0.75 Watt | DC-DC Converter
www.aimtec.com Tel: +1 514 620 2722 Toll free: + 1 888 9 AIMTEC (924 6832) F 051e R11.E 1 of 3 North America only FEATURES: Models Single output Model Input Voltage (V) Output Voltage (V) Output Current Max / Min (mA) Isolation (VDC) Max. Capacitive Load (µF) Efficiency (%) AM1SR-0503SJZ 4.75-5.25 3.3 200 / 20 1500 2400 68 AM1SR-0505SJZ 4.75-5.25 5 150 / 15 1500 2400 72 AM1SR-0509SJZ 4.75-5.25 9 83 / 9 1500 1000 72 AM1SR-0512SJZ 4.75-5.25 12 62 / 7 1500 560 73 AM1SR-0515SJZ 4.75-5.25 15 50 / 5 1500 560 74 Input Specifications Parameters Nominal Typical Maximum Units Voltage range 5 4.75-5.25 VDC Input current (Full load/No load) 3.3VDC, 5VDC 9VDC, 12VDC 15VDC mA Filter Capacitor Reflected ripple current 15 mA Isolation Specifications Parameters Conditions Typical Rated Units Tested I/O voltage 60 sec 1500 VDC Resistance > 1000 MOhm Capacitance 20 pF Output Specifications Parameters Conditions Typical Maximum Units Voltage accuracy ±3 % Short Circuit protection Continuous Line voltage regulation Input voltage: ±5% ±1.25 % of Vin Load voltage regulation Load 10 – 100% for 3.3V model Load 10 – 100% for other models ±3 ±2 % Temperature coefficient ±0.02 %/oC Ripple & Noise At 20 MHz Bandwidth 30 75 mV p-p General Specifications Parameters Conditions Typical Maximum Units Switching frequency 100% load 270 KHz Operating temperature Derating Above 71oC -40 to +85 oC Storage temperature -55 to +125 oC Maximum case temperature 125 oC Cooling Free air convection Humidity Non condensing 95 % Soldering Lead Temperature 1.5mm from Lead, for 10 Sec 300 oC Case material Plastic UL94-VO Weight 1.3 g MTBF >3500K hrs(MIL-HDBK -217F, Ground Benign, t=+25oC)
- Design to meet UL/EN 62368 • Operating temperature -40oC to +85oC
- 4 Pin SIP Package • Input / Output isolation 1500 VDC
- 5mA low no load current • Pin compatible with multiple manufacturers
- High efficiency up to 74% • Continuous Short Circuit Protection Click on Series name for product info on aimtec.com
www.aimtec.com Tel: +1 514 620 2722 Toll free: + 1 888 9 AIMTEC (924 6832) F 051e R11.E 2 of 3 North America only NOTE: All specifications in this datasheet are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at rated output load unless otherwise specified. Safety Specifications Parameters Agency approvals Design to meet IEC/EN/UL62368, pending approval Standards CISPR32/EN55032 Class B, with the recommended circuit below IEC/EN 61000-4-2, Air +/-8kV, Contact +/-4kV, Criteria B Pin Out Specifications Dimensions XXXX 11.60 (0.46) 10.16 (0.40) 0.50 (0.02) 4.10 (0.161) 6.00 (0.24) 7.62 (0.30) 2.45 (0.10) 0.30 (0.01) 0.50 (0.02) 0.90 (0.04) Printed Front Derating - 40 - 20 0 20 40 60 80 100 100 Safe Operating Area Output Power (%) Ambient Temperature º C Free Air Convection 71º C Pin Single 1 - V Input 2 +V Input 3 -V Output 4 +V Output
www.aimtec.com Tel: +1 514 620 2722 Toll free: + 1 888 9 AIMTEC (924 6832) F 051e R11.E 3 of 3 North America only Typical Application Circuit DC DC C2 +Vout - Vin Single Output + Vin - Vin Vout C1 C2 3.3V/5V 4.7 µF 10 µF 9V/12V - 2.2 µF 15V - 1 µF Recommended EMI Circuit for Class B DC DC Cout +Vout - Vin Single Output + Vin - Vin LDM 4.7µF /25V 4.7µF /25V 6.8µH CY Vout CY Cout 3.3V/5V/9V - Refer to C2 of typical application circuit 12V/15V 1nF/4KVDC, VISHAY HGZ102MBP TDK CD45-E2GA102M-GKA NOTE: 1. Datasheets are updated as needed and as such, specifications are subject to change without notice. Once printed or downloaded, datasheets are no longer controlled by Aimtec; refer to www.aimtec.com for the most current product specifications. 2. Product labels shown, including safety agency certifications on labels, may vary based on the date manufactured. 3. Mechanical drawings and specifications are for reference only. 4. All specifications are measured at an ambient temperature of 25°C, humidi ty<75%, nominal input voltage and at rated output load unless otherwise specified. 5. Aimtec may not have conducted destructive testing or chemical analysis on all internal components and chemicals at the time of publishing this document. CAS numbers and o ther limited information are considered proprietary and may not be available for release. 6. This product is not designed for use in critical life support systems, equipment used in hazardous environments, nuclear control s ystems or other such applications which necessitate