Data SheetAll specifications are subject to change without notice. All sales subject to standard terms and conditions. Ashcroft®, Quick-Select™ and Trust the Shield® are trademarks of Ashcroft Inc. The following non-Ashcroft trademarks are the property of their respective owners: 17-4 PH®, VCR®. For more information, see Ashcroft Brands & Trademarks

FEATURES

Monitor up to 3 parameters at once: pressure, temperature, voltage or current Built in data logging up to 16,000 records SD memory card slot for additional data log storage USB Communication interface IP65/NEMA 4X for all weather functionality Interchangeable pressure module to measure from 0.25 in. H2O up to 10,000 psi ORDERING CODE P/N: Description Version ATE 2ST Ashcroft base unit Standard ATE 2IS Ashcroft base unit Intrinsically safe ATE-2 Handheld Calibrator OPTIONAL APPROVALS Hazardous Location Version (Battery Powered Only): Note: Loop power supply is not included with Intrinsically Safe Units FM Intrinsic Safety CL 1, Div 1, Gr A, B, C, D CSA Intrinsic Safety CL 1, Div 1, Gr A, B, C, D ATEX Ex ia ii c T4 Ga –20°C<Ta<50°C Power Requirements: (4) AA Batteries or via USB power supply or USB universal AC adapter 100-240 Vac, 50/60 Hz included Battery Life: Up to 40 hours battery with 2 modules installed Certification: Traceable calibration certificate provided for base unit and Quick-Select™ sensor modules Agency Approvals: CE/UKCA, FCC (CFR47), UL 61010-1 Dimensions: 8.7˝, (L) X 5.1˝, (W) X 3.8˝, (H) Unit Weight: 2.4 lb (no modules) Case Materials: High Impact PC-ABS Enclosure: IP65/NEMA 4X 05182813 SPECIFICATIONS Sensor Inputs: Two Interchangeable pressure and temperature module bays, banana jack inputs for DC voltage or current monitoring Pressure Modules: Pressure ranges from 0.25 in. H2O up to 10,000 psi Accuracy from ±0.025% to ±0.1% of span Hot Swap capable. LCD Display: 2.5˝ (W) x 1.5˝ (H) displays 3 simultaneous measurements, back light, flip screen capability Electrical Connection: 4 mm banana jacks – 1 set of test leads included Loop Power Supply: 24 Vdc-35 mA maximum (non I.S. only) Available Engineering Units: psi, in. H2O, in. Hg, ft SW, bar, mbar, kPa, MPa, mm Hg, cm H2O, mm H2O, kg/cm2, user programmable Operating Temp. Range: -4 °F to 120 °F (-20 °C to 49 °C) Storage Temperature: -4 °F to 158 °F (-20 °C to 70 °C) Update Rate: 100 ms – 1 module installed 200 ms – 2 modules installed 300 ms – 2 modules installed and external input Resolution: ±0.001% span; 99,999 counts Electrical Measurements: 0-20 mA or 0-30 Vdc Accuracy: Input Volts Accuracy 0/10 Vdc ±0.025% of span 10/30 Vdc ±0.10% of span 0-20 mA ±0.03% of span Warm-Up Time: 5 minutes for rated accuracy Programmable Filtering (Damping): Levels 1 through 16 Temperature Effect Electrical Measurement: ±0.001% of span per °F over compensated range from reference temperature of 70 °F (±3 °F) Serial Interface: USB (Micro-B connector type) Field Calibration: Base Unit and pressure modules may be field-calibrated via keypad commands Data Logging: • Internal storage for up to 64 data logs and up to 16,000 records; transferable to SD card

  • Manual/automatic data logging capability
  • Programmable data intervals (0.1 sec. to 24 hrs.)

Data SheetAll specifications are subject to change without notice. All sales subject to standard terms and conditions. Ashcroft®, Quick-Select™ and Trust the Shield® are trademarks of Ashcroft Inc. The following non-Ashcroft trademarks are the property of their respective owners: 17-4 PH®, VCR®. For more information, see Ashcroft Brands & Trademarks AM2-1 Pressure Module AM2-2 Pressure Module STANDARD FUNCTIONS m Data logging allows the user to save pressure, temperature and or electronic values displayed on the LCD to internal memory. Internal memory can hold up to 64 data log files and a total of up to 16,000 individual records. Manual logging is initiated with a single key press. Automatic data logging can be programmed to collect data at timed intervals between 0.1 second and 24 hours. m SD Memory Card Slot gives the ATE-2 additional data storage capability limited only by the capacity of the SD card installed. Data logs stored on the SD card are saved in .csv format which can be read by most spread- sheet programs. Data can easily be transferred from the ATE-2 to a PC. m Loop Power Supply is a standard feature on non-I.S. units and allows the user to conveniently power the device under test with 24 Vdc up to 35 mA m Percent Error Function can be used when calibrating pressure transducers. Calculations are performed by the ATE-2 eliminating potential for human errors. This function enables the user to program the full scale range and electri- cal output of the transducer under test, and will display the actual pressure and electrical output readings as well as a percentage value comparing the actual output to the theoretical output. m Switch Test Function allows the operator to calibrate and document the pressure switch function. The onboard display will show pressure switch trip point, reset point and will calculate switch deadband. All calculations are performed by the ATE-2 eliminating potential for human errors m Dual Mode Function allows the operator to add or subtract the measured pressure values from two installed Quick-Select™ pressure mod- ules. This allows for measurement of “high-line” or elevated static differen- tial pressures. This feature also offers the ability to add barometric pressure from an absolute pressure module to the measured pressure from a gauge pressure module, giving the user the ability to measure a variety of absolute pressures without using designated modules. ATE-2 Handheld Calibrator m Leak Detect the ATE-2 provides the ability to detect and quantify leaks in terms of pressure decay over time. In the pressure decay over time mode the ATE-2 will monitor the desired pres- sure vessel for the programmed time interval and, at the end of the monitor- ing time period, display the measured change in pressure.

Data SheetAll specifications are subject to change without notice. All sales subject to standard terms and conditions. Ashcroft®, Quick-Select™ and Trust the Shield® are trademarks of Ashcroft Inc. The following non-Ashcroft trademarks are the property of their respective owners: 17-4 PH®, VCR®. For more information, see Ashcroft Brands & Trademarks Low pressure modules ranges from 0.25 in. H2O (IWC) to 200 in. H2O (IWC), accuracy ±0.1% to ±0.06% of span, variable capacitance sensor, for use with clean dry gas media Medium/high pressure modules 5 to 10,000 psi, accuracy ±0.1% to ±0.025% of span, 316 Stainless steel isolated sensor, for use with media compatible with 316 Stainless steel Gauge, absolute, differential and compound ranges available Temperature compensated 20 °F to 120 °F AM2-1 Pressure Module AM2-2 Pressure Module AM2-1, AM2-2 Pressure Modules PRODUCT SPECIFICATIONS: AM2-1 Low Pressure Modules: Pressure Types: Differential and compound Available Ranges: Refer to range table Available Accuracies: ±0.06% of span (0/1-0/200 in. H20) ±0.1% of span Compensated Temperature Range: 20 °F to 120 °F (-7 °C to 49 °C) Temperature Effect: ±0.004% of span per °F over compensated range from reference temperature range of 70 °F (±3 °F) Repeatability: ±0.01% of span (range 0/1 in. H20 or higher) ±0.02% of span (range below 1.0 in. H 20) Sensitivity: ±0.002% of span (typical) Under / Overpressure Capability: -15 to 50 psi Maximum Static (line) Pressure: 100 psi Process Connection: 1⁄8 NPT Female (STD.) Media Compatibility: Clean, dry, non-conductive, non-corrosive gas Agency Approvals: FCC (CFR47), UL61010-1, Not RoHS compliant PRODUCT SPECIFICATIONS: AM2-2 Medium High Pressure Modules: Pressure Types: Gauge, absolute, compound and vacuum Available Ranges: Refer to range table Available Accuracies: ±0.025%, ±0.05% or ±0.1% of span (10,000 psi only offered in psig and ±0.1% accuracy) Compensated Temperature Range: 20 °F to 120 °F (-7 °C to 49 °C) Temperature Effect: Standard: ±0.004% of span per °F over compensated range from reference temperature range of 70 °F (±3 °F) Optional: Enhanced Accuracy Option. No additional error due to ambient temperature from 20 °F to 120 °F Sensitivity: ±0.002% of span (typical), ±0.001 of span (max) Repeatability: ±0.01% of span Overpressure Compatibility: 200% for ranges to ≤ 1,000 psi 150% for ranges > 1,000 psi Process Connection: 1⁄8 NPT Female (STD.) Optional pressure connec- tions, 1⁄8 NPT Female NPT with flush-out port, welded VCR® compatible fitting with standard finish (5,000 psi max) Media Compatibility: Any medium compatible with 316 Stainless steel isolation; 10,000 psi range only available with 17-4 PH® / 316 Stainless steel Optional: Clean to ASME B40-100 Level IV, (Not marked for oxygen service) Agency Approvals: CE/UKCA, FCC (CFR47), UL61010-1

Data SheetAll specifications are subject to change without notice. All sales subject to standard terms and conditions. Ashcroft®, Quick-Select™ and Trust the Shield® are trademarks of Ashcroft Inc. The following non-Ashcroft trademarks are the property of their respective owners: 17-4 PH®, VCR®. For more information, see Ashcroft Brands & Trademarks DIFFERENTIAL PRESSURE RANGES in. H2O mm Hg kPa mbar cm H2O mm H2O 0.5 1 0.5 1 1.5 15 1 2 1 2.5 3 30 2 3 2.5 4 5 50 3 5 4 6 6 60 5 10 6 10 15 150 10 20 10 25 30 300 15 30 25 40 60 600 25 50 40 60 150 1500 50 100 100 200 2000 100 200 250 500 5000 150 300 400 200 ORDERING CODE Example: AM2 1 C A D INH2O/ 100 A Model AM2 - Low pressure module AM2 Sensor Type 1 - Capacitive sensor 1 Accuracy B - ±0.1% Accuracy (STD.) bolded values in range table) Media Compatibility A - Non-Isolated Sensor A Pressure Type C - Compound D - Differential D Pressure Units INH2O INH2O/ MMHG KPA MBAR CMH2O MMH2O Ranges (see range table below) 100 100 Inlet Fitting A - 1⁄8 NPT Female A Bold type indicates “C” accuracy is ±0.07% of full span. Consult factory for additional ranges and units of measure. Ranges available per unit of measure. COMPOUND PRESSURE RANGES (All prefixed by ± sign) in. H2O mm Hg kPa mbar cm H2O mm H2O 0.5 1 0.4 1 1.5 15 1 2 0.6 2.5 3 30 1.5 3 1 4 5 50 2.5 5 1.6 6 6 60 5 10 2.5 10 15 150 7.5 15 6 16 20 200 12.5 20 10 25 30 300 25 50 25 60 60 600 50 75 100 150 1500 75 100 160 200 2000 100 150 250 300 3000 200 AM2-1 Low Pressure Modules

Data SheetAll specifications are subject to change without notice. All sales subject to standard terms and conditions. Ashcroft®, Quick-Select™ and Trust the Shield® are trademarks of Ashcroft Inc. The following non-Ashcroft trademarks are the property of their respective owners: 17-4 PH®, VCR®. For more information, see Ashcroft Brands & Trademarks GAUGE / ABSOLUTE PRESSURE RANGES (*Gauge pressure only) (no absolute) psi in. H2O in Hg kPa mbar cm H2O mm Hg bar/kgcm2 MPa mm H2O *5 *100 *10 *25 *250 *250 250 1 1 *3000 10 150 20 40 *300 *300 500 1.6 1.6 5000 15 250 30 60 400 400 750 2.5 2.5 10000 20 300 50 100 500 500 1000 4 4 30 400 100 160 600 600 1500 6 6 50 500 200 250 1000 1000 3000 10 10 60 800 300 400 1600 1600 5000 16 16 100 1000 500 600 2000 2000 25 25 150 1000 2500 2500 40 40 200 4000 4000 60 50 250 5000 5000 100 300 6000 6000 160 500 10000 10000 250 600 400 1000 500 1500 2000 2500 3000 5000 6000 7500 *10000 Vacuum Ranges 10 20 60 600 600 500 0.6 5000 15 30 100 1000 1000 750 1 Compound Pressure Ranges V15 V400 V30 ±60 V1000 V1000 V750 ±0.6 V10000 V30 V60 V100 V2000 V2000 V1500 V1 V60 V100 V200 V4000 V4000 V3000 V2 V400 V4 ORDERING CODE Example: AM2 2 H I G PSI/ 1500 A Model AM2 - Medium/High pressure module AM2 Sensor Type 2 - Piezoresistive sensor 2 Accuracy B - ±0.1% accuracy (STD.) C - ±0.05% accuracy (STD.) D - ±0.025% accuracy (STD.) F - ±0.1% Enhanced temperature compensation 20 °F to 120 °F G - ±0.05% Enhanced temperature compensation 20 °F to 120 °F H - ±0.025% Enhanced temperature compensation 20 °F to 120 °F H Media Compatibility I - Isolated sensor I W - Clean to ASME B40-100 Level IV Pressure Type G - Gauge G V - Vacuum C - Compound Pressure Units PSI PSI/ INH2O INHG KPA MBAR CMH2O MMHG BAR MPA MMH2O KGCM2 Ranges (see range table below) 1500 1500 Inlet Fitting A - 1⁄8 NPT Internal A B - 1⁄8 NPT Internal with flush port C - G 1⁄8 BSP inlet manifold D - G 1⁄8 BSP inlet w/flush port *Gauge pressure only and 0.1% accuracy only. Ranges available per unit of measure. AM2-2 High Pressure Modules

Data SheetAll specifications are subject to change without notice. All sales subject to standard terms and conditions. Ashcroft®, Quick-Select™ and Trust the Shield® are trademarks of Ashcroft Inc. The following non-Ashcroft trademarks are the property of their respective owners: 17-4 PH®, VCR®. For more information, see Ashcroft Brands & Trademarks Measures temperature with most RTD probes Supports 2, 3 and 4-wire RTDs Displays measurement for Farenheit, Celsius, Kelvin Rankine and ohms Easy configurability to meet application PRODUCT SPECIFICATIONS: Following specification is based on use of 4 wire RTD probe; accuracy does not include contribution from RT AM2-RT1 RTD TEMPERATURE MODULE Used with RTD Probe Type Meaurement Range and Accuracy Resolution* Pt100 (385 & 392) - 200 to 550 °C: ±0.15 °C 0.01 °C or °F Ni 120 - 80 to 260 °C: ±0.1 °C 0.1 °C or °F Cu 10 - 70 to 150 °C: ±0.6 °C 0.1 °C or °F Ohms ±0.01% reading ±0.02 ohms 0.004 ohms AM2-RT2 RTD TEMPERATURE MODULE Pt1000 - 200 to 550 °C: ±0.15 °C 0.01 °C or °F Ohms ±0.01% reading ±0.02 ohm 0.004 ohms * Select from 1, 0.1, 0.01 and 0.001 degrees or ohms. Resolution for a given probe is dependent on the output of the probe. Maximum resolution is 1 part in 100,000 of full scale ohms Select from 1, 0.1, 0.01 and 0.001 degrees or output for the probe. Temperature Error: Better than ±0.0005% of reading per degree Fahrenheit from a reference temperature of 70 F ±3 °F Input Receptacle: TA4F type RTD connector AM2-RT1, AM2-RT2 RTD Temperature Modules HOW TO ORDER RTD PROBES Probes are all 4 wire RTDs with 304 Stainless steel sheath and a TA4F electrical connector for compatibility with AM2-RT1 interface modules. They are provided in DIN Class A accuracy. Part No. Description 840X010-01 Pt100 (385), 0.125 diameter, 12 inch length, handle and 5 foot coiled cable 840X010-02 Pt100 (385), 0.25 diameter, 12 inch length, handle and 5 foot coiled cable 840X010-05 Pt100 (385), 0.125 diameter, 6 inch length, handle and 5 foot coiled cable 840X010-06 Pt100 (385), 0.25 diameter, 6 inch length, handle and 5 foot coiled cable 840X010-11 Pt100 (385), 0.125 diameter, 8 inch length, handle and 5 foot coiled cable 840X010-03 Pt100 (385), 0.125 diameter, 12 inch length, 10 foot straight extension lead with plug (no handle) 840X010-04 Pt100 (385), 0.25 diameter, 12 inch length, 10 foot straight extension lead with plug (no handle) 840X010-07 Pt100 (385), 0.125 diameter, 6 inch length, 10 foot straight extension lead with plug (no handle) 840X010-08 Pt100 (385), 0.25 diameter, 6 inch length, 10 foot straight extension lead with plug (no handle) 828X136-01 TA4F mating connector for use with HM2-RT1 module and user supplied RTD probe

Data SheetAll specifications are subject to change without notice. All sales subject to standard terms and conditions. Ashcroft®, Quick-Select™ and Trust the Shield® are trademarks of Ashcroft Inc. The following non-Ashcroft trademarks are the property of their respective owners: 17-4 PH®, VCR®. For more information, see Ashcroft Brands & Trademarks Allows ATE-2 to measure temperature with a thermocouple Pre-programmed to accept 8 most common thermocouple types Displays measurement for Farenheit, Celsius, Kelvin Rankine and millivolts Reference junctions: automatic internal or manual external PRODUCT SPECIFICATIONS: AM2-TC1 THERMOCOUPLE TEMPERATURE MODULE Unit of Measure (selectable): °C, °F, °K, °R and millivolts Reference Junction (selectable): Automatic Mode: The AM2-TC1 module incorporates an internal resistor/ thermistor based reference junction, which may be selected for use in the temperature readout mode. Manual Mode: An external reference junction may be used in place of the internal junction. External reference junctions may be applied in the temperature or direct millivolt readout modes. Resolution Reading in Temperature Units (selectable): 1, .1 or .01 degrees. “Auto” mode selection that allows the ATE-2 to automatically configure the readout to the highest significant resolution (resolution closest to the tolerance) for the thermocouple type selected. Resolution Reading in Millivolts: .001 millivolts Thermocouple Connection (to interface module): Requires a “miniature thermocouple connector” (Omega type SMP), specifically matched to the thermocouple type to be used. These connectors may be purchased as an accessory using the specified part numbers (see how to order thermocouple connector table). SYSTEM ACCURACY (READING IN TEMPERATURE UNITS): Includes the base unit and AM2-TC1 interface module. (Does not include inaccuracy of the thermocouple device. Consult thermocouple manufacturer or ANSI MC96.1 for thermocouple accuracy specifications. Typical inaccuracies range from ±1 to ±2.2 °C.) Conversion Factors to convert °C specifications to other units of measure: To convert from C to F; F = (1.8 x C) + 32 To convert from C to K: K = C + 273.15 To convert from C to R; R = (1.8 x C) + 427.6 Additional thermocouple information on the following page. AM2-TC1 Thermocouple Temperature Modules HOW TO ORDER THERMOCOUPLE CONNECTOR Part No. Description 828X161-01 Type J Connector 828X161-02 Type K Connector 828X161-03 Type T Connector 828X161-04 Type E Connector 828X161-05 Type R Connector 828X161-06 Type S Connector 828X161-07 Type B Connector 828X161-08 Type N Connector Thermocouple probes to be provided by customer.

Data SheetAll specifications are subject to change without notice. All sales subject to standard terms and conditions. Ashcroft®, Quick-Select™ and Trust the Shield® are trademarks of Ashcroft Inc. The following non-Ashcroft trademarks are the property of their respective owners: 17-4 PH®, VCR®. For more information, see Ashcroft Brands & Trademarks Thermocouple Type Measurement Range (°C) Accuracy @ 25 °C) (Not Including Internal Reference Junction) Accuracy @ 25 °C (Including Internal Reference Junction Expressed as ±°C) Max Additional Error Due to Ambient Temperature Deviation from 25 °C (Expressed as Additional °C Deviation from 25 °C) J -151 to -210 1200 to -150 0.7 0.3 1.1 0.4 0.02 0.01 K -201 to -240 -101 to -200 -999 to -100 1.5 1.0 0.5 2.2 1.5 0.8 0.05 0.03 0.02 T -250 to -201 -200 to -101 -100 to 400 1.5 0.8 0.5 2.2 1.2 0.8 0.05 0.03 0.02 E -250 to -201 -200 to -101 -100 to 400 1.2 0.6 0.3 2.0 1.1 0.6 0.04 0.02 0.01 R & S -50 to 299 300 to 1768 3.4 1.2 3.6 1.3 0.10 0.04 B 100 to 199 200 to 499 500 to 999 1000 to 1820 14.0 5.0 3.0 1.2 14.0 5.0 3.0 1.2 0.44 0.16 0.08 0.04 N -250 to -226 -225 to -101 -100 to 1300 4.3 2.1 1.0 5.7 2.8 1.4 0.14 0.07 0.02 AMBIENT TEMPERATURE EFFECT: To calculate, multiply degrees deviation from 25 °C times the value listed in the far right column of the listed table. Only applied when using the internal reference junction, within the ambient window of 0-50 °C. TO CALCULATE TOTAL SYSTEM/MEASUREMENT ACCURACY: Accuracy = System Accuracy @ 25 °C + System Ambient Temperature Effect + Inaccuracy of Thermocouple Device SYSTEM ACCURACY (BASED ON DIRECT MILLIVOLT READING FROM THERMOCOUPLE): Includes the base unit and AM2-TC1 interface module. (Does not include inaccuracy due to the thermocouple device. Reference junction not applicable to direct millivolt readings.) Input Range of Module Accuracy @ 25 °C Max. Additional Error Due to Ambient Temperature Deviation from 25 °C (Expressed as Additional Millivolt Error Per Each °C Deviation from 25 °C) 10 to 100 mV ±0.01 to 100 mV .001 AM2-TC1 Thermocouple Temperature Modules

Data SheetAll specifications are subject to change without notice. All sales subject to standard terms and conditions. Ashcroft®, Quick-Select™ and Trust the Shield® are trademarks of Ashcroft Inc. The following non-Ashcroft trademarks are the property of their respective owners: 17-4 PH®, VCR®. For more information, see Ashcroft Brands & Trademarks OPTIONS Carrying, Transport and Protective Cases: Contoured: Protective Instrument Case with Shoulder Strap. P/N 864D079-01 Heavy Duty, Watertight Instrument Carrying / Transport Case. P/N ATE2-CASE DIMENSIONS Base Unit Carrying Case TYPICAL ASHCROFT ATE-2 BASE UNIT & AM2 PRESSURE MODULE SHOWN 5.06 3.59 8.56 3.80 8.05 ATE-2

19.3 REF

7.4 REF

15.5 REF