2 Watt | DC-DC Converter
www.aimtec.com Tel: +1 514 620 2722 Toll free: + 1 888 9 AIMTEC (924 6832) F 051e R8.C 1 of 4 North America only FEATURES:
- SMD package • Operating temperature: -40°C to +85°C
- Wide (2:1) input range • Regulated single/dual output
- 1500VDC isolation • MTBF>1,000,000 hours
- Continuous short circuit protection • RoHS compliant Models Single output Model Input Voltage (V) Output Voltage (V) Output Current max (mA) Isolation (VDC) Efficiency (%) AM2LV-1203S-NZ 9-18 3.3 500 1500 70 AM2LV-1205S-NZ 9-18 5 400 1500 74 AM2LV-1209S-NZ 9-18 9 222 1500 76 AM2LV-1212S-NZ 9-18 12 167 1500 78 AM2LV-1215S-NZ 9-18 15 133 1500 79 AM2LV-2403S-NZ 18-36 3.3 500 1500 72 AM2LV-2405S-NZ 18-36 5 400 1500 76 AM2LV-2409S-NZ 18-36 9 222 1500 78 AM2LV-2412S-NZ 18-36 12 167 1500 80 AM2LV-2415S-NZ 18-36 15 133 1500 80 Models Dual output Model Input Voltage (V) Output Voltage (V) Output Current max (mA) Isolation (VDC) Efficiency (%) AM2LV-1205D-NZ 9-18 ±5 ±200 1500 74 AM2LV-1209D-NZ 9-18 ±9 ±111 1500 76 AM2LV-1212D-NZ 9-18 ±12 ±83 1500 78 AM2LV-1215D-NZ 9-18 ±15 ±67 1500 80 AM2LV-2405D-NZ 18-36 ±5 ±200 1500 74 AM2LV-2409D-NZ 18-36 ±9 ±111 1500 76 AM2LV-2412D-NZ 18-36 ±12 ±83 1500 78 AM2LV-2415D-NZ 18-36 ±15 ±67 1500 80 NOTE: Unless otherwise specified, all specifications are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at rated output load. Input Specifications Parameters Nominal Typical Maximum Units Voltage range 12 9-18 18-36 VDC Absolute Maximum Rating 12
40 VDC
Peak Input Voltage time 100 ms Isolation Specifications Parameters Conditions Typical Rated Units Tested I/O voltage 60 sec 1500 VDC Resistance At 500 Vdc 1000 MOhm Capacitance Input to Output 85 pF
www.aimtec.com Tel: +1 514 620 2722 Toll free: + 1 888 9 AIMTEC (924 6832) F 051e R8.C 2 of 4 North America only Output Specifications Parameters Conditions Typical Maximum Units Voltage accuracy ±5 % Short Circuit protection Continuous Short circuit restart Auto-Recovery Line voltage regulation (Single) From Low in to High In ±0.5 % Load voltage regulation (Single) From 10% to 100% load ±1 % Load voltage regulation (Dual) From 10% to 100% load Each output loaded within 5% of each other ±5 % Temperature coefficient ±0.03 %/ oC Ripple & Noise * 20MHz Bandwidth with 10% load 75 mV p-p Minimum Load Current** 10 % of Max * Test Ripple & Noise by “Parallel Cable Method” as described in Application Note “Ripple and Noise Measurement of Brick & POL DC-DC Converters” available on Aimtec’s website www.aimtec.com. Converters are designed to operate with a minimum load of 10%. If converter is operated with a load less than 10% the ripple will increase. ** Operation under 10% load will not damage the converter; However, not all specifications will be met. General Specifications Parameters Conditions Typical Maximum Units Switching frequency 100% load 300 KHz Operating temperature -40 to +85 oC Storage temperature -55 to +125 oC Maximum case temperature oC Derating Above 71º 2.9 %/ oC Cooling Free Air Convection Humidity 95 % RH Case material Plastic (UL94-V0) Weight 5.2 g MTBF >1,000,000 hours (MIL-HDBK -217F, Ground Benign, t=+25ºC) Maximum Soldering Temperature 1.5mm from case for 10 seconds 245 oC Pin Out Specifications Pin Single Dual 1 - Vin - Vin
7 NC NC
8 NC Common
NC – not connected
www.aimtec.com Tel: +1 514 620 2722 Toll free: + 1 888 9 AIMTEC (924 6832) F 051e R8.C 3 of 4 North America only Dimensions A 0.50 (0.02) 1.36 (0.05)MAX 0.50 (0.02) 5.00º angle A 23.86 (0.94) 13.70 (0.54) 7.50 (0.30) 13.10 (0.52) 15.00 (0.59) Top View Front ViewSide View 8.20 (0.32) 17.50 (0.69) 7 8 91016 23.86 (0.94)1.02 (0.04) 0.50 (0.02) 3.04 (0.12) 2.54 (0.10) 15.24 (0.60) 18.50 (0.73) 2.54 (0.10) 15.24 (0.60) 0.80 (0.03) 2.4 (0.08) Footprint
www.aimtec.com Tel: +1 514 620 2722 Toll free: + 1 888 9 AIMTEC (924 6832) F 051e R8.C 4 of 4 North America only Recommended Filter Circuit All the AM2LV-Z Series have been tested with the above recommended test circuit. This series should be tested under load. If it is necessary to further decrease the input/output ripple, the value of the filter capacitor can be increased; a capacitor with a low ESR should be used. Excessive filter capacitance can cause start up problems with the converter. In general, the recommended capacitance values are: Cin: 12V input 100μF, 24V input 10μF~47μF Cout: 10μF/100mA Refer to table below for maximum capacitor values: External Capacitor Value Single Output Vout (VDC) Cout (uF) Dual Output Vout (VDC) Cout (uF) 3.3 2200 ±5 ±680 5 1000 ±9 ±470 9 680 ±12 ±330 12 470 ±15 ±220 15 330 Derating NOTE: 1. Datasheets are updated as needed and as such, specifications are subject to change without notice. Once printed or downloaded, datasheets are no longer controlled by Aimtec; refer to www.aimtec.com for the most current product specifications. 2. Product labels shown, including safety agency certifications on labels, may vary based on the date manufactured. 3. Mechanical drawings and specifications are for reference only. 4. All specifications are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at rated output load unless otherwise specified. 5. Aimtec may not have conducted destructive testing or chemical analysis on all internal components and chemicals at the time of publishing this document. CAS numbers and other limited information are considered proprietary and may not be available for release. 6. This product is not designed for use in critical life support systems, equipment used in hazardous environments, nuclear control systems or other such applications which necessitate DC DC + Vin - Vin +Cin +Cout +Cout +Vout -Vout Common Dual Output DC DC + Vin - Vin +Cin +Cout +Vout - Vout Single Output