20 Watt | DC-DC Converter

www.aimtec.com Tel: +1 514 620 2722 Toll free: + 1 888 9 AIMTEC (924 6832) F 051e R12.D 1 of 3 North America only FEATURES:  Ultra compact footprint 1”x1”  Adjustable Output Voltage  Wide Input Range 2:1  Operating Temperature -40ºC to +75ºC  1600 VDC Isolation  Over Current and Over Voltage Protection  Remote ON/OFF Function  Efficiency up to 90%  No Minimum Load Required  RoHS Compliant  Soft Start Models: Single output Model Input Voltage (V) Output Voltage (V) Output Current max (A) Isolation (VDC) Max Capacitive Load (uF) Efficiency (%) AM20C-1203SZ 9-18 3.3 4.5 1600 7000 86 AM20C-1205SZ 9-18 5 4 1600 5000 90 AM20C-1212SZ 9-18 12 1.67 1600 850 89 AM20C-1215SZ 9-18 15 1.33 1600 700 89 AM20C-2403SZ 18-36 3.3 4.5 1600 7000 86 AM20C-2405SZ 18-36 5 4 1600 5000 89 AM20C-2412SZ 18-36 12 1.67 1600 850 89 AM20C-2415SZ 18-36 15 1.33 1600 700 89 AM20C-4803SZ 36-75 3.3 4.5 1600 7000 86 AM20C-4805SZ 36-75 5 4 1600 5000 89 AM20C-4812SZ 36-75 12 1.67 1600 850 89 AM20C-4815SZ 36-75 15 1.33 1600 700 90 Models: Dual output Model Input Voltage (V) Output Voltage (V) Output Current max (A) Isolation (VDC) Max Capacitive Load (uF) Efficiency (%) AM20C-1212DZ 9-18 ±12 ±0.833 1600 ±470 89 AM20C-1215DZ 9-18 ±15 ±0.667 1600 ±330 89 AM20C-2412DZ 18-36 ±12 ±0.833 1600 ±470 89 AM20C-2415DZ 18-36 ±15 ±0.667 1600 ±330 89 AM20C-4812DZ 36-75 ±12 ±0.833 1600 ±470 89 AM20C-4815DZ 36-75 ±15 ±0.667 1600 ±330 89 NOTE: All specifications in this datasheet are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at rated output load unless otherwise specified. Input Specifications Parameters Nominal Typical Maximum Units Voltage range 12 9-18 VDC 24 18-36 48 36-75 Filter π Start up time Nominal Vin with constant resistive load 30 ms Absolute Maximum Rating

12 Vin 25

48 Vin 100

Peak Input Voltage time 100 ms On/Off control ON –3 to 12VDC (or open) OFF – 0 to 1.2VDC or short pin 2 to pin 3; OFF idle current – 5mA No load current 60 mA Under voltage lockout 12 Vin ON/OFF 8.6 /7.9 VDC 24 Vin ON/OFF 17.8/16 48 Vin ON/OFF 33.5/30.5 Input reflected ripple current 30 mA p-p

www.aimtec.com Tel: +1 514 620 2722 Toll free: + 1 888 9 AIMTEC (924 6832) F 051e R12.D 2 of 3 North America only Isolation Specifications Parameters Conditions Typical Rated Units Tested I/O voltage 3 sec 1600 VDC Case to Input 3 sec 1600 VDC Case to Output 3 sec 1600 VDC Resistance >1000 MOhm Capacitance 1000 pF Output Specifications Parameters Conditions Typical Maximum Units Voltage accuracy ±1 % Cross Regulation (Dual Output Models) 25% load on one output - 100% load on second load ±5 % Over voltage protection Zener Diode Clamp 120 % Over current protection Full Load 150 % Short Circuit protection Continuous Short circuit restart Auto-Recovery Line voltage regulation HL-LL ±0.5 % Load voltage regulation (Single) 0% to 100% load ±0.5 % Load voltage regulation (Dual) 0% to 100% balanced load ±1 % Temperature coefficient ±0.02 %/oC Ripple & Noise 20MHz Bandwidth 100 mV p-p Voltage adjustment range Trim - Single output models only ±10 % General Specifications Parameters Conditions Typical Maximum Units Switching frequency 100% load 330 KHz Operating temperature With derating above +55°C -40 to +75 oC Storage temperature -40 to +125 oC Maximum case temperature 105 oC Derating 2.33 %/ oC Cooling Free air convection Humidity 95 % RH Case material Nickel-coated copper Weight 18 g MTBF > 560,000 hrs (MIL-HDBK -217F, Ground Benign, t=+25oC) Maximum soldering temperature 1.5mm from case for 10 sec 260 oC Transient recovery time Load step change 75% to 50% to 25% 250 µS Transient recovery deviation Load step change 75% to 50% to 25% ±3 % Safety Specifications Parameters Agency Approval CE Standards EN55022: 2006 + A1:2007, Class A IEC61000-3-2:2006+A2:2009 IEC61000-3-3:2008 EN55024:1998 + A1:2001 + A2:2003 IEC61000-4-2: 2008 IEC61000-4-3:2006+A1: 2007 IEC61000-4-4:2004 IEC61000-4-5:2005 IEC61000-4-6:2008 IEC61000-4-8:2009 NOTE: also designed to meet 60950-1:2001

www.aimtec.com Tel: +1 514 620 2722 Toll free: + 1 888 9 AIMTEC (924 6832) F 051e R12.D 3 of 3 North America only Pin Out Specifications Pin Single Dual 1 + V input + V input 2 - V input - V input

3 On/Off Control On/Off Control

5 Trim Common

2.54 (0.10) 20.32 (0.80) 2.54 (0.10) 25.40 (1.00)9.90 (0.39) Derating NOTE: 1. Datasheets are updated as needed and as such, specifications are subject to change without notice. Once printed or downloaded, datasheets are no longer controlled by Aimtec; refer to www.aimtec.com for the most current product specifications. 2. Product labels shown, including safety agency certifications on labels, may vary based on the date manufactured. 3. Mechanical drawings and specifications are for reference only. 4. All specifications are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at rated output load unless otherwise specified. 5. Aimtec may not have c onducted destructive testing or chemical analysis on all internal components and chemicals at the time of publishing this document. CAS numbers and other limit ed information are considered proprietary and may not be available for release. 6. This product is not designed for use in critical life support systems, equipment used in hazardous environments, nuclear control systems or other such applications which necessitate specific safety and regulatory standards other the ones listed in this datasheet. 7. Warranty is in accordance with Aimtec’s standard Terms of Sale available at www.aimtec.com.