DATASHEET SEARCH SITE | WWW.ALLDATASHEET.COM

Document overview

  • Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
  • PDF pages: 3

Technical content

1.5 Watt | DC-DC Converter

www.aimtec.com Tel: +1 514 620 2722 Toll free: + 1 888 9 AIMTEC (924 6832) F 051e R8.F 1 of 3 North America only FEATURES:

  • SMD package • Operating temperature: -40°C to +85°C
  • Ultra Wide (4:1) input range • Regulated single/dual output
  • 1500VDC isolation • MTBF>1,000,000 hours
  • Continuous short circuit protection • RoHS compliant Models: Single output Model Input Voltage(V) Output Voltage (V) Output Current max(mA) Isolation (VDC) Efficiency (%) AM2LW-2403S-NZ 9-36 3.3 455 1500 72 AM2LW-2405S-NZ 9-36 5 300 1500 76 AM2LW-2409S-NZ 9-36 9 167 1500 78 AM2LW-2412S-NZ 9-36 12 125 1500 79 AM2LW-2415S-NZ 9-36 15 100 1500 80 AM2LW-4805S-NZ 18-72 5 300 1500 76 *AM2LW-4809S-NZ 18-72 9 167 1500 78 Models: Dual output Model Input Voltage (V) Output Voltage (V) Output Current max (mA) Isolation (VDC) Efficiency (%) AM2LW-2405D-NZ 9-36 ±5 ±150 1500 74 AM2LW-2412D-NZ 9-36 ±12 ±63 1500 77 AM2LW-2415D-NZ 9-36 ±15 ±50 1500 75 *Not recommended for new design NOTE 1: Add suffix “TR” to a part number when ordering in tape and reel package NOTE 2: Unless otherwise specified, all specifications in this datasheet are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at rated output load. Input Specifications Parameters Nominal Typical Maximum Units Voltage range 24 9-36 18-72 VDC Absolute Maximum Rating 24

80 VDC

Peak Input Voltage time 100 ms Isolation Specifications Parameters Conditions Typical Rated Units Tested I/O voltage 60 sec 1500 VDC Resistance At 500 Vdc 1000 MOhm Capacitance Input to Output 1000 pF Output Specifications Parameters Conditions Typical Maximum Units Voltage accuracy ±5 % Short Circuit protection Continuous Short circuit restart Auto-Recovery Line voltage regulation From Low in to High In ±0.75 % Load voltage regulation (Single) From 10% to 100% load ±1.5 % Load voltage regulation (Dual) From 10% to 100% load Unbalanced load ±5 % Temperature coefficient ±0.03 %/oC Ripple & Noise 20MHz Bandwidth 100 mV p-p Minimum Load Current* 10 % of Max * Operation under 10% load will not damage the converter; h owever, not all specifications will be met. Click on Series name for product info on aimtec.com

www.aimtec.com Tel: +1 514 620 2722 Toll free: + 1 888 9 AIMTEC (924 6832) F 051e R8.F 2 of 3 North America only General Specifications Parameters Conditions Typical Maximum Units Switching frequency 100% load 550 KHz Operating temperature -40 to +85 oC Storage temperature -55 to +125 oC Maximum case temperature 100 oC Derating Above 71º 2.9 %/ oC Cooling Free Air Convection Humidity 95 % RH Case material Plastic (UL94-V0) Weight 5.2 g MTBF >1,000,000 hours(MIL-HDBK -217F, Ground Benign, t=+25ºC) Maximum Soldering Temperature 1.5mm from case for 10 seconds 300 oC Pin Out Specifications Pin Single Dual 1 - Vin - Vin

7 NC NC

8 NC Common

NC – not connected Dimensions A 0.50 (0.02) 1.36 (0.05) MAX 0.50 (0.02) 5.00º angle A 23.86 (0.94) 13.70 (0.54) 7.50 (0.30) 13.10 (0.52) 15.00 (0.59) Top View Front ViewSide View 8.20 (0.32) 17.50 (0.69) 7 8 91016 23.86 (0.94) 1.02 (0.04) 0.50 (0.02) 3.04 (0.12) 2.54 (0.10) 15.24 (0.60) 18.50 (0.73) 2.54 (0.10) 15.24 (0.60) 0.80 (0.03) 0.20 (0.08) Footprint

www.aimtec.com Tel: +1 514 620 2722 Toll free: + 1 888 9 AIMTEC (924 6832) F 051e R8.F 3 of 3 North America only Recommended Filter Circuit All the AM2LW-Z Series have been tested with the above recommended test circuit. This series should be tested under load. If it is necessary to further decrease the input/output ripple, the value of the filter capacitor can be increased; a capacitor with a low ESR should be used. Excessive filter capacitance can cause start up problems with the converter. In general, the recommended capacitance values are: Cin: 10μF~47μF Cout: 10μF/100mA Refer to table below for maximum capacitor values: External Capacitor Value Single Output Vout (VDC) Cout (uF) Dual Output Vout (VDC) Cout (uF) 5 1000 ±5 ±680 12 470 ±12 ±330 15 330 ±15 ±220 Derating Free Air Convection - 40 - 20 0 20 40 60 80 100 100 Safe Operating Area Output Power (%) Ambient Temperature º C 71 Cº NOTE: 1. Datasheets are updated as needed and as such, specifications are subject to change without notice. Once printed or downloaded, datasheets are no longer controlled by Aimtec; refer to www.aimtec.com for the most current product specifications. 2. Product labels shown, including safety agency certifications on labels, may vary based on the date manufactured. 3.Mechanical drawings and specifications are for reference only. 4.All specifications are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at rated output load unless otherwise specified. 5.Aimtec may not have conducted destructive testing or chemical analysis on all internal components and chemicals at the time of publishing this document. CAS numbers and other limi ted information are considered proprietary and may not be available for release. 6. This product is not designed for use in critical life support systems, equipment used in hazardous environments, nuclear control s ystems or other such applications which necessitate DC DC + Vin - Vin +Cin +Cout +Cout +Vout -Vout Common Dual Output DC DC + Vin - Vin +Cin +Cout +Vout - Vout Single Output