AM45W-NST AIMTEC | Alldatasheet
Document overview
- Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
- PDF pages: 4
Technical content
45 Watt | DC-DC Converter
www.aimtec.com Tel: +1 514 620 2722 Toll free: + 1 888 9 AIMTEC (924 6832) F 051e R1 1 of 4 North America only FEATURES:
- Super wide 10:1 Input range • High I/O Isolation of 4000VAC
- Extremely High Input range up to 1500VDC • High efficiency of up to 78%
- Continuous Short Circuit protection • Under Voltage Input protection
- Over current and Over Voltage protection • Reversed connection protection Models Dual output Model Input Voltage (V) Output Voltage (V) Output Current max (A) Isolation (VAC) Max Capacitive Load (uF) Efficiency (%) 200 VDC 850 VDC 1400 VDC AM45W-8501515D-NST 150-1500 15/15 1.53/1.53 4000 1500/470 78 78 76 NOTE: All specifications in this datasheet are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at rated output load unless otherwise specified. Input Specifications Parameters Nominal Typical Maximum Units Voltage range 850VDC 150-1500 VDC Input Current
200 VDC 350
850 VDC 90
1500 VDC 50
Inrush current <2ms
200 VDC 30
A
300 VDC 40
850 VDC 100
1500 VDC 180
Input Under voltage lockout 125-140 VDC Absolute Maximum rating 1600 VDC Peak Input Voltage time 1 s Startup time* Full input range, full load 2 s * Cooling time between the power OFF and the next power ON should be over 15s. Isolation Specifications Parameters Conditions Typical Maximum Units Tested I/O voltage 1 min, ≤10mA 4000 VAC Isolation Voltage I/GND & O/GND 1 min, ≤10mA 2500 VAC Isolation Voltage OUT 1/OUT 2 1 min, ≤10mA 4000 VAC Output Specifications Parameters Conditions Typical Maximum Units Voltage accuracy ±1 % Line voltage regulation LL-HL ±1 % of Vin Load voltage regulation 10-100% load ±2 % Over voltage protection 25 VDC Over current protection Hiccup, Auto recovery 110-300 % of Iout Short Circuit protection Continuous, hiccup Short circuit restart Auto recovery Temperature coefficient ±0.02 %/oC Ripple & Noise 20MHz Bandwidth 150 mV p-p Hold up time 300VDC Input 5 ms 8500VDC Input 15
www.aimtec.com Tel: +1 514 620 2722 Toll free: + 1 888 9 AIMTEC (924 6832) F 051e R1 2 of 4 North America only General Specifications Parameters Conditions Typical Maximum Units Switching frequency 100% load 65 KHz Operating temperature See derating curve -40 to 85 °C Storage Temperature -40 to 85 °C Maximum case temperature 95 °C Cooling Free air convection Humidity 95 % RH Altitude 5000 m Case material Metal Weight 520 g MTBF >300,000 hrs (MIL-HDBK -217F, Ground Benign, t=+25°C) Safety Specifications Parameters Standards EMI - Conducted and radiated emission EN55022, class A (with the recommended EMC circuit), EN55024: 2010 Electrostatic Discharge Immunity IEC 61000-4-2: Contact ±6KV/Air ±8KV, Criteria B RF, Electromagnetic Field Immunity IEC 61000-4-3: 10V/m, Criteria A Electrical Fast Transient/Burst Immunity IEC 61000-4-4: ±4KV, Criteria B Surge Immunity IEC 61000-4-5: ±2KV, line to ground ±4KV Criteria B RF, Conducted Disturbance Immunity IEC 61000-4-6: 10Vrms, Criteria A, (with the recommended EMC circuit) Voltage dips, Short Interruptions Immunity IEC 61000-4-11: 0-70%, Criteria B Pin Out Specifications Dimensions: Pin Function 1 -Vin 2 +Vin
3 Ground
Dimensions: mm (inches) Case Tolerance: ±1.00 (±0.04) Torque: Max 0.4 N m Wire wage: 22-12 AWG, 4mm2 144.50 (5.69) 132.00 (5.20) 105.00 (4.13) 85.00 (3.35) LED 40.00 (1.58) Side View
www.aimtec.com Tel: +1 514 620 2722 Toll free: + 1 888 9 AIMTEC (924 6832) F 051e R1 3 of 4 North America only Derating NOTE: Derating is indicated at natural convection. Sufficient air space around is needed. Typical Application circuit DC DC -Vin +Vin + Vout 1 - Vout 2 Dual Output 1µF/50V -Vin +Vin Vout 2 C2 + TVS2 Earth/GND 1µF/50V C4 + Vout 1 + Vout 2 - Vout 1 TVS2 C2, C4 TVS1, TVS2 100 µF / 35V 20V 0 2000 100 Output Power (%) Altitude (m) Altitude Derating curve 5000 - 40 -20 0 20 40 60 80 100 100 Output Power (%) Ambient Temperature º C Free Air Convection Safe Operating Area 150-200VDC - 40 -20 0 20 40 60 80 100 100 Output Power (%) Ambient Temperature º C Free Air Convection Safe Operating Area 200-1500VDC 150 200 1500 100 Safe Operating Area Output Power (%) Free Air Convection at 25°C Input Voltage VDC 1400
www.aimtec.com Tel: +1 514 620 2722 Toll free: + 1 888 9 AIMTEC (924 6832) F 051e R1 4 of 4 North America only Recommended EMC Circuit DC + Vin - Vin Dual OutputFUSE 15A/1500VDC + Vin - Vin LCM 7mH/1A LDM C10 C11 C12 Earth/GND DC + Vout 1 - Vout 2 1µF/ 50V Vout 2 C2 + TVS2 1µF/ 50V C4 + Vout 1 + Vout 2 - Vout 1 TVS2 LDM C2, C4 R1, R2, R3, R4 C5, C6, C7, C8 C9, C10, C11, C12 TVS1, TVS2 330 µH/0.38A 100 µF / 35V 1MΩ / 2W 47 µF / 450VDC 100 nF / 275VAC 20V NOTE: 1. Datasheets are updated as needed and as such, specifications are subject to change without notice. Once printed or downloaded, datasheets are no longer controlled by Aimtec; refer to www.aimtec.com for the most current product specifications. 2. Product labels shown, including safety agency certifications on labels, may vary based on the date manufactured. 3. Mechanical drawings and specifications are for reference only. 4. All specifications are measured at an ambient temperature of 25°C, humidi ty<75%, nominal input voltage and at rated output load unless otherwise specified. 5. Aimtec may not have conducted destructive testing or chemical analysis on all internal components and chemicals at the time of publishing this document. CAS numbers and other limited information are considered proprietary a nd may not be available for release. 6. This product is not designed for use in critical life support systems, equipment used in hazardous environments, nuclear control systems or other such applications which necessitate