40 Watt | DC-DC Converter
www.aimtec.com Tel: +1 514 620 2722 Toll free: + 1 888 9 AIMTEC (924 6832) F 051e R12.B 1 of 3 North America only FEATURES:
- Wide Input 2:1 Range • Adjustable Output Voltage
- Full Internal SMD Technology • Remote ON/OFF Function
- 1600 VDC Isolation • Over Load, Voltage & Short Circuit Protection
- Efficiency up to 89% • Operating temperature -40 oC to + 85oC Models Single output Model Input Voltage (V) Output Voltage (V) Output Current max (A) Isolation (VDC) Efficiency (%) AM40U-1203SAZ 9-18 3.3 8 1600 85 AM40U-1205SAZ 9-18 5 8 1600 86 AM40U-1212SAZ 9-18 12 3.3 1600 86 AM40U-1215SAZ 9-18 15 2.6 1600 87 AM40U-2403SAZ 18-36 3.3 8 1600 86 AM40U-2405SAZ 18-36 5 8 1600 88 AM40U-2412SAZ 18-36 12 3.3 1600 88 AM40U-2415SAZ 18-36 15 2.6 1600 89 AM40U-4803SAZ 36-75 3.3 8 1600 87 AM40U-4805SAZ 36-75 5 8 1600 88 AM40U-4812SAZ 36-75 12 3.3 1600 89 AM40U-4815SAZ 36-75 15 2.6 1600 89 NOTE: All specifications in this datasheet are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at rated output load unless otherwise specified. Input Specifications Parameters Nominal Typical Maximum Units Voltage range 12 9-18 VDC 24 18-36 48 36-75 Filter π(Pi) Network Start up time 25 ms Absolute Maximum Rating 12 36 VDC 24 50 48 100 Peak Input Voltage time 100 ms Input reflected ripple current 20 mA p-p Isolation Specifications Parameters Conditions Typical Rated Units Tested I/O voltage 3 sec 1600 VDC Resistance >1000 MOhm Capacitance 220 pF Output Specifications Parameters Conditions Typical Maximum Units Voltage accuracy ±2 % Over voltage protection Zener Diode Clamp Over load protection Foldback 135~150 % Short Circuit protection Continuous Short circuit restart Auto-Restart Thermal shutdown On Case 110 ºC Line voltage regulation ±1 % of Vin
www.aimtec.com Tel: +1 514 620 2722 Toll free: + 1 888 9 AIMTEC (924 6832) F 051e R12.B 2 of 3 North America only Output Specifications (continued) Parameters Conditions Typical Maximum Units Load voltage regulation (Single) Iout=10% to 100% ±2 % Temperature coefficient ±0.02 %/ oC Ripple & Noise 20MHz Bandwidth 75 mV p-p Voltage adjustment range ±10 % General Specifications Parameters Conditions Typical Maximum Units Switching frequency 100% load 300 KHz Operating temperature With derating above 55 oC (see graph below) -40 to +85 oC Storage temperature -55 to +125 oC Maximum case temperature 105 oC Derating Above 55 oC 2 %/ oC Cooling Free Air Convection Humidity 95 % RH Case material Nickel – coated Copper Weight 60 g MTBF >1 500 000 hrs ( MIL-HDBK-217 F at +25 oC) Maximum soldering temperature 1.5mm from case for 10 sec 260 oC Transient recovery time 500 uS Transient recovery deviation 25% load step ±4% of Vout Safety Specifications Parameters Standards Designed to meet IEC 60950- 1:2001 and EN55022:2006 + A1:2007, Class B Pin Out Specifications Pin Single 1 +V Input 2 -V Input
3 No Pin
6 On/Off (option)
www.aimtec.com Tel: +1 514 620 2722 Toll free: + 1 888 9 AIMTEC (924 6832) F 051e R12.B 3 of 3 North America only Dimensions Derating Trimming -4 0 -2 0 02 0 4 0 6 0 80 100 100 Safe Operating Area Ambient Temperature º C Free Air Convection 55º C NOTE: 1. Datasheets are updated as needed and as such, specifications are subject to change without notice. Once printed or downloaded, datasheets are no longer controlled by Aimtec; refer to www.aimtec.com for the most current product specifications. 2. Product labels shown, including safety agency certifications on labels, may vary based on the date manufactured. 3. Mechanical drawings and specifications are for reference only. 4. All specifications are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at rated output load unless otherwise specified. 5. Aimtec may not have conducted destructive testing or chemical analysis on all internal components and chemicals at the time of publishing this document. CAS numbers and other limited information are considered proprietary and may not be available for release. 6. This product is not designed for use in critical life support systems, equipment used in hazardous environments, nuclear control systems or other such applications which necessitate