DATASHEET SEARCH SITE | WWW.ALLDATASHEET.COM

Document overview

  • Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
  • PDF pages: 4

Technical content

1 Watt | DC-DC Converter

www.aimtec.com Tel: +1 514 620 2722 Toll free: + 1 888 9 AIMTEC (924 6832) F 051e R12.E 1 of 4 North America only FEATURES:  RoHS compliant  Operating temperature -40 oC to + 85oC  Regulated output voltage  Input / Output Isolation 1500 VDC  Low ripple and noise  Pin compatible with multiple manufacturers  High efficiency up to 81%  No Minimum Load Required  6 pin SIP package  Wide 2:1 Input Range Models Single output Model Input Voltage (VDC) Low line Input current FL (mA) Input Current FL | No Load (mA) Output Voltage (VDC) Output Current (mA) Isolation (VDC) Max Capacitive Load (uF) Efficiency (Full load) (%) AM1A-0505SZ 4.5 - 9 289 263 35 5 200 1500 1680 76 AM1A-0512SZ 4.5 - 9 278 253 35 12 83 1500 820 79 AM1A-0515SZ 4.5 - 9 275 250 35 15 67 1500 680 80 AM1A-0524SZ 4.5 - 9 275 250 35 24 42 1500 470 80 AM1A-1205SZ 9 - 18 141 107 20 5 200 1500 1680 78 AM1A-1212SZ 9 - 18 138 105 20 12 83 1500 820 80 AM1A-1215SZ 9 - 18 136 103 20 15 67 1500 680 81 AM1A-1224SZ 9 - 18 138 105 20 24 42 1500 470 80 AM1A-2405SZ 18 - 36 71 54 10 5 200 1500 1680 78 AM1A-2412SZ 18 - 36 68 52 10 12 83 1500 820 80 AM1A-2415SZ 18 - 36 69 52 10 15 67 1500 680 80 AM1A-2424SZ 18 - 36 68 52 10 24 42 1500 470 81 AM1A-4805SZ 36 - 75 36 28 7 5 200 1500 1680 76 AM1A-4812SZ 36 - 75 35 27 7 12 83 1500 820 78 AM1A-4815SZ 36 - 75 34 27 7 15 67 1500 680 78 AM1A-4824SZ 36 - 75 34 27 7 24 42 1500 470 77 FL= Full Load Models Dual output Model Input Voltage (VDC) Low line Input current FL (mA) Input Current FL | No Load (mA) Output Voltage (VDC) Output Current (mA) Isolation (VDC) Max Capacitive Load (uF) Efficiency (Full load) (%) AM1A-0512DZ 4.5 - 9 285 259 35 ±12 ±42 1500 ±470 77 AM1A-0515DZ 4.5 - 9 282 254 35 ±15 ±33 1500 ±330 79 AM1A-1212DZ 9 - 18 138 106 20 ±12 ±42 1500 ±470 79 AM1A-1215DZ 9 - 18 138 105 20 ±15 ±33 1500 ±330 80 AM1A-2412DZ 18 - 36 69 52 10 ±12 ±42 1500 ±470 80 AM1A-2415DZ 18 - 36 70 53 10 ±15 ±33 1500 ±330 79 AM1A-4812DZ 36 - 75 34 27 7 ±12 ±42 1500 ±470 77 AM1A-4815DZ 36 - 75 35 27 7 ±15 ±33 1500 ±330 77 FL= Full Load Click on Series name for product info on aimtec.com

www.aimtec.com Tel: +1 514 620 2722 Toll free: + 1 888 9 AIMTEC (924 6832) F 051e R12.E 2 of 4 North America only Input Specifications Parameters Nominal Typical Maximum Units Voltage range 4.5 – 9 9 - 18 18 - 36 36 - 75 VDC Filter Capacitor Turn on Transient process time 1 ms Start up time 50 ms Absolute Maximum Rating

5 Vin

12 Vin

15 Vin

24 Vin

Peak Input Voltage time 100 ms Input Reflected Ripple Current See application circuit 35 mA pk-pk Transient Recovery time 25% load step change 500 µs Transient Response Deviation 25% load step change ±3 % Isolation Specifications Parameters Conditions Typical Rated Units Tested I/O voltage 60 sec 1500 VDC Resistance > 1000 MOhm Capacitance 70 pF Output Specifications Parameters Conditions Typical Maximum Units Voltage accuracy ±2 % Short Circuit protection Continuous with auto recovery Line voltage regulation (Single) ±0.2 % Load voltage regulation (Single) 0% to 100% load ±1.0 % Load voltage regulation (Dual) 0% to 100% load ±2.0 % 5% to 100% load ±1.0 % Cross Regulation (Dual) 25% to 100% coupled to full load ±5 % Temperature coefficient ±0.02 %/oC Ripple & Noise* At 20MHz Bandwidth 50 mV p-p *Measured with a 1µF ceramic capacitor. General Specifications Parameters Conditions Typical Maximum Units Switching frequency 100% load 150 - 550 KHz Max Case temperature +105 oC Operating temperature Full Load without Derating -40 to +85 oC Storage temperature -55 to +125 oC Derating Not Required Cooling Free air convection Humidity 95 % Case material Non conductive black plastic Weight 3.0 g MTBF >2,800,000 hrs (MIL-HDBK -217F, Ground Benign, t=+25oC) NOTE: All specifications in this datasheet are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at rated output load unless otherwise specified

www.aimtec.com Tel: +1 514 620 2722 Toll free: + 1 888 9 AIMTEC (924 6832) F 051e R12.E 3 of 4 North America only Safety Specifications Parameters Agency Approval & Safety CE, UL UL60950-1 EN 55022: 2010+AC: 2011, Class A (external reference circuit below) EN 55024: 2010 IEC 61000-4-2: 2008 IEC 61000-4-3: 2010 IEC 61000-4-4: 2012* IEC 61000-4-5: 2005* IEC 61000-4-6: 2008 IEC 61000-4-8: 2009 *External filter capacitor for 5Vin 330µF/100V EEC & all other models 220µF/100V EEC Recommended Surge Protective Circuit Aimtec DC-DC Converter Vin+ Vin- Vo+ Vo- C1: 5V input models = 330 µF / 100V, all other models = 220 µF / 100V Recommended Circuits for Conducted Emissions Single Output Dual Output Model C1 L1 C2 5 Vin MLCC 4.7 µF / 50V 4.7 µH MLCC 220pF / 3kV 12 Vin MLCC 4.7 µF / 50V 4.7 µH MLCC 220pF / 3kV 24 Vin MLCC 4.7 µF / 50V 18 µH MLCC 220pF / 3kV 48 Vin MLCC 4.7 µF / 100V 18 µH MLCC 220pF / 3kV Input Reflected Ripple Test Circuit

www.aimtec.com Tel: +1 514 620 2722 Toll free: + 1 888 9 AIMTEC (924 6832) F 051e R12.E 4 of 4 North America only Pin Out Specifications Dimensions Pin Single Dual 1 - V Input - V Input 2 + V Input + V Input 4 + V Output + V Output

5 No pin Common

NOTE: 1. Datasheets are updated as needed and as such, specifications are subject to change without notice. Once printed or downloaded, datasheets are no longer controlled by Aimtec; refer to www.aimtec.com for the most current product specifications. 2. Product labels shown, including safety agency certifications on labels, may vary based on the date manufactured. 3. Mechanical drawings and specifications are for reference only. 4. All specifications are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at rated output load unless otherwise specified. 5. Aimtec may not have conducted destructive testing or chemical analysis on all internal components and chemicals at the time of publishing this document. CAS numbers and other limited information are considered proprietary and may not be available for release. 6. This product is not designed for use in critical life support systems, equipment used in hazardous environments, nuclear control systems or other such applications which necessitate