humidity 95 % RH Case material Non Conductive Black Plastic (UL94V-0 rated) Weight 12.5 g MTBF > 1 000 000 hrs (MIL-HDBK -217F, Ground Benign, t=+25oC) Maximum soldering temperature 1.5mm from case for 10sec 260 oC Safety Specifications Parameters Agency Approvals CE Standards EN 55022 Class A EN 55024 IEC 61000-4-2 IEC 61000-4-3 IEC 61000-4-4 IEC 61000-4-5 IEC 61000-4-6 IEC 61000-4-8 NOTE: also designed to meet IEC 60601-1 Pin Out Specifications N.C.: No connection Pin Single 2 -V Input 3 -V Input 11 N.C. 14 +V Output 16 -V Output
22 V+ Input
23 V+ Input
www.aimtec.com Tel: +1 514 620 2722 Toll free: + 1 888 9 AIMTEC (924 6832) F 051e R12 3 of 4 North America only Dimensions 27.94 (1.10) 20.32 (0.80) 2.54 (0.10) Printed Face Built-in Stand-offs to ease PCB cleaning 10.15 (0.40) 3.05 (0.12) 0.50 (0.02) 15.24 (0.60) 31.75 (1.25) Bottom View 2 3 11 142223 All dimensions are typical: millimeters (inches) Pin Diameter: 0.50 ± 0.05 (0.02 ± 0.002) Pin Pitch Tolerance: ± 0.35 (±0.014) Case Tolerence: ± 0.5 (±0.02) 10 12 15 13 0.25 (0.01) EMI Solution DC/DC Converter +V input -V input +V output Load -V output
www.aimtec.com Tel: +1 514 620 2722 Toll free: + 1 888 9 AIMTEC (924 6832) F 051e R12 4 of 4 North America only EFT/Surge Solution C1 DC/DC Converter +V input -V input +V output Load -V output NOTE: 1. Datasheets are updated as needed and as such, specifications are subject to change without notice. Once printed or downloaded, datasheets are no longer controlled by Aimtec; refer to www.aimtec.com for the most current product specifications. 2. Product labels shown, including safety agency certifications on labels, may vary based on the date manufactured. 3. Mechanical drawings and specifications are for reference only. 4. All specifications are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at rated output load unless otherwise specified. 5.Aimtec may not have conducted destructive testing or chemical analysis on all internal components and chemicals at the time of publishing this document. CAS numbers and other limited information are considered proprietary and may not be available for release. 6. This product is not designed for use in critical life support systems, equipment used in hazardous environments, nuclear control sy stems or other such applications which necessitate