AM2Q-Z_12 AIMTEC | Alldatasheet

Document overview

  • Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
  • PDF pages: 3

Technical content

2 Watt | DC-DC Converter

www.aimtec.com Tel: +1 514 620 2722 Toll free: + 1 888 9 AIMTEC (924 6832) F 051e R12.E 1 of 3 North America only FEATURES:  RoHS Compliant  Operating Temperature -40ºC to 85ºC  Wide 2:1 input range  Input / Output Isolation of 500VAC  High Efficiency up to 83%  No Tantalum capacitors used inside  Continuous short circuit  Over voltage protection Models Single output Model Input Voltage (V) Output Voltage (V) Output Current max (mA) Isolation (VAC) Max Capacitive Load (uF) Efficiency (%) AM2Q-0505SZ 4.5-9 5 300 500 100 73 AM2Q-0512SZ 4.5-9 12 130 500 100 78 AM2Q-0515SZ 4.5-9 15 100 500 100 78 AM2Q-1205SZ 9-18 5 300 500 100 75 AM2Q-1212SZ 9-18 12 130 500 100 80 AM2Q-1215SZ 9-18 15 100 500 100 81 AM2Q-2405SZ 18-36 5 300 500 100 74 AM2Q-2412SZ 18-36 12 130 500 100 78 AM2Q-2415SZ 18-36 15 100 500 100 79 AM2Q-4805SZ 36-75 5 300 500 100 73 AM2Q-4812SZ 36-75 12 130 500 100 78 AM2Q-4815SZ 36-75 15 100 500 100 78 Models Dual output Model Input Voltage (V) Output Voltage (V) Output Current max (mA) Isolation (VAC) Max Capacitive Load (uF) Efficiency (%) AM2Q-0512DZ 4.5-9 ±12 ±65 500 ±100 82 AM2Q-0515DZ 4.5-9 ±15 ±50 500 ±100 81 AM2Q-1212DZ 9-18 ±12 ±65 500 ±100 83 AM2Q-1215DZ 9-18 ±15 ±50 500 ±100 83 AM2Q-2412DZ 18-36 ±12 ±65 500 ±100 81 AM2Q-2415DZ 18-36 ±15 ±50 500 ±100 82 AM2Q-4812DZ 36-75 ±12 ±65 500 ±100 80 AM2Q-4815DZ 36-75 ±15 ±50 500 ±100 79 NOTE: All specifications in this datasheet are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at rated output load unless otherwise specified. Input Specifications Parameters Nominal Typical Maximum Units Voltage range 5 4.5-9 VDC 12 9-18 24 18-36 48 36-75 Filter LC Type Start up time 20 ms No Load Input Current 30 mA Input reflected current 20 mA

www.aimtec.com Tel: +1 514 620 2722 Toll free: + 1 888 9 AIMTEC (924 6832) F 051e R12.E 2 of 3 North America only Isolation Specifications Parameters Conditions Typical Maximum Units Tested I/O voltage 3sec 500 VAC Resistance 50 MOhm Capacitance 500 pF Output Specifications Parameters Conditions Typical Maximum Units Voltage accuracy ±1 % Cross Regulation (Dual Output Models) 25% load on one output / 100% load on the other output ±5 % Over voltage protection Zener Diode Clamp 5 6.2 V 12 15 15 18 ±12 ±15 ±15 ±18 Short Circuit protection Continuous Short circuit restart Auto Recovery Line voltage regulation LL-HL ±0.5 % of Vin Load voltage regulation Load:0-100% unbalanced ±1 % Temperature coefficient ±0.02 %/oC Ripple & Noise 20MHz Bandwidth 50 mV p-p Minimum Load Current 0 % of Max General Specifications Parameters Conditions Typical Maximum Units Switching frequency 100% load 100 KHz Operating temperature (Dual) Derating above 60ºC -40 to +85 oC Operating temperature (Single) No Derating -40 to +85 oC Storage temperature -40 to +125 oC Maximum case temperature 100 oC Cooling Free Air Convection Humidity 95 % RH Case material Nickel Coated Copper Weight 10 g MTBF >1.6Mhrs ( MIL-HDBK -217F, Ground Benign, t=+25°C ) Transient recovery deviation ±3 % Safety Specifications Parameters Standards Designed to meet IEC/EN 60950-1 Pin Out Specifications Pin Single Dual 1 -V Input -V Input 2 +V Input +V Input 3 +V Output +V Output

4 NP Common

NP: Not Populated

www.aimtec.com Tel: +1 514 620 2722 Toll free: + 1 888 9 AIMTEC (924 6832) F 051e R12.E 3 of 3 North America only Dimensions 18.00 (0.70) 6.60 (0.26) 4.40 (0.17) 2.70 (0.11) 2.65 (0.10) 6.35 (0.25) 6.35 (0.25) 6.35 (0.25) 7.00 (0.28) Derating (Dual outputs) NOTE: 1. Datasheets are updated as needed and as such, specifications are subject to change without notice. Once printed or downloaded, datasheets are no longer controlled by Aimtec; refer to www.aimtec.com for the most current product specifications. 2. Product labels shown, including safety agency certifications on labels, may vary based on the date manufactured. 3. Mechanical drawings and specifications are for reference only. 4. All specifications are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at rated output load unless otherwise specified. 5. Aimtec may not have conducted destructive testing or chemical analysis on all internal components and chemicals at the time of publishing this document. CAS numbers and other limited information are considered proprietary and may not be available for release. 6. This product is not designed for use in critical life support systems, equipment used in hazardous environments, nuclear control systems or other such applications which necessitate