200 Watt | DC-DC Converter

www.aimtec.com Tel: +1 514 620 2722 Toll free: + 1 888 9 AIMTEC (924 6832) F 051e R1 1 of 6 North America only FEATURES:

  • Wide Input Range 4:1 • Meet EN50121-3-2
  • Low no-load Power • Industry Standard: 1/4 Brick
  • Efficiency up to 91% • Operating temperature -40°C to + 85°C
  • 2250VDC I/O Isolation
  • Remote ON/OFF Control
  • Over Current, Over Voltage, Over Temperature & Continuous Short Circuit Protection Models Single output Model Input Voltage (VDC) Input Current No load/Full load (mA) Output Voltage (VDC) Output Current max (A) Max Capacitive load (µF) Efficiency (%) AM200QB-4805SH22-NZ 48 (18-75) 200/4845 5 40 6000 88 AM200QB-4812SH22-NZ 48 (18-75) 200/4845 12 16.7 2000 91 AM200QB-4815SH22-NZ 48 (18-75) 200/4845 15 13.3 2000 89 AM200QB-4824SH22-NZ 48 (18-75) 200/4845 24 8.4 1000 91 AM200QB-4848SH22-NZ 48 (18-75) 200/4845 48 4.2 450 91 *Add suffix “-M” for optional aluminum alloy bottom case NOTE: All specifications in this datasheet are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at rated output load unless otherwise specified. Input Specifications Parameters Nominal Typical Maximum Units Voltage range 48V 18-75 80 VDC Filter π(Pi) Network Absolute Maximum Rating -0.7-90 VDC Peak Input Voltage time 1,000 ms Input reflected ripple current 100 mA p-p Under Voltage Lockout (On/Off) 16 VDC Remote On / OFF Control ON: 3.5 ~ 12Vdc or Open Circuit OFF: 0 ~ 1.2Vdc or Ctrl connected to -Vin Idle current: 2-10mA VDC Isolation Specifications Parameters Conditions Typical Rated Units Tested I/O voltage 60s 2250 VDC Input to Case 60s 1500 VDC Output to Case 60s 500 VDC Resistance >100 MOhm Capacitance 2200 pF Output Specifications Parameters Conditions Typical Maximum Units Voltage accuracy 0%-100% load ±1 ±3 % Over voltage protection Zener Diode Clamp Over load protection 110~150 % of Iout Short Circuit protection Continuous, Auto-recovery Thermal shutdown On Case 105 ºC Line voltage regulation LI-HI, Full load ±0.2 ±0.5 Load voltage regulation 0% to 100% Full Load ±0.5 ±0.75 % Temperature coefficient ±0.03 %/oC Ripple & Noise 20MHz Bandwidth 150 250 mV p-p Transient Response Deviation 25% load step change, 5V Vout ±3 ±7.5 % of Max 25% load step change, Others ±3 ±5 Click on Series name for product info on aimtec.com Picture coming soon

www.aimtec.com Tel: +1 514 620 2722 Toll free: + 1 888 9 AIMTEC (924 6832) F 051e R1 2 of 6 North America only Output Specifications(Continued) Parameters Conditions Typical Maximum Units Transient Recovery 300 500 µsec Voltage adjustment range ±10 % General Specifications Parameters Conditions Typical Maximum Units Switching frequency 250 KHz Operating temperature with derating -40 to +85 oC Storage temperature -55 to +125 oC Maximum case temperature 105 oC Cooling Free Air Convection Humidity 95 % RH Case material Aluminum alloy or non-conductive flame-retardant Black Plastic (UL94V-0 rated) Weight Plastic case Optional aluminum alloy case 103 g Dimensions (L x W x H) Plastic case Optional aluminum alloy case MTBF >500,000 hrs (MIL-HDBK-217 F at +25 oC) Maximum soldering temperature 1.5mm from case for 10 sec 300 oC Environment Approval Parameters Conditions Shock and Vibrations IEC/EN61373 on all models Safety Specifications Parameters Standards EMI - Conducted and radiated emission CISPR32/EN55032, class A with the recommended EMC circuit Electrostatic Discharge Immunity IEC 61000-4-2/EN50121-3-2, Contact ±6KV Air ±8KV, Criteria B RF, Electromagnetic Field Immunity IEC 61000-4-3/EN50121-3-2, 10V/m, Criteria A Surge Immunity Meet EN50121-3-2, Differential mode ±1KV with the recommended EMC circuit RF, Conducted Disturbance Immunity IEC 61000-4-6/EN50121-3-2, 10Vrms, Criteria A Pin Out Specifications Dimensions Pin Single 1 +V Input

2 On/Off Control

4 Vo -

5 Sense -

6 Trim

5 Sense +

6 Vo +

DIV: 2.54 x 2.54 Dimensions: mm (inch) Case Tolerance: ±0.50 (0.02) Pin Tolerance: ± 1.50 (0.06) Pin diameter Tolerance: ±0.10 (0.004) Pin 1, 2, 3, 5, 6 & 7 diameter: 1.00 (0.04) Pin 4 & 8 diameter: 1.50 (0.06) Mounting hole screw torque: max 0.4 N m 40.20 (1.58) 61.80 (2.43) 47.20 (1.86) 26.20 (1.03) BOTTOM VIEW 12.70±1.00 (0.50±0.04) 4.50 (0.18) 50.80 (2.00) 12.48 (0.49) 7.62 (0.30) 2xM3 3.00(0.12) 6XØ1.00 (0.04) Side view 2 x ᴓ 3.50(0.14) 2xᴓ 1.50(0.06) 2 x ᴓ 2.00(0.08) 6 x ᴓ 1.50(0.06)

www.aimtec.com Tel: +1 514 620 2722 Toll free: + 1 888 9 AIMTEC (924 6832) F 051e R1 3 of 6 North America only Dimensions with Optional Aluminum Alloy Case (-M option) DIV: 2.54 x 2.54 Dimensions: mm (inch) Case Tolerance: ±0.50 (0.02) Pin Tolerance: ± 1.50 (0.06) Pin diameter Tolerance: ±0.10 (0.004) Pin 1, 2, 3, 5, 6 & 7 diameter: 1.00 (0.04) Pin 4 & 8 diameter: 1.50 (0.06) Mounting hole screw torque: max 0.4 N m 40.20 (1.58) 61.80 (2.43) 47.20 (1.86) 26.20 (1.03) BOTTOM VIEW 14.60±1.00 (0.58±0.04) 4.50 (0.18) 50.80 (2.00) 7.62 (0.30) 2xM3 3.00(0.12) 6XØ1.00 (0.04) Side view 2xᴓ 1.50(0.06) 12.48 (0.49) 3 2 x ᴓ 3.50(0.14) 2 x ᴓ 2.00(0.08) 6 x ᴓ 1.50(0.06) 50.90 (2.00) 56.00 (2.21) Derating -40 0 40 60 80 100 100 Safe Operating Area Output Power (%) Ambient Temperature º C AM200QB-4805S-NZ -20 Vin = 24V Vin = 48V -40 0 40 60 80 100 100 Safe Operating Area Output Power (%) Ambient Temperature º C AM200QB-4805S-NZ-M (Aluminum Alloy) -20 Vin = 24V Vin = 48V -40 0 40 60 80 100 100 Safe Operating Area Output Power (%) Ambient Temperature º C AM200QB-4815S-NZ -20 Vin = 24V Vin = 48V -40 0 40 60 80 100 100 Safe Operating Area Output Power (%) Ambient Temperature º C AM200QB-4815S-NZ-M (Aluminum Alloy) -20 Vin = 24V Vin = 48V

www.aimtec.com Tel: +1 514 620 2722 Toll free: + 1 888 9 AIMTEC (924 6832) F 051e R1 4 of 6 North America only -40 0 40 60 80 100 100 Safe Operating Area Output Power (%) Ambient Temperature º C AM200QB-4812/24/48S-NZ -20 Vin = 24V Vin = 48V -40 0 40 60 80 100 100 Safe Operating Area Output Power (%) Ambient Temperature º C AM200QB-4812/24/48S-NZ-M (Aluminum Alloy) -20 Vin = 24V Vin = 48V Typical Application Circuits DC DC + Vin - Vin Cin 220 µF Cout +Vout - Vout Single Output + + FUSE Output 5V 12V/15V 24V/48V Cout 470 µF 220 µF 100 µF FUSE 20A, slow type Recommended EMC Circuits DC DC +Vout - Vout CY1 1nF/400VAC + Vin - Vin + Vout 47µF/ 100V - Vout CY2 1nF/400VAC CY4 1nF/400VAC 2.2µF/ 100V LDM 1.5µH/15A + Vin - Vin LCM 1mH/15A 150µF/ 100V 2.2µF/ 100V 2.2µF/ 100V 2.2µF/ 100V 2.2µF/ 100V 2.2µF/ 100V 2.2µF/ 100V CY3 1nF/400VAC

www.aimtec.com Tel: +1 514 620 2722 Toll free: + 1 888 9 AIMTEC (924 6832) F 051e R1 5 of 6 North America only Trimming Output voltage can be externally trimmed by utilizing the methods as shown below Fixed Resistor Variable Potentiometer Leave open if not used. AM150QB-4805SH22-NZ Trim down % 1 2 3 4 5 6 7 8 9 10 Trim up % 1 2 3 4 5 6 7 8 9 10 AM150QB-4812SH22-NZ Trim down % 1 2 3 4 5 6 7 8 9 10 Trim up % 1 2 3 4 5 6 7 8 9 10 AM150QB-4815SH22-NZ Trim down % 1 2 3 4 5 6 7 8 9 10 Trim up % 1 2 3 4 5 6 7 8 9 10

www.aimtec.com Tel: +1 514 620 2722 Toll free: + 1 888 9 AIMTEC (924 6832) F 051e R1 6 of 6 North America only AM150QB-4824SH22-NZ Trim down % 1 2 3 4 5 6 7 8 9 10 Trim up % 1 2 3 4 5 6 7 8 9 10 AM150QB-4848SH22-NZ Trim down % 1 2 3 4 5 6 7 8 9 10 Trim up % 1 2 3 4 5 6 7 8 9 10 NOTE: 1. Datasheets are updated as needed and as such, specifications are subject to change without notice. Once printed or downloaded, datasheets are no longer controlled by Aimtec; refer to www.aimtec.com for the most current product specifications. 2. Product labels shown, including safety agency certifications on labels, may vary based on the date manufactured. 3. Mechanical drawings and specifications are for reference only. 4. All specifications are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at rated output load unless otherwise specified. 5. Aimtec may not have conducted destructive testing or chemical analysis on all internal components and chemicals at the time of publishing this document. CAS numbers and other limited information are considered proprietary and may not be available for release. 6. This product is not designed for use in critical life support systems, equipment used in hazardous environments, nuclear control systems or other such applications which necessitate