2 Watt | DC-DC Converter
www.aimtec.com Tel: +1 514 620 2722 Toll free: + 1 888 9 AIMTEC (924 6832) F 051e R12.H 1 of 5 North America only FEATURES: Low Profile SMD (Surface Mount Device) MTBF>1,000,000 hours 1000VDC & 6000VDC Isolation Operating temperature: -40°C to +85°C Industry Standard Pinout High Efficiency up to 85% Unregulated Single, Dual, Dual Separated Output Models Models Single output Model Input Voltage (V) Output Voltage (V) Output Current max (mA) Isolation (VDC) Efficiency (%) AM2L-0505S-NZ 4.5-5.5 5 400 1000 80 AM2L-0509S-NZ 4.5-5.5 9 222 1000 82 AM2L-0512S-NZ 4.5-5.5 12 167 1000 84 AM2L-0515S-NZ 4.5-5.5 15 133 1000 84 AM2L-1205S-NZ 10.8-13.2 5 400 1000 82 AM2L-1209S-NZ 10.8-13.2 9 222 1000 83 AM2L-1212S-NZ 10.8-13.2 12 167 1000 85 AM2L-1215S-NZ 10.8-13.2 15 133 1000 85 AM2L-0505SH60-NZ 4.5-5.5 5 400 6000 76 AM2L-0512SH60-NZ 4.5-5.5 12 167 6000 79 AM2L-0515SH60-NZ 4.5-5.5 15 133 6000 78 AM2L-1205SH60-NZ 10.8-13.2 5 400 6000 76 AM2L-1212SH60-NZ 10.8-13.2 12 167 6000 80 AM2L-1215SH60-NZ 10.8-13.2 15 133 6000 79 AM2L-2405SH60-NZ 21.6-26.4 5 400 6000 77 AM2L-2412SH60-NZ 21.6-26.4 12 167 6000 80 AM2L-2415SH60-NZ 21.6-26.4 15 133 6000 78 Models Dual output Model Input Voltage (V) Output Voltage (V) Output Current max (mA) Isolation (VDC) Efficiency (%) AM2L-0505D-NZ 4.5-5.5 ±5 ±200 1000 82 AM2L-0509D-NZ 4.5-5.5 ±9 ±111 1000 83 AM2L-0512D-NZ 4.5-5.5 ±12 ±83 1000 84 AM2L-0515D-NZ 4.5-5.5 ±15 ±67 1000 82 AM2L-1205D-NZ 10.8-13.2 ±5 ±200 1000 83 AM2L-1209D-NZ 10.8-13.2 ±9 ±111 1000 84 AM2L-1212D-NZ 10.8-13.2 ±12 ±83 1000 84 AM2L-1215D-NZ 10.8-13.2 ±15 ±67 1000 85 Models Dual Separated output Model Input Voltage (V) Output Voltage (V) Output Current max (mA) Isolation (VDC) Efficiency (%) AM2L-050505D-NZ 4.5-5.5 5/5 200/200 1000 82 AM2L-050909D-NZ 4.5-5. 5 9/9 112/112 1000 83 AM2L-051515D-NZ 4.5-5.5 15/15 67/67 1000 85 AM2L-120505D-NZ 10.8-13.2 5/5 200/200 1000 82 AM2L-120909D-NZ 10.8-13.2 9/9 112/112 1000 83 AM2L-121515D-NZ 10.8-13.2 15/15 67/67 1000 85 NOTE: All specifications in this datasheet are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at rated output load unless otherwise specified.
www.aimtec.com Tel: +1 514 620 2722 Toll free: + 1 888 9 AIMTEC (924 6832) F 051e R12.H 2 of 5 North America only Input Specifications Parameters Nominal Typical Maximum Units Voltage range 5 4.5-5.5 VDC 12 10.8-13.2 24 21.6-26.4 Isolation Specifications Parameters Conditions Typical Rated Units Tested I/O voltage 60 sec 1000, 6000 VDC Tested V1 output/ V2 output 60 sec 1000 VDC Capacitance V input/V output 500VDC 60 pF Capacitance V1 output/V2 output 500VDC 60 pF Resistance 500Vdc >1000 MOhm Output Specifications Parameters Conditions Typical Maximum Units Voltage accuracy See Tolerance Graph ±5 % Short Circuit protection 1000VDC Momentary 1 sec 6000VDC Continuous Short Circuit Restart Auto-Recovery Line voltage regulation For a 1% change of Vin ±1.2 % Load voltage regulation (5 Vout) From 10% load to 100% load 12.8 % Load voltage regulation (9 Vout) 8.3 Load voltage regulation (12 Vout) 6.8 Load voltage regulation (15 Vout) 6.3 Temperature coefficient At 100% load ±0.03 %/oC Ripple & Noise* 20MHz Bandwidth 150 mV p-p Minimum Load Current** 10 % of Max * Test ripple & noise by “Parallel Cable Method” as described in Application Note “Ripple and Noise Measurement of Brick & POL DC-DC Converters” available on Aimtec’s website www.aimtec.com ** If the operating output current is less than 10% of maximum it is recommended to install a load resister in parallel with the load to ensure the actual load current meets the minimum load current requirement. General Specifications Parameters Conditions Typical Maximum Units Switching frequency 100% load, nominal input 100 KHz Operating temperature -40 to + 85 oC Storage temperature -55 to + 125 oC Maximum case temperature 100 oC Cooling Free Air Convection Humidity 95 % RH Case material Plastic(UL94-V0) Weight 1000VDC 2.1 g 6000VDC 3.8 MTBF > 1,000, 000 hours (MIL-HDBK -217F, Ground Benign, t=+25ºC) Maximum Soldering Temperature 1.5mm from case for 10 seconds 260 oC Safety Specifications Parameters Agency approvals CE (for 6000VDC isolation models) Standards EN 60601-1-1; EN 60601-1-2
www.aimtec.com Tel: +1 514 620 2722 Toll free: + 1 888 9 AIMTEC (924 6832) F 051e R12.H 3 of 5 North America only Pin Out Specifications 1000VDC 6000VDC NOTE: On dual output models Pin 5 and Pin 10 are connected internally together. Either Pin 5 or Pin 10, or both can be used as the -Vout NC: not connected Dimensions 1000VDC Pin Single 1 - V in
2 No Pin
3 No Pin
4 No Pin
5 No Pin
6 No Pin
11 No Pin
12 No Pin
13 No Pin
14 No Pin
15 No Pin
5 NC -Vout -V1out
8 NC NC NC
9 NC NC +V2out
10 NC -Vout -V2out
12 NC NC NC
13 NC NC NC
14 NC NC NC
A 0.25 (0.01) 1.30 ±0.13 (0.05 ±0.005) MAX 0.25 (0.01) 5.00º angle A 17.78 (0.70) 17.78 (0.70) 5.75 (0.23) Top View Front View Side View 6.00 (0.24) 1 7 91014 17.78 (0.70) 1.00 (0.04) 2.54 (0.10) 2.75 (0.11) 6523 13 12 8 12.70 (0.50) 1.27 (0.05) 2.54 (0.10) 2.00 (0.08)
www.aimtec.com Tel: +1 514 620 2722 Toll free: + 1 888 9 AIMTEC (924 6832) F 051e R12.H 4 of 5 North America only Dimensions 6000VDC Typical Load Line Tolerance Envelope Graph Output Current(%) Output Voltage +2.5% -2.5% -7.5% +10% +5% 10% 50% 100%
www.aimtec.com Tel: +1 514 620 2722 Toll free: + 1 888 9 AIMTEC (924 6832) F 051e R12.H 5 of 5 North America only Recommended Filter Circuit If it is required to decrease the input/output ripple an “LC” filter network can be installed on the input and output of the converter (see above). It should be noted that the inductance and the resonant frequency of the “LC” filtering network should differ from the DC/DC converter switching frequency to avoid mutual interference. The capacitance of the output filter capacitor must not exceed the values in the Table below to avoid startup problems and ensure safe and reliable operation. It’s not recommended to connect any external capacitor in the application field when output loading is less than 0.5 watt. External Capacitor Tables Input Capacitor (Cin) Output Capacitor (Cout) Overload Protection The output circuit of these products has no protection against overload. It is recommended to install external overload protection in the form of a self-recovery fuse or a circuit breaker in series at the converter’s input. To achieve a high degree of output voltage regulation, over-voltage, and over-current protection it is suggested to use the AM2LV-NZ series as an alternative. NOTE: 1. Datasheets are updated as needed and as such, specifications are subject to change without notice. Once printed or downloaded, datasheets are no longer controlled by Aimtec; refer to www.aimtec.com for the most current product specifications. 2. Product labels shown, including safety agency certifications on labels, may vary based on the date manufactured. 3. Mechanical drawings and specifications are for reference only. 4. All specifications are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at rated output load unless otherwise specified. 5. Aimtec may not have conducted destructive testing or chemical analysis on all internal components and chemicals at the time of publishing this document. CAS numbers and other limited information are considered proprietary and may not be available for release. 6. This product is not designed for use in critical life support systems, equipment used in hazardous environments, nuclear control systems or other such applications which necessitate Vin (VDC) Cin (uF) 5 4.7 12 2.2 24 1 Single Vout (VDC) Cout (uF) Dual Vout (Vdc) Cout (uF) Dual Separated Vout (Vdc) Cout (uF) 5 10 ±5 4.7 5/5 4.7 9 4.7 ±9 2.2 9/9 2.2 12 2.2 ±12 1 12/12 1 15 1 ±15 0.47 15/15 0.47 DC DC + Vin - Vin +Cin + Cout +Cout +Vout -Vout Common Dual OutputL L L DC DC +Cout +Vout - Vin Single Output + Vin - Vin +Cin L L DC DC + Vin - Vin +Cin + Cout + Cout +V1output -V2 output Dual Separated OutputL L L -V1 output +V2 output