request sample, configure part A-Series Hydraulic-Magnetic Circuit Breaker PRODUCT WEBPAGE Typical Applications The A-Series hydraulic-magnetic circuit breakers offer precise operation in a compact size for both general purpose as well as full amp load applications. Visi Rocker® and recessed paddle actuators are ideally suited for clean, front panel designs while the metal toggle configuration is ideal for harsh environments. The A-Series is available as a one to six pole configuration, rated up to 50 amps, 277VAC/80VDC and has a max IC of 7,500 amps. Poles VDC Max Max ICVAC Max 1-6 80 7500A277 Compact and Versatile Design Amps Max ∙ Marine ∙ Telecom ∙ Renewable Energy ∙ Generators ∙ Welders ∙ Military ∙ Industrial Automation ∙ Commercial Food ∙ Medical Equipment
- *Manufacturer reserves the right to change product specification without prior notice. RESISTANCE, IMPEDANCE VALUES from Line to Load Terminals (Values Based on Series Trip Circuit Breaker) AMPERE RATING 1000 100 0.1 0.01 0.01 0.100-5.0 5.1-20.0 20.1-50.0 15% FIGURE 1 S M H O 25% 35% CURRENT (AMPS) TOLERANCE (%) 0.1 1 10 100 0.001 RESISTANCE PER POLE VALUES from Line to Load Terminals (Values Based on Series Trip Circuit Breaker)
60 Hz 1/2 Cycle
50 Hz 1/2 Cycle
5.0 10.0 20.0 Time Delay Curves 42, 44 & 46 (50 Amps Max.) Time Delay Curves 22, 24 & 26 (50 Amps Max.) Time Delay Curves 42, 44 & 46 (50 Amps Max.) Time Delay Curves 22, 24 & 26 (50 Amps Max.) 5.0 10.0 20.0 Time Delay Curves 42, 44 & 46 (50 Amps Max.) Time Delay Curves 22, 24 & 26 (50 Amps Max.) Time Delay Curves 42, 44 & 46 (50 Amps Max.) Time Delay Curves 22, 24 & 26 (50 Amps Max.) Pulse Tolerance Curves CURRENT (AMPS) TOLERANCE (%) 0.10 - 5.0 15 5.1 - 20.0 25 20.1 - 50.0 35 Tech Specs Electrical Maximum Voltage 277VAC 50/60 Hz, 80VDC Current Ratings Standard current coils: 0.100, 40.0, 50.0. Other ratings available - consult ordering scheme. Standard Voltage Coils DC-6V, 12V; AC-120V, Other ratings available, consult ordering scheme. Auxiliary Switch Rating SPDT; 10.1 A - 250VAC, 1.0 A-65VDC/0.5 A - 80 VDC, 0.1A - 125VAC (with gold contacts) Insulation Resistance Minimum: 100 Megohms at 500 VDC Dielectric Strength UL, CSA - 1500V 60 Hz for one minute between all electrically isolated terminals. A-Series rocker circuit breakers comply with the 8mm spacing & 3750V dielectric requirements from hazardous voltage to operator accessible surfaces per EN 60950 and VDE 0805. Resistance, Impedance Values from Line to Load Terminal based on Series Trip Circuit Breaker. Mechanical Endurance 10,000 ON-OFF operations @ 6 per minute; with rated Current & Voltage. Trip Free All A-Series Circuit Breakers will trip on overload, even when the actuator is forcibly held in the ON position. Trip Indication The operating actuator moves positively to the OFF position when an overload causes the circuit breaker to trip. When mid-trip handle is specified, the handle moves to the mid position on electrical trip of the circuit breaker. When mid-trip handle with alarm switch is specified, the handle moves to the mid position & the alarm switch actuates when the circuit breaker is electrically tripped Physical Number of Poles 1 - 6 Poles (handle) and 1-3 poles (rocker) at 30 Amps or less.1 and 2 poles at 31 Amps thru 50 Amps. Internal Circuit Config. Series, (with or without auxiliary switch), Shunt and Relay with current or voltage trip coils, Dual Coil, Switch Only with or without auxiliary switch. Weight Approximately 65 grams/pole. (Approximately 2.32 ounces/pole) Standard Colors Housing - Black; Actuator- See Ordering Scheme. Environmental Designed and tested in accordance with requirements of specification MIL-PRF-55629 & MIL-STD-202 as follows: Shock Withstands 100 Gs, 6ms, sawtooth while carrying rated current per Method 213, Test Condition “I”. Instantaneous and ultra-short curves tested @ 90% of rated current. Vibration Withstands 0.060” excursion from 10-55 Hz, and 10 Gs 55-500 Hz, at rated current per Method 204C, Test Condition A. Instantaneous and ultrashort curves tested at 90% of rated current. Moisture Resistance Method 106D; ten 24-hour cycles days @ +85°C, 85% RH. Salt Spray Method 101, Condition A (90-95% RH @ 5% NaCl Solution, 96 hrs). Thermal Shock Method 107D, Condition A (Five cycles @ -55°C to +25°C to +85°C to +25°C). Operating Temperature -40° C to +85° C
- Electrical Tables Table A: Lists UL Recognized & CSA Accepted configurations and performance capabilities as a Component Supplementary Protector. Notes: 1 Requires branch circuit backup with a UL LISTED Type K5 or RK5 fuse (15A minimum) at no more than 4 times the rating of the protector. 2 Same as note 1, except that backup fuse is limited to 80 A maximum. 3 2 pole protector required (with one pole per power line) for: 125/250 VAC, 1 pole protector required for : 125 VAC, 1Ø Power System. Component Supplementary Protectors Circuit Configuration Voltage Current Rating Short Circuit Capacity (Amps) Application Codes NotesMax Rating Frequency Phase Full Load Amps General Purpose Amps UL / CSA With Backup Fuse Without Backup Fuse UL CSA Series
80 DC ---
--- 31 - 50 --- 7500 TC1, 2, OL0, U1 TC1, 2, OL0, U1 125 50 / 60 1 0.02 - 30 --- --- 3000 TC1, OL1, U2 TC1, OL1, U2 Rocker 125 50 / 60 1 1 - 50 --- --- 2000 TC1, OL1, U2 TC1, OL1, U2 125 50 / 60 1 4 1 - 50 --- --- 1000 TC1, OL1, U2 TC3, OL1, U3 125 / 250 50 / 60 1 3 0.02 - 30 --- --- 3000 TC1, 2, OL1, U2 TC1, 2, OL1, U2 Rocker 125 / 250 50 / 60 1 3 0.02 - 50 --- --- 3000 TC1, 2, OL1, U2 TC1, 2, OL1, U2 Handle 250 50 / 60 0.02 - 30 --- --- 1500 TC1, 2, OL0, U2 TC1, 2, OL0, U2 Single Pole 0.02 - 30 --- --- 3000 TC1, OL1, U2 TC1, OL1, U2 Two Pole 1 4 1 - 50 --- --- 1000 TC1, OL1, U2 TC3, OL1, U3 0.02 - 30 --- 5000 2 --- TC1, 2, OL1, C1 TC1, 2, OL1, C1 31 - 50 --- 2000 1 --- TC1, 2, OL1, C1 TC1, 2, OL1, C1 277 50 / 60 1 0.02 - 30 --- 5000 1 --- TC1, 2, OL1, C1 TC1, 2, OL1, C1 Dual Coil --- 31 - 50 --- 7500 TC1, 2, OL0, U1 TC1, 2, OL0, U1 125 50 / 60 1 0.02 - 30 --- --- 3000 TC1, OL1, U2 TC1, OL1, U2 Rocker 1 - 50 --- --- 2000 TC1, OL1, U2 TC1, OL1, U2 125 50 / 60 1 4 0.02 - 30 --- --- 1000 TC1, OL1, U2 TC3, OL1, U3 125 / 250 50 / 60 1 3 0.02 - 30 --- --- 3000 TC1, 2, OL1, U1 TC1, 2, OL1, U1 Rocker 125 / 250 50 / 60 1 3 0.02 - 50 --- --- 3000 TC1, 2, OL1, U2 TC1, 2, OL1, U2 250 50 / 60 1 0.02 - 30 --- --- 1500 TC1, OL0, U2 TC1, OL0, U2 Single Pole 1 0.02 - 30 --- --- 3000 TC1, OL1, U2 TC1, OL1, U2 Two Pole 1 --- 31 - 50 --- 3000 TC1, 2, OL0, U1 TC1, 2, OL0, U1 1 4 1 - 50 --- --- 1000 TC1, OL1, U2 TC3, OL1, U3 0.02 - 30 --- 5000 2 --- TC1, 2, OL1, C1 TC1, 2, OL1, C1 31 - 50 --- 2000 1 --- TC1, 2, OL1, C1 TC1, 2, OL1, C1 277 50 / 60 1 0.02 - 30 --- 5000 1 --- TC1, 2, OL1, U1 TC1, 2, OL1, U1 Shunt 125 / 250 50 / 60 1 0.02 - 30 --- --- 3000 TC1, 2, OL1, U1 TC1, 2, OL1, U1 250 50 / 60 1 0.02 - 30 --- --- 3000 TC1, 2, OL1, U1 TC1, 2, OL1, U1 3 0.02 - 30 --- 5000 2 --- TC1, 2, OL1, C1 TC1, 2, OL1, C1 277 50 / 60 1 0.02 - 30 --- 5000 1 --- TC1, 2, OL1, C1 TC1, 2, OL1, C1 Relay 125 / 250 50 / 60 1 3 0.02 - 30 --- --- 3000 TC1, 2, OL1, U1 TC1, 2, OL1, U1 250 50 / 60 1 0.02 - 30 --- --- 3000 TC1, 2, OL1, U1 TC1, 2, OL1, U1 3 0.02 - 30 --- 5000 2 --- TC1, 2, OL1, C1 TC1, 2, OL1, C1 277 50 / 60 1 0.02 - 30 --- 5000 1 --- TC1, 2, OL1, C1 TC1, 2, OL1, C1 Switch Only not applicable 250 50 / 60 1 --- 31 - 50 3 0.02 - 50 --- 277 50 / 60 1 0.02 - 30 31 - 50 Tech Specs
- Electrical Tables Table B: Lists UL Recognized, CSA Accepted, VDE & TUV Certified configurations & performance capabilities as a Component Supplementary Protector. Notes: 1 General Purpose Ratings for UL/CSA Only. 2 Requires branch circuit backup with a UL LISTED Type K5 or RK5 fuse (15A minimum) at no more than 4 times the rating of the protector. 3 Same as note 2, except that backup fuse is limited to 80 A maximum. Tech Specs Component Supplementary Protectors Circuit Configuration Voltage Current Rating Short Circuit Capacity (Amps) Application Codes NotesMax Rating Frequency Phase Full Load Amps General Purpose Amps UL / CSA VDE TUV With Backup Fuse Without Backup Fuse (Inc) with Backup Fuse (Icn) without Backup Fuse (Inc) with Backup Fuse (Icn) without Backup Fuse UL CSA Series --- --- 7500 --- --- 5000 3000 TC1, 2, OL1, U1 TC1, 2, OL1, U1 World Market Breaker TUV only
0.10 - 30 3000 1500 3000 1500 TC1, 2, OL1, U1 TC1, 2, OL1, U1 Handle: 1 Pole 31 - 50 31 - 50 TC1, 2, OL0, U1 TC1, 2, OL0, U1 0.10 - 30 --- TC1, 2, OL1, U1 TC1, 2, OL1, U1 Rocker: 1-3 Poles 31 - 32 TC1, 2, OL1, U1 TC1, 2, OL1, U1 Rocker: 2 Pole 31 - 50 31 - 50 TC1, 2, OL0, U1 TC1, 2, OL0, U1 Rocker: 1 Pole 250 50 / 60 0.10 - 30 --- --- 3000 3000 1500 5000 TC1, 2, OL1, U1 TC1, 2, OL1, U1 Rocker: 1-3 Poles 31 - 32 --- 6000 1500 TC1, 2, OL1, U1 TC1, 2, OL1, U1 Rocker: 2 Pole 1 0.10 - 30 TC1, OL1, U2 TC1, OL1, U2 1 4 1 - 50 1000 --- --- TC1, OL1, U2 TC3, OL1, U3 Rocker: 1-3 Poles 0.10 - 30 5000 3 --- 3000 1500 3000 TC1, 2, OL1, C1 TC1, 2, OL1, C1 31 - 50 2000 2 TC1, 2, OL1, C1 TC1, 2, OL1, C1 Dual Coil --- --- 7500 3000 1500 3000 1500 TC1, 2, OL1, U1 TC1, 2, OL1, U1 Rocker: 1-3 Poles 250 50 / 60 0.10 - 30 3000 5000 TC1, 2, OL1, U1 TC1, 2, OL1, U1 0.10 - 30 --- 5000 3 --- 3000 1500 3000 TC1, 2, OL1, C1 TC1, 2, OL1, C1 31 - 50 2000 2 --- --- TC1, 2, OL1, C1 TC1, 2, OL1, C1 Shunt 0.10 - 30 --- --- 7500 3000 1500 3000 1500 TC1, 2, OL1, U1 TC1, 2, OL1, U1 Handle: 1 Pole TC1, 2, OL1, U1 TC1, 2, OL1, U1 Rocker: 1-3 Poles 250 50 / 60 1 3000 5000 TC1, 2, OL1, U1 TC1, 2, OL1, U1 0.10 - 30 --- 5000 3 --- 3000 1500 3000 TC1, 2, OL1, C1 TC1, 2, OL1, C1 31 - 50 2000 2 --- --- TC1, 2, OL1, C1 TC1, 2, OL1, C1
- Electrical Tables Time Delay Specs Table C: Lists UL Recognized, CSA Accepted configurations and performance capabilities as Protectors, Supplementary for Marine Electrical and Fuel Systems (Guide PEQZ2, File E75596). Ignition Protected per UL 1500. UL Classified Small Craft Electrical Devices, Marine in accordance with ISO 8846 (Guide UZMK, File MQ1515) as Marine Supplementary Protectors. Table D: Lists UL Listed configurations and performance capabilities as Circuit Breakers for use in Communications Equipment
1 Notes:
2 Available with special catalog number only (consult factory). 3 2 pole protector required (with one per power line) for 125 / 250 VAC. 1 pole protector required for 125 VAC 1 phase power system To view all hydraulic-magnetic circuit breaker time delay values, please visit www.carlingtech.com/sites/default/files/documents/Carling-HM-CB-Time-Delays.pdf Notes:
1 Parallel Pole Construction
UL 1077 Component Recognition Program as Protectors Supplementary (Guide CCN/QVNU2, File E75596) UL 508 Switches, Industrial Control (Guide CCN/NRNT2, File E148683) UL 1500 Protectors, Supplementary for Marine Electrical & Fuel Systems (Guide PEQZ2, File E75596) Ignition Protection UL 489A Communications Equipment (Guide CCN/DITT, File E189195) CSA Certified Component Supplementary Protector under Class 3215 30, File 047848 0 000 CSA Standard C22.2 No. 235 TUV Certified EN60934, under License No. R72103448 VDE Certified EN60934, VDE 0642 under File No. 10537 UL1500 (Marine Ignition Protection) Circuit Configuration Voltage Current Rating Short Circuit Capacity (Amps) Application Codes Max Rating Frequency Phase Full Load Amps Without Backup Fuse UL CSA Series 14 1 DC --- 0.02 - 50 5000 TC1, OL1, U1 TC1, OL1, U1 32 1 TC1, OL1, U2 TC1, OL1, U2 3000 TC1, OL1, U1 TC1, OL1, U1 125
1 TC1, OL1, U2 TC1, OL1, U2
125 / 250 1 2 TC1, OL1, U2 TC1, OL1, U2 250 1 0.02 - 30 1500 TC1, OL1, U1 TC1, OL1, U1 UL489A (Communications Equipment) Circuit Configuration Voltage Current Rating Interrupting Capacity (Amps) Max Rating Frequency General Purpose Amps without Backup Fuse Series 80 DC 0.10 - 50 5000 60 - 90 1
06.
1 One
2 Two
3 Three
4 Four
5 Five
6 Six
03 DC 50/60Hz, Switch Only
10 DC Instantaneous
11 DC Ultra Short
12 DC Short
14 DC Medium
16 DC Long
30 DC, 50/60Hz Instantaneous
31 DC, 50/60Hz Ultra Short
32 DC, 50/60Hz Short
34 DC, 50/60Hz Medium
36 DC, 50/60Hz Long
42 7 50/60Hz Short, High-inrush 44 7 50/60Hz Medium, High-inrush 46 7 50/60Hz Long, High-inrush 52 7 DC, Short, High-inrush 54 7 DC, Medium, High-inrush 56 7 DC, Long, High-inrush Sample Part Number A A 3 - B 0 - 10 -450 - 1 B 1 - C Selection 1 2 3 4 5 6 7 8 9 10 11 Ordering Scheme A Handle, one per pole B Handle, one per multipole unit S Mid-Trip Handle, one per pole T Mid-Trip Handle, one per pole & Alarm Switch A 2. ACTUATOR 1. SERIES A 2 Switch Only (No Coil) F 3 Relay Trip (Current) B Series Trip (Current) G 3 Relay Trip (Voltage) C Series Trip (Voltage) H 3,4 Dual Coil with Shunt Trip D 3 Shunt Trip (Current) Voltage Coil E 3 Shunt Trip (Voltage) K 3,4 Dual Coil with Relay Trip Voltage Coil (Gold Contacts) Notes:
1 Actuator Code:
A: Handle tie pin spacer(s) and retainers provided un-assembled with multi-pole units. B: Handle location as viewed from front of breaker: 2 pole - left pole 3 pole - center pole 4 pole - two handles at center poles 5 pole - three handles at center poles 6 pole - four handles at center poles S: Handle moves to mid-position only upon electrical trip of the breaker. Available with circuit codes B, C, D, E, F, G, H and K. T: Handle moves to mid-position and alarm switch activates only upon electrical trip of the breaker. Available with circuit codes B & C.
2 Switch Only circuits, rated up to 50 amps and 6 poles, and only available when
tied to a protected pole (Circuit Code B, C, D or H.), For .02 to 30 amps, select Cur rent Code 630. For 35 - 50 amps, select Current Code 650. 3 Available with terminal Codes 1, 2 and 3. Current Rating limited to 50A amps maximum.
4 Consult factory for available Dual Coil options, as special catalog number is
required. With Shunt construction, Dual Coils will trip instantaneously on line volt age. Dual coils require 30VA minimum power to trip and are rated for intermittent duty only.
5 Auxiliary Switch breakers with Series Trip & Switch Only circuits: ≤ 30A - supplied
with standard half shells. 35-50A - supplied with extended boat (B-Style) half shells. On multi-pole breakers, one auxiliary switch is supplied, mounted in the extreme right pole. 6 Separate pole type voltage coils not rated for continuous duty. Available only with delay codes 10 and 20. 7 Available with Circuit Codes B & D only. VDE Certified to 30 amps. UL Recognized, CSA Accepted & TUV Certified to 50 amps. 8 VDE Certification available with single pole breakers with DC Delay only. UL Recog nition and CSA Accepted available in one and two pole breakers. 9 Screw Terminals are recommended on ratings greater than 20 amps. Ratings over 30 amps are only available with Terminal Codes 5, 9, G, H, M and Q.
10 Terminal Code 1: VDE Certification up to 25 amps and UL Recognition and CSA
Certification up to 30 amps, but not recommended over 20 amps.
11 Terminal Codes 3, 5, E and H (Bus Type) with VDE, are supplied with Lock Washers,
and Terminal Code M (M6 Threaded Stud) with VDE is supplied with Lock and Flat Washers. These breakers are only VDE Certified when the washers are used. 12 Terminal Code L: VDE Certified available up to 12A. UL Recognized & CSA Accepted available up to 30A.
13 Single pole breakers with Terminal Code P (Printed Circuit Board) are available
up to 30 amps with VDE Certification and 50 amps with UL Recognition and CSA Accepted, with Circuit Codes A, B and C. Two pole breakers with Terminal Code P (Printed Circuit Board) are available up to 40 amps with UL Recognition and CSA Accepted with Circuit Codes A, B and C. 14 Terminal Code Q not available with VDE certification. 15 Single pole only. 3. POLES 4. CIRCUIT 5. AUXILIARY / ALARM SWITCH 6. FREQUENCY & DELAY Actuator Color I-O ON-OFF Dual Legend White A B 1 Black Black C D 2 White Red F G 3 White Green H J 4 White Blue K L 5 White Yellow M N 6 Black Gray P Q 7 Black Orange R S 8 Black Black (short handle)15 T U 9 White MOUNTING STYLE BARRIERS Threaded Insert, 2 per pole 1 6-32 x 0.195 inches no A 6-32 x 0.195 inches yes
2 ISO M3 x 5mm no
B ISO M3 x 5mm (multipole only) yes Front panel Snap-In, 0.75” wide bezel 5 without Handleguard no 6 without Handleguard (multipole only) yes Front panel Snap-In, 0.96” wide bezel 7 without Handleguard, 1-pole 0.96” wide; no multipole units have .105” bezel overhang on all sides 8 without Handleguard, 1-pole 0.96” wide; yes (multipole only) .105” bezel overhang on all sides C UL Recognized & CSA Accepted D VDE Certified, UL Recognized & CSA Accepted E TUV Certified, UL Recognized & CSA Accepted I UL Recognized STD 1077, UL Recognized 1500 (ignition protected), & CSA Accepted 7. CURRENT RATING (AMPERES) 8. TERMINAL 9. ACTUATOR COLOR & LEGEND 10. MOUNTING / BARRIERS 11. AGENCY APPROVAL CODE AMPERES OR VOLTAGE COIL (NORMAL RATED VOLTAGE) 6 020 0.020 025 0.025 030 0.030 035 0.035 040 0.040 045 0.045 050 0.050 055 0.055 060 0.060 065 0.065 070 0.070 075 0.075 080 0.080 085 0.085 090 0.090 095 0.095 210 0.100 215 0.150 220 0.200 225 0.250 230 0.300 235 0.350 240 0.400 245 0.450 250 0.500 255 0.550 260 0.600 265 0.650 270 0.700 275 0.750 280 0.800 285 0.850 290 0.900 295 0.950 410 1.000 512 1.250 415 1.500 517 1.750 420 2.000 522 2.250 527 2.750 430 3.000 435 3.500 440 4.000 445 4.500 450 5.000 455 5.500 460 6.000 465 6.500 470 7.000 475 7.500 480 8.000 485 8.500 490 9.000 495 9.500 610 10.000 710 10.500 611 11.000 711 11.500 612 12.000 712 12.500 613 13.000 614 14.000 615 15.000 616 16.000 617 17.000 618 18.000 620 20.000 622 22.000 624 24.000 625 25.000 630 30.000 635 8 35.000 640 8 40.000 645 8 45.000 650 8 50.000 A06 6 DC A12 12 DC A18 18 DC A24 24 DC A32 32 DC A48 48 DC A65 65 DC J06 6 AC J12 12 AC J18 18 AC J24 24 AC J48 48 AC J65 65 AC K20 120 AC L40 240 AC 1 10 Push-On 0.250 Tab (Q.C.)
2 Screw 8-32 with upturned
3 11 Screw 8-32 (Bus Type)
4 Screw 10-32 with upturned
5 11 Screw 10-32 (Bus Type)
6 Screw 8-32 with upturned
lugs & 30° bend
7 Screw 8-32 (Bus Type)
& 30° bend
8 Screw 10-32 with upturned
lugs & 30° bend
9 Screw 10-32 (Bus Type)
& 30° bend B Screw M5 with upturned lugs C Screw, M4 with upturned lugs E 11 Screw M4 (Bus Type) F Screw M5 with upturned lugs & 30° bend G Screw M5 (Bus Type) & 30° bend H 11 Screw M5 (Bus Type) L 12 0.250 Q.C./ Solder Lug M 11 M6 Threaded Stud P 13 Printed Circuit Board Terminals Q 14 Push-In Stud R Screw, M4 with upturned lugs & 30° Bend S 13 Push-On 0.110 Tab (Q.C.) T 11 Screw, M4 with upturned lugs Handle - UL 1077 Recognized Configure Complete Part Number > Browse Standard Parts >
07. B Series Trip (Current) Notes: A: Handle tie pin spacer(s) and retainers provided un-assembled with multi-pole units. S: Handle moves to mid-position only upon electrical trip of the breaker. T: Handle moves to mid-position and alarm switch activates only upon electrical trip of the breaker.
2 On multi-pole breakers, one auxiliary switch is supplied, mounted in the extreme right
pole. 3 VDE Certified to 30 amps. UL489A Listed to 50 amps. 4 VDE Certification available with single pole breakers only. UL489A Listing available with one and two pole breakers. 5 Screw Terminals are recommended on ratings greater than 20 amps. Ratings over 30 amps are only available with Terminal Codes 5, 9 G, H, M and Q.
6 Terminal Code 1 (Push-On) available up to 25 amps with VDE Certification and 30
amps with UL489A Listing, but is not recommended over 20 amps.
7 Terminal Codes 3, 5 and H (Bus Type) with VDE, are supplied with Lock Washers, and
Terminal Code M (M6 Threaded Stud) with VDE is supplied with Lock and Flat Washers. These breakers are only VDE Certified when the washers are used.
8 Single pole breakers with Terminal Code P (Printed Circuit Board) are available up to
30 amps with VDE Certification and 50 amps with UL489A Listing. 9 Terminal Code Q not available with VDE certification. 10 Single pole only. Actuator Color ON-OFF Dual Legend Color White B 1 Black Black D 2 White Red G 3 White Green J 4 White Blue L 5 White Yellow N 6 Black Gray Q 7 Black Orange S 8 Black Black (short handle) 10 U 9 White Sample Part Number A A 1 - B 0 - 14 -450 - 1 B 1 - M T Selection 1 2 3 4 5 6 7 8 9 10 11 12 Ordering Scheme A Handle, one per pole S Mid-Trip Handle, one per pole T Mid-Trip Handle, one per pole & Alarm Switch (Gold Contacts) A 2. ACTUATOR
5 AUXILIARY/ALARM SWITCH
- SERIES 3. POLES 4. CIRCUIT 7. CURRENT RATING (AMPERES) 8. TERMINAL MOUNTING STYLE BARRIERS Threaded Insert, 2 per pole 1 6-32 x 0.195 inches no A 6-32 x 0.195 inches yes
B ISO M3 x 5mm (multipole only) yes Front panel Snap-In, 0.75” wide bezel 5 without Handleguard no 6 without Handleguard (multipole only) yes Front panel Snap-In, 0.96” wide bezel 7 without Handleguard, 1-pole 0.96” wide; no multipole units have .105” bezel overhang on all sides 8 without Handleguard, 1-pole 0.96” wide; yes (multipole only) .105” bezel overhang on all sides M 80 DC T UL489A Listed K UL489A Listed, VDE Certified J UL489A Listed, TUV Certified 9. ACTUATOR COLOR & LEGEND 10. MOUNTING / BARRIERS 11. MAXIMUM APPLICATION RATING 12. AGENCY APPROVAL CODE AMPERES 210 0.100 215 0.150 220 0.200 225 0.250 230 0.300 235 0.350 240 0.400 245 0.450 250 0.500 255 0.550 260 0.600 265 0.650 270 0.700 275 0.750 280 0.800 285 0.850 290 0.900 295 0.950 410 1.000 512 1.250 415 1.500 517 1.750 420 2.000 522 2.250 527 2.750 430 3.000 435 3.500 440 4.000 445 4.500 450 5.000 455 5.500 460 6.000 465 6.500 470 7.000 475 7.500 480 8.000 485 8.500 490 9.000 495 9.500 610 10.000 710 10.500 611 11.000 711 11.500 612 12.000 712 12.500 613 13.000 614 14.000 615 15.000 616 16.000 617 17.000 618 18.000 620 20.000 622 22.000 624 24.000 625 25.000 630 30.000 635 3 35.000 640 3 40.000 645 3 45.000 650 3 50.000 1 6 Push-On 0.250 Tab (Q.C.) 3 7 Screw 8-32 (Bus Type) 5 7 Screw 10-32 (Bus Type) lugs & 30° bend & 30° bend lugs & 30° bend & 30° bend B Screw M5 with upturned lugs F Screw M5 with upturned lugs & 30° bend G Screw M5 (Bus Type) & 30° bend H Screw M5 (Bus Type) M 7 M6 Threaded Stud P 8 Printed Circuit Board Terminals Q 9 Push-In Stud & 30° bend Handle - UL 489A Listed Configure Complete Part Number > Browse Standard Parts > 52 3 DC, Short, High-inrush 54 3 DC, Medium, High-inrush 56 3 DC, Long, High-inrush 6. FREQUENCY & DELAY
- A-Series Circuit Breaker - Handle WORLD – Ordering Scheme
42 7 50/60Hz Short, High-inrush 44 7 50/60Hz Medium, High-inrush 46 7 50/60Hz Long, High-inrush 52 7 DC, Short, High-inrush 54 7 DC, Medium, High-inrush 56 7 DC, Long, High-inrush Notes: A: Handle tie pin spacer(s) and retainers provided unassembled with multi-pole units. S: Handle moves to mid-position only upon electrical trip of the breaker. Available with circuit codes B, C, D, E, and H. T: Handle moves to mid-position and alarm switch activates only upon electrical trip of the breaker. Available with circuit codes B & C. tied to a protected pole (Circuit Code B, C, D or H.), For .01 to 30 amps, select Current Code 630. For 35 - 50 amps, select Current Code 650. 3 Available with terminal Codes 1, 2 and 3. Current Rating limited to 30 amps maximum. required. With Shunt construction, Dual Coils will trip instantaneously on line volt age. Dual coils require 30VA minimum power to trip and are rated for intermittent duty only.
5 On multi-pole breakers, one auxiliary switch is supplied, mounted in the extreme
right pole. 6 Separate pole type voltage coils not rated for continuous duty. Available only with delay codes 10, 20 & 30. 7 Available with Circuit Codes B & D only. VDE Certified to 30 amps. UL Recognized, CSA Accepted & TUV Certified to 50 amps. 8 Available up to two poles with AC or DC delays. 9 Screw Terminals are recommended on ratings greater than 20 amps. Ratings over 30 amps are only available with Terminal Codes 5, 9, G and H.
10 Terminal Code 1: TUV Certification up to 30 amps, but not recommended over 20
amps. 11 Terminal Codes 3, 5 , 7, 9, E, G and H (Bus Type) are supplied with Lock Washers. These breakers are only TUV Certified when the washers are used. 12 Single pole only. Actuator Color I-O Dual Legend Color White A 1 Black Black C 2 White Red F 3 White Green H 4 White Blue K 5 White Yellow M 6 Black Gray P 7 Black Orange R 8 Black Black (short handle)15 T 9 White Sample Part Number A A 3 - B 0 - 14 -450 - 1 A 1 - P Selection 1 2 3 4 5 6 7 8 9 10 11 Ordering Scheme A Handle, one per pole B Handle, one per multipole unit S Mid-Trip Handle, one per pole T Mid-Trip Handle, one per pole & Alarm Switch A 2 Switch Only (No Coil) D 3 Shunt Trip (Current) B Series Trip (Current) E 3 Shunt Trip (Voltage) C Series Trip (Voltage) H 3,4 Dual Coil with Shunt Trip Voltage Coil 0 without Aux Switch A 2. ACTUATOR 1. SERIES 3. POLES 4. CIRCUIT 5. AUXILIARY / ALARM SWITCH 6. FREQUENCY & DELAY 7. CURRENT RATING (AMPERES) 8. TERMINAL MOUNTING STYLE BARRIERS Threaded Insert, 2 per pole 1 6-32 x 0.195 inches no A 6-32 x 0.195 inches yes B ISO M3 x 5mm (multipole only) yes Front panel Snap-In, 0.75” wide bezel 5 without Handleguard no 6 without Handleguard (multipole only) yes Front panel Snap-In, 0.96” wide bezel 7 without Handleguard, 1-pole 0.96” wide; no multipole units have .105” bezel overhang on all sides 8 without Handleguard, 1-pole 0.96” wide; yes (multipole only) .105” bezel overhang on all sides P TUV Certified, UL Recognized & CSA Accepted Q UL Recognized STD 1077, UL Recognized 1500 (ignition protected), & CSA Accepted
9 ACTUATOR COLOR & LEGEND
- MOUNTING / BARRIERS 11. AGENCY APPROVAL CODE AMPERES OR VOLTAGE COIL (NORMAL RATED VOLTAGE) 6 210 0.100 215 0.150 220 0.200 225 0.250 230 0.300 235 0.350 240 0.400 245 0.450 250 0.500 255 0.550 260 0.600 265 0.650 270 0.700 275 0.750 280 0.800 285 0.850 290 0.900 295 0.950 410 1.000 512 1.250 415 1.500 517 1.750 420 2.000 522 2.250 527 2.750 430 3.000 435 3.500 440 4.000 445 4.500 450 5.000 455 5.500 460 6.000 465 6.500 470 7.000 475 7.500 480 8.000 485 8.500 490 9.000 495 9.500 610 10.000 710 10.500 611 11.000 711 11.500 612 12.000 712 12.500 613 13.000 614 14.000 615 15.000 616 16.000 617 17.000 618 18.000 620 20.000 622 22.000 624 24.000 625 25.000 630 30.000 635 8 35.000 640 8 40.000 645 8 45.000 650 8 50.000 A06 6 DC A12 12 DC A18 18 DC A24 24 DC A32 32 DC A48 48 DC A65 65 DC J06 6 AC J12 12 AC J18 18 AC J24 24 AC J48 48 AC J65 65 AC K20 120 AC L40 240 AC 1 10 Push-On 0.250 Tab (Q.C.)
3 11 Screw 8-32 (Bus Type) 5 11 Screw 10-32 (Bus Type) lugs & 30° bend & 30° bend lugs & 30° bend & 30° bend B Screw M5 with upturned lugs C Screw, M4 with upturned lugs E 11 Screw M4 (Bus Type) F Screw M5 with upturned lugs & 30° bend G Screw M5 (Bus Type) & 30° bend H 11 Screw M5 (Bus Type) M M6 Threaded Stud R Screw, M4 with upturned lugs & 30° Bend T 11 Screw, M4 with upturned lugs Handle - World Configure Complete Part Number > Browse Standard Parts >
- AUXILIARY/ALARM SWITCH TERMINAL DETAIL > 30 AMPS < 30 AMPS LOAD LOAD TAB (Q.C.) TAB (Q.C.) LINE LOAD K 0 FG 0 VOLTAGE COIL LINE LOAD LINE LOAD SHUNT LINE CIRCUIT SCHEMATIC ANSI SERIES TRIP CIRCUIT SCHEMATICCIRCUIT BREAKER PROFILE ANSI SWITCH ONLY (NO COIL) CIRCUIT CODE AUX SWITCH CODE CIRCUIT CODE AUX SWITCH CODE LOAD LINE LOAD LINE LOAD LINE LOAD H BC NC C NO NC C NO NC C NO NC C ALARM SWITCHSTANDARD AUX. SWITCH NO 0DE 0 BC 0 BCA A VOLTAGE COIL SHUNT TRIP LINE LOAD RELAY RELAY RELAY TRIP4 TERMINALS DUAL COIL; SERIES TRIP CURRENT COIL, RELAY TRIP VOLTAGE COIL DUAL COIL; SERIES TRIP CURRENT COIL, RELAY TRIP VOLTAGE COIL SERIES TRIP WITH (3) AUXILIARY/ALARM SWITCH TAB (Q.C.) NC NO C NC NO C LINE LOAD LINE .520 [13.21] .205 [5.21] .390 [9.91]
3 TERMINALS
.390 [9.91]
5 TERMINALS
2 TERMINALS
AUX. SWITCH TERMINALS MAIN TERMINALS (SEE TABLE A) ALARM SWITCH TERMINALS & STD. AUX. VDE OR <30 AMPS oR AGENCY CODE”P” .205 [5.21] 1.640 [41.66] .520 [13.21] .780 [19.81] .406 [10.31] .344 [8.74] .250 [6.35] .093 [2.36] .110 [2.79] .677 [17.19] .239 [6.07] .051 DIA [ 1.29] .050 DIA [ 1.27]
2 PLCS
1.000 [25.40] .110 [2.80] .087 [2.20] .287 [7.29] NC NO C Notes: 1 Tolerance ±.020 [.51] unless otherwise specified. Circuit & Terminal Diagrams inches [millimeters] Handle
- HANDLE POSITION VS. AUX/ALARM SWITCH MODE TERMINAL DIMENSIONAL DETAIL & RATING TABLE A TIGHTENING TORQUE SPECIFICATIONS TABLE B STANDARD C/B CIRCUIT BREAKER MODE ELECTRICAL TRIP TAB(Q.C.)
30 AMP
#8-32 30 AMP #10-32 30 AMP #8-32 30 AMP QC SOLDER LUG .110 QC VOLTAGE COILS ONLY M6 STUD
50 AMP
50 AMP#10-32 50 AMP
HANDLE POSITIONHANDLE POSITIONHANDLE POSITION AUX. SWITCH MODE ALARM SWITCH MODE AUX. SWITH CODE (W/O ALARM SWITCH) .360 [9.14] .250 [6.35] .392 [9.96] .375 [9.53] .392 [9.96] .375 [9.53] .344 [8.74] .250 [6.35] .520 [13.21] 2.000 [50.80] 1.560 [39.62] .361 [9.17] .110 [2.79] .750 [19.05] .405 [10.29] .100 [2.54] .750 [19.05] .093 [.76] .069 [1.75] DIA DIA .154 [3.91]DIA 1.000 [25.40] .392 [9.97] CENTERLINE OF PUSH-IN STUD CONTACT AREA TORQUETHREAD SIZE 7-9 IN-LBS [0.8-1.0 NM] #6-32 & M3 MOUNTING HARDWARE PUSH-IN STUD MATING HOLE BARRIER FOR UL-RECOGNIZED MULTI-POLE BREAKERS SEE TABLE-B DEPTH BEHIND PANEL 12-15 IN-LBS [1.4-1.7 NM] #8-32 & M4 THREAD TERMINAL SCREW 15-20 IN-LBS [1.7-2.3 NM] #10-32 & M5 THREAD TERMINAL SCREW 2.000[50.80] 2.207[56.10] 2.364[60.05] TAB (Q.C.) TAB (Q.C.) 1.970[50.00]SOLDER TYPE MAIN TERMINAL DESCRIPTION DEPTH BEHIND PANEL SHUNT,RELAY DUAL COIL AUX. SWITCH* SCREW #8-32 W/UPTURNED LUGS 2.032[51.60]SCREW TYPE .161 DIA [ 4.10] +.002 -.000 [+.05] [-.00] LINE LOAD LINE (NETZ) (LAST) LOAD M6 STUD PUSH-IN STUD SCREW TERMINAL WITH 30 BEND *AVAILABLE ON SERIES TRIP AND SWITCH ONLY CIRCUITS WHEN CALLED FOR ON MULTI-POLE UNITS, ONLY ONE AUX. SWITCH IS NORMALLY SUPPLIED, AS SHOWN IN MULTI-POLE INDENTIFICATION SHEME. 1.640 [41.66] REF .032 [.81]TYP ON OFF O MID TRIP .220 [5.59] 1.936 [49.17] TYP .393 [9.96]REF 1.350 [34.29] 1.560 [39.62]TYP Notes: 1 Tolerance ±.020 [.51] unless otherwise specified. 2 Alarm Switch available with .110 x .020 QC & solder lug terminals only. Circuit & Terminal Diagrams inches [millimeters] Handle
- Notes: 1 Tolerance ± 0.20 [.51] unless otherwise specified. 2 For agency code P = .150 [3.81]. 1-POLE (AA1) 2-POLE (AA2) 3-POLE (AA3) 4-POLE (AA4) 2-POLE (AB2) 3-POLE (AB3) 4-POLE (AB4) TAB (Q.C.) TYPE TERMINALS IN SERIES TRIP CONCUIT CONFIGURATION SHOWN. FOR OTHER CONFIGURATIONS SEE CIRCUIT & TERMINAL DIAGRAMS LOAD LINE LOAD LINE #6-32 [M3] THREAD X.195[4.95]DEEP
2 PLCS PER POLE TYP
.610 [15.49] .130 [3.30] 1.640 [41.66] TYP 1.560 [39.62] MAX .755 [19.18] .170 [4.32] MAX 1.515 [38.48] MAX 1.515 [38.48] MAX 2.265 [57.53] MAX 3.015 [76.58] TYP .750 [19.05] 1.660 [42.16] PER POLE AA1, AB2, AB3 AA2, AB4 AA3 AA4 TOLERANCE +.005[+.12] UNLESS OTHERWISE SPECIFIED _ _ PANEL CUTOUT DETAIL 1.050 [26.67] .750 [19.05] TYP MAX .750 [19.05] 2.265 [57.53] TYP MAX .750 [19.05] 3.015 [76.05] SHORT HANDLE .250 [6.35] .690 [17.50] 2.000 [50.80] 2.032 [51.61] TAB (Q.C.) TYPE SCREW TYPE TYPICAL-OPTIONAL “ON-OFF” LEGEND MULTI-POLE HANDLE TIE KIT SHIPPED BULK MULTI-POLE INDENTIFICATION SCHEME AS VIEWED FROM TERMINAL END OF BREAKER. POLE
1 POLE
2 POLE
3 POLE
.630 DIA [ 16.00] +.010 -.000 [+.25]
2 PLCS TYP
inches [millimeters] Handle
- TAB (Q.C.) TYPE TERMINALS IN SERIES TRIP CIRCUIT CONFIGURATION SHOWN. FOR OTHER CONFIGURATIONS, SEE CIRCUIT AND TERMINAL DIAGRAMS. MAX BREAKER WIDTH .755 [19.18] TYP AA1 AA2, AB2 AA3, AB3 AA4, AB4 .770 [19.56] .010 [.25] 2.187 [55.55] .012 [.30] 3.030 [76.96] .010 [.25] 2.280 [57.91] .010 [.25] 1.530 [38.86] .010 [.25] PANEL CUTOUT DETAIL
4 POLE
(AB4) (AB3) (AA4) (AA3) (AA2) (AB2) (AA1) 2.976 [75.59] 2.232 [56.69] 1.488 [37.80] .744 [18.90] TYP 2.598 [65.99] .125 [3.18] .690 [17.50] .250 [6.35] (SHORT HANDLE) OFF ON TYP 1.640 [41.66] TYP 1.560 [39.62] TYP 2.000 [50.80] TYP 1.220 [31.00] LOAD LINE 2.000 [50.80] 2.032 [51.61] SCREW TYPE .250 TAB (Q.C.) TYPE 1.488 [37.80] 2.976 [75.59] 2.323 [56.69] MULTI-POLE HANDLE TIE KITSHIPPED BULK Notes: 2 Tolerance ±.020 [.51] unless otherwise specified. Dimensional Specs inches [millimeters] Handle
- PANEL CUTOUT DETAIL TAB (Q.C.) TYPE TERMINALS IN SERIES TRIP CIRCUIT CONFIGURATION SHOWN. FOR OTHER CONFIGURATIONS, SEE CIRCUIT AND TERMINAL DIAGRAMS. MAX BREAKER WIDTH
(AB4) (AB3) (AA4) (AA3) (AA2) (AB2) OFF ON TYP 1.640 [41.66] TYP 2.598 [65.99] TYP TYP AA1 AA2, AB2 AA3, AB3 AA4, AB4 1.560 [39.62] .770 [19.56] 1.700 [43.18] 3.190 [81.03] 2.450 [62.23] 3.190 [81.03] MULTI-POLE HANDLE TIE KIT SHIPPED BULK 2.450 [62.23] 1.700 [43.18] .960 [24.38] 2.000 [50.80] 2.032 [51.61].690 [17.50] .250 [6.35] (SHORT HANDLE) SCREW TYPE .250 TAB (Q.C.) TYPE .010 [.25] 2.187 [55.55] .012 [.30] 3.030 [76.96] .010 [.25] 2.280 [57.91] .010 [.25] 1.530 [38.86] .010 [.25] .755 [19.18] TYP 2.000 [50.80] TYP 1.220 [31.00] LOAD LINE (AA1) Notes: 2 Tolerance ±.020 [.51] unless otherwise specified. Dimensional Specs inches [millimeters] Handle
- A-Series Circuit Breaker - Sealed Toggle UL Recognized – Ordering SchemeA-Series Circuit Breaker - Handle WORLD – Ordering Scheme
1 One 2 Two 3 Three
42 7 50/60Hz Short, High-inrush 44 7 50/60Hz Medium, High-inrush 46 7 50/60Hz Long, High-inrush 52 7 DC, Short, High-inrush 54 7 DC, Medium, High-inrush 56 7 DC, Long, High-inrush Notes:
1 Actuator Code M: Handle location as viewed from front of panel:
2 pole - right pole 3 pole - center pole 2 Switch Only circuits, rated up to 50 amps and 3 poles. Only available when tied to a protected pole. For .02 to 30 amps, select Current Code 630. For 35 - 50 amps, select Current Code 650. 3 Available with terminal Codes 1, 2 and 3. Current Rating limited to 30 amps maximum. required. With Shunt construction, Dual Coils will trip instantaneously on line volt age. Dual coils require 30VA minimum power to trip and are rated for intermittent duty only. 5 Auxiliary Switch available on Series Trip & Switch Only circuits, limited to 30 amps. On multi-pole breakers, one auxiliary switch is supplied, mounted in the extreme right pole. 6 Voltage coils not rated for continuous duty. Available only with delay codes 10 and 20. 7 Available with Circuit Codes B & D only. VDE Certified to 30 amps. UL Recognized, CSA Accepted & TUV Certified to 50 amps. 8 UL Recognition and CSA Certification available on one and two pole breakers. 9 Screw Terminals are recommended on ratings greater than 20 amps. Ratings over 30 amps are only available with Terminal Codes 5, 9, B, F, G, H, M and Q.
10 Terminal Code 1: UL Recognition and CSA Certification up to 30 amps, but not
recommended over 20 amps. 11 Terminal Code L : available up to 30A.
12 Single pole breakers with Terminal Code P (Printed Circuit Board) are available up
to 50 amps, with Circuit Codes A, B and C. Two pole breakers with Terminal Code P (Printed Circuit Board) are available up to 40 amps with Circuit Codes A, B and C.
0 No legend plate
Part Number A M 1 - B 0 - 10 -450 - 1 0 1 - C Selection 1 2 3 4 5 6 7 8 9 10 11 Ordering Scheme M Sealed Toggle, one per unit A 2 Switch Only (No Coil) F 3 Relay Trip (Current) B Series Trip (Current) G 3 Relay Trip (Voltage) C Series Trip (Voltage) H 3,4 Dual Coil with Shunt Trip D 3 Shunt Trip (Current) Voltage Coil E 3 Shunt Trip (Voltage) K 3,4 Dual Coil with Relay Trip Voltage Coil (Gold Contacts) A 2. ACTUATOR 1. SERIES 3. POLES 4. CIRCUIT 5. AUXILIARY / ALARM SWITCH 6. FREQUENCY & DELAY 7. CURRENT RATING (AMPERES) 8. TERMINAL MOUNTING STYLE BARRIERS
1 Standard Hex Nut no
A Standard Hex Nut (multipole only) yes C UL Recognized & CSA Accepted I UL Recognized STD 1077, UL Recognized 1500 (ignition protected), & CSA Accepted 9. LEGEND PLATE 10. MOUNTING / BARRIERS 11. AGENCY APPROVAL CODE AMPERES OR VOLTAGE COIL (NORMAL RATED VOLTAGE) 6 020 0.020 025 0.025 030 0.030 035 0.035 040 0.040 045 0.045 050 0.050 055 0.055 060 0.060 065 0.065 070 0.070 075 0.075 080 0.080 085 0.085 090 0.090 095 0.095 210 0.100 215 0.150 220 0.200 225 0.250 230 0.300 235 0.350 240 0.400 245 0.450 250 0.500 255 0.550 260 0.600 265 0.650 270 0.700 275 0.750 280 0.800 285 0.850 290 0.900 295 0.950 410 1.000 512 1.250 415 1.500 517 1.750 420 2.000 522 2.250 425 2.500 527 2.750 430 3.000 435 3.500 440 4.000 445 4.500 450 5.000 455 5.500 460 6.000 465 6.500 470 7.000 475 7.500 480 8.000 485 8.500 490 9.000 495 9.500 610 10.000 710 10.500 611 11.000 711 11.500 612 12.000 712 12.500 613 13.000 614 14.000 615 15.000 616 16.000 617 17.000 618 18.000 620 20.000 622 22.000 624 24.000 625 25.000 630 30.000 635 8 35.000 640 8 40.000 645 8 45.000 650 8 50.000 A06 6 DC A12 12 DC A18 18 DC A24 24 DC A32 32 DC A48 48 DC A65 65 DC J06 6 AC J12 12 AC J18 18 AC J24 24 AC J48 48 AC J65 65 AC K20 120 AC L40 240 AC 1 10 Push-On 0.250 Tab (Q.C.)
3 Screw 8-32 (Bus Type)
5 Screw 10-32 (Bus Type)
lugs & 30° bend & 30° bend lugs & 30° bend & 30° bend B Screw M5 with upturned lugs C Screw, M4 with upturned lugs E Screw M4 (Bus Type) F Screw M5 with upturned lugs & 30° bend G Screw M5 (Bus Type) & 30° bend H Screw M5 (Bus Type) L 12 0.250 Q.C./ Solder Lug M M6 Threaded Stud P 12 Printed Circuit Board Terminals Q Push-In Stud R Screw, M4 with upturned lugs & 30° Bend S 17 Push-On 0.110 Tab (Q.C.) & 30° bend T Screw, M4 with upturned lugs Sealed Toggle Configure Complete Part Number > Browse Standard Parts >
- Notes: 1 Tolerance ±.020 [.51] unless otherwise specified. Dimensional Specs inches [millimeters] Sealed Toggle
16. 42 9 50/60Hz Short, High-inrush 44 9 50/60Hz Medium, High-inrush 46 9 50/60Hz Long, High-inrush 52 9 DC, Short, High-inrush 54 9 DC, Medium, High-inrush 56 9 DC, Long, High-inrush Notes: 1 Push-To-Reset actuators have OFF portion of rocker shrouded.
2 Multi-pole breakers have all breakers identical except when specifying Auxiliary switch
and/or mixed poles, and have one rocker per breaker.
3 Switch Only circuits, rated up to 50 amps & 3 poles, are available only when tied to a
protected pole (Circuit Code B, C, D or H.), For .02 to 30 amps, select Current Code 630. For 35 - 50 amps, select Current Code 650. 4 Available with terminal Codes 1, 2 and 3. Current Rating limited to 30 amps maximum. 5 Consult factory for Dual Coil options, as special catalog number is required. With Shunt construction, Dual Coils will trip instantaneously on line voltage. Dual coils require 30VA minimum power to trip and are rated for intermittent duty only.
6 Auxiliary Switch breakers with Series Trip & Switch Only circuits: ≤ 30A, are supplied with
standard half shells. 30-50A are supplied with extended boat (B-Style) half shells. 7 On multi-pole breakers, one auxiliary switch is supplied, mounted in the right pole. 8 Separate pole type voltage coils not rated for continuous duty. Available only with delay codes 10 & 20. 9 Available with Circuit Codes B & D only. VDE Certified to 30 amps. UL Recognized, CSA Accepted & TUV Certified to 50 amps.
10 Series Trip current ratings: VDE Certification available with single pole breakers with DC
Delay only. UL Recognition & CSA Accepted available in one and two pole breakers. 11 Screw Terminals are recommended on ratings greater than 20 amps. Ratings over 30 amps are only available with Terminal Codes 5, 9, G, H, M and Q.
12 Terminal Code 1: VDE Certification up to 25 amps and UL Recognition and CSA
Accepted up to 30 amps, but not recommended over 20 amps.
13 Terminal Codes 3, 5 E & H (Bus Type) with VDE, are supplied with Lock Washers;
Terminal Code M (M6 Threaded Stud) with VDE is supplied with Lock and Flat Washers. These breakers are only VDE Certified when the washers are used. 14 VDE Cert. available up to 12 amps. UL Rec. & CSA Accepted available up to 30 amps.
15 Single pole breakers with Terminal Code P (Printed Circuit Board) are available up to
30 amps with VDE Certification and 50 amps with UL Recognition and CSA Accepted, with Circuit Codes A, B & C.Two pole breakers with Terminal Code P (Printed Circuit Board) are available up to 40 amps with UL Recognition and CSA Certification with Circuit Codes A, B and C. 16 Terminal Code Q not available with VDE. 17 Terminal Code S used on voltage coil circuit constructions only. 18 Color shown is visi and legend with remainder of rocker black. 19 Dual = ON-OFF/I-O legend with actuator. None = no legend on actuator 20 Legend on Push-to-reset bezel/shroud is white with single color actuator codes R, & U. Legend on Push-to-reset bezel/shroud matches Visi-color of rocker with actuator codes N & O. Rockerguard available with actuator codes C through L. Actuator or Marking: Marking Color Visi-Color 12 I-O ON-OFF Dual 12 Single Color Visi-Rocker White A B 1 Black White Black C D 2 White n/a Red F G 3 White Red Green H J 4 White Green Blue K L 5 White Blue Yellow M N 6 Black Yellow Gray P Q 7 Black Gray Orange R S 8 Black Orange Sample Part Number A F 1 - B 0 - 24-630 - 2 3 1 - D Selection 1 2 3 4 5 6 7 8 9 10 11 Ordering Scheme Two Color Visi-Rocker C Indicate ON, vertical legend D Indicate ON, horizontal legend F Indicate OFF, vertical legend G Indicate OFF, horizontal legend H Indicate OFF, no legend Push-To-Reset, Visi-Rocker N Indicate OFF, vertical legend O Indicate OFF, horizontal legend P Indicate OFF, no legend Single color J Vertical legend K Horizontal legend L No legend Push-To-Reset , Single color R Vertical legend U Horizontal legend V No legend A 3 Switch Only (No Coil) G 4 Relay Trip (Voltage) B Series Trip (Current) H 4,5 Dual Coil with Shunt Trip C Series Trip (Voltage) Voltage Coil D 4 Shunt Trip (Current) K 4,5 Dual Coil with Relay Trip E 4 Shunt Trip (Voltage) Voltage Coil (Gold Contacts) A 2. ACTUATOR 1. SERIES 3. POLES 4. CIRCUIT 5. AUXILIARY / ALARM SWITCH 6. FREQUENCY & DELAY 7. CURRENT RATING (AMPERES) 8. TERMINAL STANDARD ROCKER BEZEL Threaded Insert, 2 per pole BARRIERS 1 6-32 x 0.195 inches no A 6-32 X 0.195 inches (multi-pole units only) yes B ISO M3 x 5mm (multi-pole units only) yes ROCKERGUARD & PUSH-TO-RESET BEZEL Threaded Insert, 2 per pole 3 6-32 x 0.195 inches no C 6-32 x 0.195 inches (multi-pole units only) yes
4 ISO M3 x 5mm no
D ISO M3 x 5mm (multi-pole units only) yes FRONT PANEL SNAP-IN BRACKET, 0.744” [18.90mm] wide bezel 8 without Rockerguard (single pole units only) no H with Rockerguard (single pole units only) no FRONT PANEL SNAP-IN BRACKET, 0.96” [24.48mm] wide bezel 9 without Rockerguard (single pole units only) no J with Rockerguard (single pole units only) no C UL Recognized & CSA Accepted D VDE Certified, UL Recognized & CSA Accepted E TUV Certified, UL Recognized & CSA Accepted I UL Recognized STD 1077, UL Recognized 1500 (ignition protected), & CSA Accepted 9. ACTUATOR COLOR & LEGEND 10. MOUNTING / BARRIERS 11. AGENCY APPROVAL VERTICAL STYLEHORIZONTAL STYLE CODE “C”CODE “D” CODE “F”, “N” CODE “J”, “R” CODE “G”, “O” CODE “k”, “U” INDICATE “ON”INDICATE “OFF”SINGLE COLOR LINE LINE LINELINE LINE LINE INDICATE COLOR LOCATION ROCKER STYLE DESCRIPTIONS 1 12 Push-On 0.250 Tab (Q.C.) 3 13 Screw 8-32 (Bus Type) 5 13 Screw 10-32 (Bus Type) lugs & 30° bend & 30° bend lugs & 30° bend & 30° bend B Screw M5 with upturned lugs C Screw, M4 with upturned lugs E 13 Screw M4 (Bus Type) F Screw M5 with upturned lugs & 30° bend G Screw M5 (Bus Type) & 30° bend H 13 Screw M5 (Bus Type) L 14 0.250 Q.C./ Solder Lug M 13 M6 Threaded Stud P 15 Printed Circuit Board Terminals Q Push-In Stud R Screw, M4 with upturned lugs & 30° Bend S 17 Push-On 0.110 Tab (Q.C.) & 30° bend T Screw, M4 with upturned lugs CODE AMPERES OR VOLTAGE COIL (NORMAL RATED VOLTAGE) 8 020 0.020 025 0.025 030 0.030 035 0.035 040 0.040 045 0.045 050 0.050 055 0.055 060 0.060 065 0.065 070 0.070 075 0.075 080 0.080 085 0.085 090 0.090 095 0.095 210 0.100 215 0.150 220 0.200 225 0.250 230 0.300 235 0.350 240 0.400 245 0.450 250 0.500 255 0.550 260 0.600 265 0.650 270 0.700 275 0.750 280 0.800 285 0.850 290 0.900 295 0.950 410 1.000 512 1.250 415 1.500 517 1.750 420 2.000 522 2.250 527 2.750 430 3.000 435 3.500 440 4.000 445 4.500 450 5.000 455 5.500 460 6.000 465 6.500 470 7.000 475 7.500 480 8.000 485 8.500 490 9.000 495 9.500 610 10.000 710 10.500 611 11.000 711 11.500 612 12.000 712 12.500 613 13.000 614 14.000 615 15.000 616 16.000 617 17.000 618 18.000 620 20.000 622 22.000 624 24.000 625 25.000 630 30.000 635 8 35.000 640 8 40.000 645 8 45.000 650 8 50.000 A06 6 DC A12 12 DC A18 18 DC A24 24 DC A32 32 DC A48 48 DC A65 65 DC J06 6 AC J12 12 AC J18 18 AC J24 24 AC J48 48 AC J65 65 AC K20 120 AC L40 240 AC Rocker UL 1077 Recognized Configure Complete Part Number > Browse Standard Parts >
- 1 6 Push-On 0.250 Tab (Q.C.)
3 7 Screw 8-32 (Bus Type) 5 7 Screw 10-32 (Bus Type) lugs & 30° bend & 30° bend lugs & 30° bend & 30° bend B Screw M5 with upturned lugs F Screw M5 with upturned lugs G Screw M5 (Bus Type) & 30° bend H Screw M5 (Bus Type) M 7 M6 Threaded Stud P 8 Printed Circuit Board Terminals Q 9 Push-In Stud Notes: 1 Push-To-Reset actuators have OFF portion of rocker shrouded.
2 Multi-pole breakers have all breakers identical except when specifying Auxiliary
switch and/or mixed poles, and have one rocker per breaker.
3 Auxiliary Switch breakers with Series Trip circuits: ≤ 30A, are supplied with standard
half shells. 30-50A are supplied with extended boat (B-Style) half shells. 4 VDE Certification available with single pole breakers only. UL489A Listing available with one and two pole breakers. 5 Screw Terminals are recommended on ratings greater than 20 amps. Ratings over 30 amps are only available with Terminal Codes 5, 9, G, H, M and Q.
6 Terminal Code 1 (Push-On) available up to 25 amps with TUV or VDE Certification
and 30 amps with UL489A Listing, but is not recommended over 20 amps.
7 Terminal Codes 3, 5 and H (Bus Type) with TUV or VDE, are supplied with Lock
Washers, and Terminal Code M (M6 Threaded Stud) with VDE is supplied with Lock and Flat Washers. These breakers are only TUV or VDE Certified when the washers are used.
8 Single pole breakers with Terminal Code P (Printed Circuit Board) are available up
to 30 amps with VDE Certification and 50 amps with UL489A Listing. 9 Terminal Code Q not available with VDE certification. 10 Color shown is Visi and Legend with remainder of rocker black. Dual = ON-OFF/I- O legend.
11 Legend on Push-to-reset bezel/shroud is white with single color actuator codes R
& U. Legend on Push-To-Reset bezel/shroud matches Visi-Color of rocker with actuator codes N & O. Rockerguard available with actuator codes C through K Actuator or Marking: Marking Color Visi-Color 10 ON-OFF Dual 10 Single Color Visi-Rocker White B 1 Black White Black D 2 White n/a Red G 3 White Red Green J 4 White Green Blue L 5 White Blue Yellow N 6 Black Yellow Gray Q 7 Black Gray Orange S 8 Black Orange Sample Part Number A F 1 - B 0 - 14 -450 - 1 3 1 - M T Selection 1 2 3 4 5 6 7 8 9 10 11 12 Ordering Scheme Two Color Visi-Rocker Push-To-Reset, Visi-Rocker C Indicate ON, vertical legend N Indicate OFF, D Indicate ON, horizontal legend vertical legend F Indicate OFF, vertical legend O Indicate OFF, horizontal G Indicate OFF, horizontal legend legend Single color Push-To-Reset , Single color J Vertical legend R Vertical legend K Horizontal legend U Horizontal legend B Series Trip (Current) (Gold Contacts)
52 DC, Short, High-inrush
54 DC, Medium, High-inrush
56 DC, Long, High-inrush
A 2. ACTUATOR 1. SERIES 3. POLES 4. CIRCUIT 5. AUXILIARY / ALARM SWITCH 6. FREQUENCY & DELAY 7. CURRENT RATING (AMPERES) 8. TERMINAL STANDARD ROCKER BEZEL Threaded Insert, 2 per pole BARRIERS 1 6-32 x 0.195 inches no A 6-32 X 0.195 inches (multi-pole units only) yes B ISO M3 x 5mm (multi-pole units only) yes ROCKERGUARD & PUSH-TO-RESET BEZEL Threaded Insert, 2 per pole 3 6-32 x 0.195 inches no C 6-32 x 0.195 inches (multi-pole units only) yes D ISO M3 x 5mm (multi-pole units only) yes FRONT PANEL SNAP-IN BRACKET, 0.744” [18.90mm] wide bezel 8 without Rockerguard (single pole units only) no H with Rockerguard (single pole units only) no FRONT PANEL SNAP-IN BRACKET, 0.96” [24.48mm] wide bezel 9 without Rockerguard (single pole units only) no J with Rockerguard (single pole units only) no M 80 DC T UL489A Listed K UL489A Listed, VDE Certified J UL489A Listed, TUV Certified 9. ACTUATOR COLOR & LEGEND 10. MOUNTING / BARRIERS 11. MAXIMUM APPLICATION RATING 12. AGENCY APPROVAL ROCKER STYLE DESCRIPTIONS VERTICAL STYLE HORIZONTAL STYLE FIG.B CODE “D” CODE “C” CODE “F”, “N” INDICATE “ON” INDICATE “OFF” SINGLE COLOR CODE “J”, “R”LINE LINE INDICATE COLOR LOCATION LINE LINE LINE LINE CODE AMPERES 210 0.100 215 0.150 220 0.200 225 0.250 230 0.300 235 0.350 240 0.400 245 0.450 250 0.500 255 0.550 260 0.600 265 0.650 270 0.700 275 0.750 280 0.800 285 0.850 290 0.900 295 0.950 410 1.000 512 1.250 415 1.500 517 1.750 420 2.000 522 2.250 527 2.750 430 3.000 435 3.500 440 4.000 445 4.500 450 5.000 455 5.500 460 6.000 465 6.500 470 7.000 475 7.500 480 8.000 485 8.500 490 9.000 495 9.500 610 10.000 710 10.500 611 11.000 711 11.500 612 12.000 712 12.500 613 13.000 614 14.000 615 15.000 616 16.000 617 17.000 618 18.000 620 20.000 622 22.000 624 24.000 625 25.000 630 30.000 6354 35.000 6404 40.000 6454 45.000 6504 50.000 Rocker - UL 489A Listed Configure Complete Part Number > Browse Standard Parts >
- Notes: 1 Tolerance ±.020 [.51] unless otherwise specified. 2 Schematic shown represents current trip circuit. 3 Circuits shown for >30 amps / VDE. *AVAILABLE ON SERIES TRIP AND SWITCH ONLY CIRCUITS WHEN CALLED FOR ON MULTI-POLE UNITS, ONLY ONE AUX. SWITCH IS NORMALLY SUPPLIED, AS SHOWN IN MULTI-POLE INDENTIFICATION SHEME. 1.560 [39.62] SEE TABLE-B DEPTH BEHIND PANEL LINE (NETZ) (LAST) LOAD M6 STUD PUSH-IN STUD SCREW TERMINAL WITH 30 BEND
.370 [9.40] .390 [9.91] .390 [9.91] .205 [5.21] 1.640 [41.66] AUX. SWITCH TERMINALS MAIN TERMINALS (SEE TABLE A) LINE CIRCUIT BREAKER PROFILE CIRCUIT SCHEMATIC SWITCH ONLY (NO COIL) WITH AUXILIARY SWITCH DUAL COIL; SERIES TRIP CURRENT COIL, SHUNT TRIP VOLTAGE COIL SHUNT TRIP SHUNT SWITCH ONLY (NO COIL) ANSI IEC LOAD LINE LOAD LINE (NETZ) (LAST) LOAD CIRCUIT SCHEMATIC ANSI SERIES TRIP IEC CIRCUIT CODE AUX SWITCH CODE CIRCUIT CODE AUX SWITCH CODE LINE LOAD LINE LOADLOAD LINE(NETZ) (3) (3) (4) (3) (3) SERIES TRIPSWITH AUXILIARY SWITCH (4) A 0 B C B C H 0 K 0 D E F G A (LAST)LOAD LINE(NETZ)LINE(NETZ) (LAST)LOAD(LAST)LOAD LINE LOAD LINE LOAD RELAY LOAD (LAST)(RELAIS) RELAY (RELAIS) RELAY (RELAIS) LINE RELAY RELAY TRIP SHUNT (NEBENSCHLUSS) LINE(NETZ) (LAST)LOAD VOLTAGE COIL VOLTAGE COIL LINE LINE LOAD LINE(NETZ) (LAST) LOAD I > I > I > I > I > U > NC NO C NC NO C NC NO C NC NO C NC NO C NC NO C ALARM SWITCH TERMINALS & STD. AUX. SW. WITH VDE OR >30 AMPS .520 [13.21] .780 [19.81]
4 TERMINALS
1.640 [41.66]REF .032 [.81]TYP .220 [5.59] 1.936 [49.17] TYP .393 [9.96]REF 1.350 [34.29] 1.560 [39.62]TYP TABLE B .520 [13.21] 2.000 [50.80] BARRIER FOR UL-RECOGNIZED MULTI-POLE BREAKERS 2.370[60.20] 2.577[65.46] 2.734[69.44] TAB (Q.C.) TAB (Q.C.) 2.340[59.44]SOLDER TYPE MAIN SHUNT,RELAY DUAL COIL AUX. SWITCH* SCREW #8-32 W/UPTURNED LUGS 2.402[61.01]SCREW TYPE LINE LOAD TERMINAL DESCRIPTION DEPTH BEHIND PANEL .020 [.51]TYP Circuit & Terminal Diagrams inches [millimeters] Rocker
- INDICATE “ON” INDICATE “OFF” & SINGLE COLOR (INDICATE “OFF” SHOWN) OPTIONAL “ROCKER GUARD”.945 [24.00] #6-32 [M3] THREAD X.195[4.95]DEEP
OF ROCKER,& PANEL CUT-OUT ROCKER SHROUDED ON “OFF” POSITION SIDE, SHOWN IN DASHED LINES OPTIONAL “ROCKER GUARD” SHOWN IN DASHED LINES REAR VIEW OF INDICATE “OFF” SERIES TRIP W/AUX SWITCH CIRCUIT CONFIGURATION P(1) P(2) P(3) (SEE NOTE 2) REAR VIEW OF INDICATE “ON” SERIES TRIP W/AUX SWITCH CIRCUIT CONFIGURATION P(1) P(2) P(3) (SEE NOTE 2) .055x.205 SLOTTED HOLE (ROCKER OFF ACTUATION) OPTIONAL “PUSH-TO RESET” ACTUATOR 2.156 [54.76] 1.245 [31.62] 1.660 [42.16] .745 [18.92] ROCKER ADAPTER BRACKET WIDTH MAX REF TAB TYPE .208 [5.27] .370 [9.40] .420 [10.67] 1.560 [39.62] 2.000 [50.80] .945 [24.00] 2.309 [58.65] 1.010 [25.65].465 [11.81] .432 [10.97] LOAD AF1 AF2 PANEL CUT-OUT DETAIL AF3AC3 AC2 AC1 LINE LOAD LINE LOAD LINE LOAD LINE LOAD LINE LOAD LINE LOAD LINE .120 [3.05] .755 [19.18] BREAKER WIDTH 2.265 [57.53] MAX 1.515 [38.48] MAX 1.660 [42.16] TYP 1.660 [42.16] TYP .220 [5.59] 1.260 [32.00] .200 [5.08] 1.660 [42.16] .156 DIA[ 3.96]
2 HOLES
.750 [19.05] .432 [10.97] 1.640 [41.66] 2.370 [60.20] SCREW TYPE 2.402 [61.20] 1.245 [31.62] TYP .750 [19.05] TYP + .005 _[+ .13] _+ .005 _[+ .13] -.000 + .005 _[+ .25] _[+ .00] TAB (Q.C.) TYPE TERMINALS IN SERIES TRIP CONCUIT CONFIGURATION SHOWN> FOR OTHER CONFIGURATIONS SEE CIRCUIT & TERMINAL DIAGRAMS Notes: 1 Dimensions apply to all variations shown. Notice that circuit breaker line & load terminal orientation on indicate OFF is opposite of indicate ON. 2 For pole orientation with horizontal legend, rotate front view clockwise 90°. 3 Tolerance ± 0.20 [.51] unless otherwise specified. Dimensional Specs inches [millimeters] Rocker
- INDICATE “ON” INDICATE “OFF” FRONT PANEL SNAP-IN BRACKET , 0.96”[24.48 mm] wide bezel FRONT PANEL SNAP-IN BRACKET , 0.744”[18.90 mm] wide bezel FRONT PANEL SNAP-IN BRACKET , 0.96 ”[24.48 mm] wide bezel FRONT PANEL SNAP-IN BRACKET , 0.744 ”[18.90 mm] wide bezel PANEL CUTOUT DETAIL MAX .755 [19.18] BREAKER WIDTH TAB (Q.C.) TYPE TERMINALS IN SERIES TRIP CONCUIT CONFIGURATION SHOWN. FOR OTHER CONFIGURATIONS SEE CIRCUIT & TERMINAL DIAGRAMS MAX .960 [24.38] .320 [8.13] .410 [10.41] .125 [3.18]AC1 2.598 [65.99] ROCKER ADAPTER BREAKER WIDTH MAX .744 [18.90] 2.598 [65.99] ROCKER ADAPTER BREAKER WIDTH MAX .755 [19.18] 1.640 [41.66] 2.000 [50.80] 1.560 [39.62] .320 [8.13] 2.98 [65.99] .483 [12.27] .125 [3.18] .320 [8.13] OPTIONAL “ROCKER GUARD” SHOWN IN DASHED LINES .125 [3.18] .410 [10.41] ROCKER ADAPTER BREAKER WIDTH MAX .960 [24.38] ROCKER ADAPTER BREAKER WIDTH MAX .744 [18.90] 2.598 [65.99] ROCKER ADAPTER BREAKER WIDTH TAB TYPE 1.640 [41.66] 2.370 [58.93] 1.560 [39.62] 2.000 [50.80] .320 [8.13] .125 [3.18] .483 [12.27] SCREW TYPE 2.352 [59.74] AC1 AF1 AF1 LOAD LINE LOAD LINE LOAD LINE OPTIONAL”ROCKER GUARD” SHOWN IN DASHED LINES .770 [19.56] _+ .010 _[+ .25] 2.187 [55.55] _+ .012 _[+ .30] Notes: 1 Dimensions apply to all variations shown. Notice that circuit breaker line & load terminal 2 For pole orientation with horizontal legend, rotate front view clockwise 90°. Orientation on indicate “OFF” is opposite of indicate “ON” 3 Recommended panel thickness: .04 0 [1.02] to .100 [2.54] 4 Tolerance ±.020 [.51] unless otherwise specified. Dimensional Specs inches [millimeters] Rocker Snap-In Bracket
- A-SERIES ROCKER A-SERIES HANDLE TYP .125 [3.17] TYP .375 [9.53] TYP +.003_ .030 [.762] TYP +.003 .030 [.762] TYP .125 [3.17] TYP .375 [9.53] 2.122 [53.90] 1.640 [41.66].693 [17.50] OFF ON .221 [5.61] 2.000 [50.80] .632 [16.05] 2.122 [53.90] .130 [3.30] .590 DIA [ 14.99] .060 DIA[ 1.52] 14 THRU HOLES .060 DIA[ 1.52]
17 THRU HOLES
P.C. FOOT PRINT P.C. FOOT PRINT WITH AUX. SWITCH 1.558 [39.57] 2 PL .632 [16.05] REF .370 [9.40] .120 [3.05] 2.309 [58.65] 1.245 [31.62] 1.010 [25.65] 3 PL .145 [3.68]3 PL .145 [3.68] MAX .745 [18.92] .221 [5.61] 2.000 [50.80] 1.558 [39.57] .755 [19.18] MAX BREAKER WIDTH .1640 [41.66] .520 [13.21] .050 DIA[ 1.27] (2 PL) (2 PL) .096 [2.44] MAX .745 [18.92] (2 PL) .096 [2.44] (2 PL) .096 [2.44] TYP .100 [2.54] .544 [13.82] 2.122 [53.90] TYP .100 [2.54] .544 [13.82] .050 [1.27] .295 [7.49] 1.528 [38.81] .295 [7.49] 1.528 [38.81] .050 DIA[ 1.27] (2 PL) .475 [12.07] 2.122 [53.90] FIBER .0427 [1.19].420 [10.67] LOAD LINE .755 [19.18] MAX BREAKER WIDTH LOAD LINE NC NO C Notes: 1 Drawing illustrates A-Series with VDE certification. 2 Tolerance ± 0.20 [.51] unless otherwise specified PC Terminal Diagrams inches [millimeters]
22. 20 6 50/60Hz Instantaneous 21 50/60Hz Ultra Short 22 50/60Hz Short 24 50/60Hz Medium 26 50/60Hz Long 42 9 50/60Hz Short, High-inrush 44 9 50/60Hz Medium, High-inrush 46 9 50/60Hz Long, High-inrush 52 9 DC, Short, High-inrush 54 9 DC, Medium, High-inrush Notes: 1 Push-To-Reset actuators have OFF portion of rocker shrouded. switch and/or mixed poles, and have one rocker per breaker. 3 Switch Only circuits, rated up to 50 amps & 3 poles. Only available when tied to a protected pole. For .02 to 30 amps, select Current Code 630. For 35 - 50 amps, select Current Code 650. 4 Available with terminal Codes 1, 2 and 3. Current Rating limited to 30 amps maximum. 5 Consult factory for Dual Coil options, as special catalog number is required. With Shunt construction, Dual Coils will trip instantaneously on line voltage. Dual coils require 30VA minimum power to trip and are rated for intermittent duty only.
6 Auxiliary Switch breakers with Series Trip & Switch Only circuits: ≤ 30A, are supplied
with standard half shells. 30-50A are supplied with extended boat (B-Style) half shells.
7 On multi-pole breakers, one auxiliary switch is supplied, mounted in the extreme right
pole. 8 Separate pole type voltage coils not rated for continuous duty. Available only with delay codes 10 & 20. 9 Available with Circuit Codes B & D only. UL Recognized, CSA Accepted & TUV Certified to 50 amps.
10 UL Recognition, CSA Acceptance & TUV Certification available in one and two pole
breakers. 11 Screw Terminals are recommended on ratings greater than 20 amps. Ratings over 30 amps are only available with Terminal Codes 5, 9, G, H, M and Q. 12 Terminal Code 1: Available up to 30 amps, but not recommended over 20 amps.
13 Terminal Codes 3, 5 E & H (Bus Type) with TUV, are supplied with Lock Washers;
Terminal Code M (M6 Threaded Stud) with TUV is supplied with Lock and Flat Washers. These breakers are only TUV Certified when the washers are used. 14 TUV Cert. available up to 12 amps. UL Rec. & CSA Accepted available up to 30 amps. 50 amps with UL Recognition, CSA Accepted & TUV Certification, with Circuit Codes A, B and C. Two pole breakers with Terminal Code P (Printed Circuit Board) are avail able up to 40 amps with UL Recognition and CSA Accepted with Circuit Codes A, B & C. 16 Terminal Code S used on voltage coil circuit constructions only. 17 Color shown is visi & legend with remainder of rocker black, Dual = ON-OFF/I-O legend.
18 Legend on Push-to-reset bezel/shroud is white with single color actuator codes 7 &
- Legend on Push-To-Reset bezel/shroud matches Visi-Color of rocker with actuator codes 5 & 6. 19 Recessed “off-side” available with actuator codes 1, 2, 3 & 4. Legends on rocker are available in ink stamping only. Sample Part Number A 1 1 - B 0 - 24-630 - 2 3 1 - E Selection 1 2 3 4 5 6 7 8 9 10 11 Ordering Scheme Two Color Visi-Rocker
1 Indicate OFF, vertical legend
2 Indicate OFF, horizontal legend
3 Vertical legend
4 Horizontal legend
Push-To-Reset, Visi-Rocker
5 Indicate OFF, vertical legend
6 Indicate OFF, horizontal legend
Push-To-Reset , Single color
7 Vertical legend
8 Horizontal legend
A 3 Switch Only (No Coil) G 4 Relay Trip (Voltage) B Series Trip (Current) H 4,5 Dual Coil with Shunt Trip C Series Trip (Voltage) Voltage Coil D 4 Shunt Trip (Current) K 4,5 Dual Coil with Relay Trip E 4 Shunt Trip (Voltage) Voltage Coil F 4 Relay Trip (Current) (Gold Contacts) A 2. ACTUATOR 1. SERIES 3. POLES 4. CIRCUIT 5. AUXILIARY / ALARM SWITCH 6. FREQUENCY & DELAY 7. CURRENT RATING (AMPERES) 8. TERMINAL 6,7 STANDARD ROCKER BEZEL Threaded Insert, 2 per pole BARRIERS FLAT ROCKER ACTUATOR 1 6-32 x 0.195 inches no A 6-32 X 0.195 inches (multi-pole units only) yes B ISO M3 x 5mm (multi-pole units only) yes RECESSED OFF SIDE ROCKER ACTUATOR 19 5 6-32 x 0.195 inches no E 6-32 x 0.195 inches (multi-pole units only)yes
6 ISO M3 x 5mm no
F ISO M3 x 5mm (multi-pole units only) yes PUSH-TO-RESET BEZEL,Threaded Insert, 2 per pole 3 6-32 x 0.195 inches no C 6-32 x 0.195 inches (multi-pole units only) yes D ISO M3 x 5mm (multi-pole units only) yes C UL Recognized & CSA Accepted E TUV Certified, UL Recognized & CSA Accepted I UL Recognized STD 1077, UL Recognized 1500 (ignition protected), & CSA Accepted 9. ACTUATOR COLOR & LEGEND 10. MOUNTING / BARRIERS 11. AGENCY APPROVAL Actuator or Marking: Marking Color Visi-Color 17 ON-OFF Dual 17 Single Color Visi-Rocker White B 1 Black White Black D 2 White n/a Red G 3 White Red Green J 4 White Green Blue L 5 White Blue Yellow N 6 Black Yellow Gray Q 7 Black Gray Orange S 8 Black Orange ROCKER STYLE DESCRIPTIONS INDICATE”OFF” HORIZONTAL STYLE VERTICAL STYLE SINGLE COLOR INDICATE COLOR LOCATION LINE LINE LINE LINE 1 12 Push-On 0.250 Tab (Q.C.) 3 13 Screw 8-32 (Bus Type) 5 13 Screw 10-32 (Bus Type) lugs & 30° bend & 30° bend lugs & 30° bend & 30° bend B Screw M5 with upturned lugs C Screw, M4 with upturned lugs E 13 Screw M4 (Bus Type) F Screw M5 with upturned lugs & 30° bend G Screw M5 (Bus Type) & 30° bend H 13 Screw M5 (Bus Type) L 14 0.250 Q.C./ Solder Lug M 13 M6 Threaded Stud P 15 Printed Circuit Board Terminals Q Push-In Stud R Screw, M4 with upturned lugs & 30° Bend S 16 Push-On 0.110 Tab (Q.C.) & 30° bend T Screw, M4 with upturned lugs CODE AMPERES OR VOLTAGE COIL (NORMAL RATED VOLTAGE) 8 020 0.020 025 0.025 030 0.030 035 0.035 040 0.040 045 0.045 050 0.050 055 0.055 060 0.060 065 0.065 070 0.070 075 0.075 080 0.080 085 0.085 090 0.090 095 0.095 210 0.100 215 0.150 220 0.200 225 0.250 230 0.300 235 0.350 240 0.400 245 0.450 250 0.500 255 0.550 260 0.600 265 0.650 270 0.700 275 0.750 280 0.800 285 0.850 290 0.900 295 0.950 410 1.000 512 1.250 415 1.500 517 1.750 420 2.000 522 2.250 527 2.750 430 3.000 435 3.500 440 4.000 445 4.500 450 5.000 455 5.500 460 6.000 465 6.500 470 7.000 475 7.500 480 8.000 485 8.500 490 9.000 495 9.500 610 10.000 710 10.500 611 11.000 711 11.500 612 12.000 712 12.500 613 13.000 614 14.000 615 15.000 616 16.000 617 17.000 618 18.000 620 20.000 622 22.000 624 24.000 625 25.000 630 30.000 635 8 35.000 640 8 40.000 645 8 45.000 650 8 50.000 A06 6 DC A12 12 DC A18 18 DC A24 24 DC A32 32 DC A48 48 DC A65 65 DC J06 6 AC J12 12 AC J18 18 AC J24 24 AC J48 48 AC J65 65 AC K20 120 AC L40 240 AC Flat Rocker - UL 1077 Recognized Configure Complete Part Number > Browse Standard Parts >
- CODE AMPERES 020 0.020 025 0.025 030 0.030 035 0.035 040 0.040 045 0.045 050 0.050 055 0.055 060 0.060 065 0.065 070 0.070 075 0.075 080 0.080 085 0.085 090 0.090 095 0.095 210 0.100 215 0.150 220 0.200 225 0.250 230 0.300 235 0.350 240 0.400 245 0.450 250 0.500 255 0.550 260 0.600 265 0.650 270 0.700 275 0.750 280 0.800 285 0.850 290 0.900 295 0.950 410 1.000 512 1.250 415 1.500 517 1.750 420 2.000 522 2.250 527 2.750 430 3.000 435 3.500 440 4.000 445 4.500 450 5.000 455 5.500 460 6.000 465 6.500 470 7.000 475 7.500 480 8.000 485 8.500 490 9.000 495 9.500 610 10.000 710 10.500 611 11.000 711 11.500 612 12.000 712 12.500 613 13.000 614 14.000 615 15.000 616 16.000 617 17.000 618 18.000 620 20.000 622 22.000 624 24.000 625 25.000 630 30.000 6354 35.000 6404 40.000 6454 45.000 6504 50.000
56 DC, Long, High-inrush Notes:
1 Push-To-Reset actuators have OFF portion of rocker shrouded. switch and/or mixed poles, and have one rocker per breaker.
3 Auxiliary Switch breakers with Series Trip circuits: ≤ 30A, are supplied with
standard half shells. 30-50A are supplied with extended boat (B-Style) half shells. 4 VDE Certification available with single pole breakers only. UL489A Listing avail able with one and two pole breakers. 5 Screw Terminals are recommended on ratings greater than 20 amps. Ratings over 30 amps are only available with Terminal Codes 5, 9, G, H, M and Q. and 30 amps with UL489A Listing, but is not recommended over 20 amps. Washers, and Terminal Code M (M6 Threaded Stud) with VDE is supplied with Lock and Flat Washers. These breakers are only TUV or VDE Certified when the washers are used.
8 Single pole breakers with Terminal Code P (Printed Circuit Board) are available
up to 30 amps with VDE Certification and 50 amps with UL489A Listing. 9 Terminal Code Q not available with VDE certification. 10 Color shown is Visi and Legend with remainder of rocker black. Dual = ON-OFF/I- O legend.
11 Legend on Push-to-reset bezel/shroud is white with single color actuator codes
R & U.
12 Legend on Push-To-Reset bezel/shroud matches Visi-Color of rocker with actua
tor codes N & O. Rockerguard available with actuator codes C through K Two Color Visi-Rocker Push-To-Reset, Visi-Rocker Push-To-Reset , Single color B Series Trip (Current) A 2. ACTUATOR 1. SERIES 3. POLES 4. CIRCUIT 5. AUXILIARY / ALARM SWITCH 6. FREQUENCY & DELAY 7. CURRENT RATING (AMPERES) 8. TERMINAL STANDARD ROCKER BEZEL BARRIERS Threaded Insert, 2 per pole FLAT ROCKER ACTUATOR 1 6-32 x 0.195 inches no A 6-32 X 0.195 inches (multi-pole units only) yes B ISO M3 x 5mm (multi-pole units only) yes RECESSED OFF SIDE ROCKER ACTUATOR 5 6-32 x 0.195 inches no E 6-32 x 0.195 inches (multi-pole units only) yes F ISO M3 x 5mm (multi-pole units only) yes PUSH-TO-RESET BEZEL,Threaded Insert, 2 per pole 3 6-32 x 0.195 inches no C 6-32 x 0.195 inches (multi-pole units only) yes D ISO M3 x 5mm (multi-pole units only) yes M 80 DC T UL489A Listed J UL489A Listed, TUV Certified 9. ACTUATOR COLOR & LEGEND 10. MOUNTING / BARRIERS 11. MAXIMUM APPLICATION RATING 12.AGENCY APPROVAL Sample Part Number A 1 1 - B 0 - 14 -630 - 2 3 1 - M T Selection 1 2 3 4 5 6 7 8 9 10 11 12 Ordering Scheme Actuator or Marking: Marking Color Visi-Color 11 ON-OFF Dual 11 Single Color Visi-Rocker White B 1 Black White Black D 2 White n/a Red G 3 White Red Green J 4 White Green Blue L 5 White Blue Yellow N 6 Black Yellow Gray Q 7 Black Gray Orange S 8 Black Orange ROCKER STYLE DESCRIPTIONS INDICATE”OFF” HORIZONTAL STYLE VERTICAL STYLE SINGLE COLOR INDICATE COLOR LOCATION LINE LINE LINE LINE 3 7 Screw 8-32 (Bus Type) 5 7 Screw 10-32 (Bus Type) lugs & 30° bend lugs & 30° bend & 30° bend B Screw M5 with upturned lugs F Screw M5 with upturned lugs G Screw M5 (Bus Type) & 30° bend H Screw M5 (Bus Type) M 7 M6 Threaded Stud P 8 Printed Circuit Board Terminals Q 9 Push-In Stud Flat Rocker - UL 489A Listed Configure Complete Part Number > Browse Standard Parts >
- INDICATE “OFF” & SINGLE COLOR (INDICATE “OFF” SHOWN) #6-32 [M3] THREAD X.195[4.95]DEEP
1.245 [31.62] REF TAB TYPE .208 [5.27] .370 [9.40] MAX .745 [18.92] 1.660 [42.16] 1.010 [25.65] 2.309 [58.65] .397 [10.08] .120 [3.05] 1.640 [41.66] 2.000 [50.80] 1.560 [39.62] 2.370 [60.20] SCREW TYPE 2.402 [61.01] ROCKER ADAPTER BRACKET WIDTH CENTER-LINEOF ROCKER &PANEL CUT-OUT TAB (Q.C.) TYPE TERMINALS IN SERIES TRIP CONCUIT CONFIGURATION SHOWN. FOR OTHER CONFIGURATIONS SEE CIRCUIT & TERMINAL DIAGRAMS A11 LOAD LINE A12 PANEL CUT-OUT DETAIL PUSH-TO-RESET ACTUATOR ACTUATOR SIDE VIEW A13 A51 LOAD LINE LOAD LINE LOAD LINE 1.515 [38.48] MAX 2.265 [57.53] MAX 1.660 [42.16] 1.660 [42.16] TYP .220 [5.59] 1.260 [32.00] .200 [5.08] 1.245 [31.62] SIDE VIEW OF BREAKER IN THE “ON” POSITION .515 [13.08] 2.309 [58.65] 1.010 [25.65] 1.660 [42.16] .156 DIA[ 3.96] .750 [19.05] TYP .750 [19.05] TYP + .005 _[+ .13] _+ .005 _[+ .13] -.000 + .005 _[+ .25] _[+ .00] REAR VIEW OF INDICATE “OFF” SERIES TRIP W/AUX SWITCH CIRCUIT CONFIGURATION ROCKER SHROUDED ON “OFF” POSITION SIDE, SHOWN IN DASHED LINES (SURFACE CONTOURS) FLAT ROCKER RECESSED OFF SIDE ROCKER P(1) P(2) P(3) (SEE NOTE 2) SLOTTED HOLE (ROCKER OFF ACTUATION) .055x.205 MAX .755 [19.18] BREAKER WIDTH Notes: 1 For pole orientation with horizontal legend, rotate front view clockwise 90°. 2 Tolerance ± 0.20 [.51] unless otherwise specified. Dimensional Specs inches [millimeters] Flat Rocker
- CODE AMPERES OR VOLTAGE COIL (NORMAL RATED VOLTAGE) Y Single Color Recessed Paddle Actuator with Vertical Legends 020 0.020 025 0.025 030 0.030 035 0.035 040 0.040 045 0.045 050 0.050 055 0.055 060 0.060 065 0.065 070 0.070 075 0.075 080 0.080 085 0.085 090 0.090 095 0.095 210 0.100 215 0.150 220 0.200 225 0.250 230 0.300 235 0.350 240 0.400 245 0.450 250 0.500 255 0.550 260 0.600 265 0.650 270 0.700 275 0.750 280 0.800 285 0.850 290 0.900 295 0.950 410 1.000 512 1.250 415 1.500 517 1.750 420 2.000 522 2.250 527 2.750 430 3.000 435 3.500 440 4.000 445 4.500 450 5.000 455 5.500 460 6.000 465 6.500 470 7.000 475 7.500 480 8.000 485 8.500 490 9.000 495 9.500 610 10.000 710 10.500 611 11.000 711 11.500 612 12.000 712 12.500 613 13.000 614 14.000 615 15.000 616 16.000 617 17.000 618 18.000 620 20.000 622 22.000 624 24.000 625 25.000 630 30.000 635 35.000 640 40.000 645 45.000 650 50.000 A06 6 DC A12 12 DC A18 18 DC A24 24 DC A32 32 DC A48 48 DC A65 65 DC J06 6 AC J12 12 AC J18 18 AC J24 24 AC J48 48 AC J65 65 AC K20 120 AC L40 240 AC
3 DC, 50/60 Hz Switch Only
42 50/60 Hz Short High-inrush 44 50/60 Hz Medium High-inrush 46 50/60 Hz Long High-inrush Notes: 1 A l l s t a n d a r d c a t a l o g n u m b e r s a r e s u p p l i e d w i t h V e r t i c a l L e g e n d s . F o r H o r i z o n t a l or other non-standard legends, choose “X” and order as a special catalog number. 2 For rating (T) 2 & 3 Pole not available.
3 Frequency and Time Delay ratings of (03, 20, 21, 22, 24, 26, 42, 44, 46) not
available with approval T. 4 Voltage Coil Ratings starting with (J, K, or L) not available with approval T. 5 “ O F F a n d / o r “ O ” L e g e n d s a r e o n B r a c k e t a n d a r e o n l y v i s i b l e w h e n t h e P a d d l e Actuator is in the off position. 6 Maximum Application Ratings (C & K) not available with approval T. 7 Not all approvals are available in all constructions. Consult factory for details. A Switch-Only (No Coil) F Relay Trip (Current) B Series Trip (Current) G Relay Trip (Voltage) C Series Trip (Voltage) H Dual Coil with Shunt Trip Voltage Coil D Shunt Trip (Current) K Dual Coil with Shunt Trip Current Coil E Shunt Trip (Voltage) 0 without Aux Switch A 2. ACTUATOR 1. SERIES 3. POLES 4. CIRCUIT 5. AUXILIARY SWITCH 6. FREQUENCY & DELAY 7. CURRENT RATING (AMPERES) 8. TERMINAL BARRIERS 1 6-32 x 0.195 inches no A 6-32 X 0.195 inches (multi-pole units only) yes B ISO M3 x 5mm (multi-pole units only) yes A 65 VDC C 120/240 VAC (Available only on 2 or 3-Pole units) K 120 VAC M 80 DC A Without Approvals C UL Recognized and CSA Accepted T UL 489A 9. ACTUATOR COLOR & LEGEND 10. MOUNTING / BARRIERS 11. MAXIMUM APPLICATION RATING 12.AGENCY APPROVAL Sample Part Number A Y 1 - B 0 - 14 -630 - 2 3 1 - M T Selection 1 2 3 4 5 6 7 8 9 10 11 12 Ordering Scheme Actuator Color I-O ON-OFF Dual Legend Color White A B 1 Black Black C D 2 White Red F G 3 White Green H J 4 White Blue K L 5 White Yellow M N 6 Black Gray P Q 7 Black Orange R S 8 Black 1 Push-On 0.250 Tab (Q.C.) 3 7 Screw 8-32 (Bus Type) 5 7 Screw 10-32 (Bus Type) lugs & 30° bend & 30° bend lugs & 30° bend & 30° bend B Screw M5 with upturned lugs C Screw, M4 with upturned lugs F Screw M5 with upturned lugs G Screw M5 (Bus Type) & 30° bend H Screw M5 (Bus Type) M M6 Threaded Stud P Printed Circuit Board Terminals Q Push-In Stud R Screw, M4 with upturned lugs & 30° Bend S Screw, M5 with upturned lugs T Screw, M4 with upturned lugs Recessed Paddle Configure Complete Part Number > Browse Standard Parts >
- Notes: 1 Tolerance ± 0.20 [.51] unless otherwise specified BREAKER SHOWN IN THE OFF POSITION PANEL CUT-OUTDETAIL BREAKER SHOWN IN THE OFF POSITION TAB TYPE 2.010 [51.05] .380 [9.65] 1.240 [31.50] 2.000 [50.80] 1.560 [39.62]1.660 [42.16] .243 [6.17]2.10 [5.33] 2.378 [60.40] SCREW TYPE 2.410 [61.21] LOAD LINE MAX .745 [18.92] MAX TYP .755 [19.18] .750 [19.05] TYP .750 [19.05] MAX 1.515 [38.48] MAX 2.265 [57.53] .200 [5.08] 1.660 [42.16] .848 [21.54] 2.888 [73.36] #6-32 [M3] THREAD X .105 [4.95] DEEP
.156 + .005 [3.96 + .12]- -2 HOLES 1.260 + .005 [32.00+ .12]- + .010 [ 19.05 ] -.000 + .25 - .00 .750 Dimensional Specs inches [millimeters] Recessed Paddle
- Authorized Sales Representatives and Distributors About Carling Founded in 1920, Carling Technologies is a leading manufacturer of electrical and electronic switches and assemblies, circuit breakers, electronic controls, power distribution units, and multiplexed power distribution systems. With six ISO9001 and IATF16949 registered manufacturing facilities and technical sales offices worldwide, Carling Technologies Sales, Service and Engineering teams do much more than manufacture electrical components, they engineer powerful solutions! To learn more about Carling please visit www.carlingtech.com/company-profile. To view all of Carling’s environmental, quality, health & safety certifications please visit www.carlingtech.com/environmental-certifications. Click on a region of the map below to find your local representatives and distributors or visit www.carlingtech.com/findarep. EUROPE MIDDLE EAST SOUTH AMERICA ASIA-PACIFIC OCEANIA AFRICA MEXICO USA CANADA © Carling Technologies, Inc. Carling, Visi-Rocker are registered trademarks of Carling Technologies, Inc. in the U.S. and other countries.