15 Watt | DC-DC Converter

www.aimtec.com Tel: +1 514 620 2722 Toll free: + 1 888 9 AIMTEC (924 6832) F 051e R1 1 of 5 North America only FEATURES:

  • Wide 2:1 Input Voltage Range • Operating Temperature -40ºC to +105ºC
  • High efficiency up to 91% • Output Over Voltage protection
  • 1500 VDC Isolation • Continuous Short Circuit Protection
  • Over Current Protection • Input Under Voltage Protection
  • Remote On/Off control • Bare Part Meet CISPR32/EN55032 Class A Models Single output Model Input Voltage (VDC) Output Voltage (VDC) Input Current max Full/No Load (mA) Output Current max (mA) Isolation (VDC) Max Capacitive Load (uF) Efficiency Typ. (%) AM15C-1203S-NZ 9-18 3.3 1280/65 4000 1500 4700 88 AM15C-1205S-NZ 9-18 5 1421/65 3000 1500 4700 90 AM15C-1212S-NZ 9-18 12 1421/22 1250 1500 1000 90 AM15C-1215S-NZ 9-18 15 1405/22 1000 1500 820 91 AM15C-1224S-NZ 9-18 24 1405/22 625 1500 270 91 AM15C-2403S-NZ 18-36 3.3 647/50 4000 1500 4700 88 AM15C-2405S-NZ 18-36 5 711/50 3000 1500 4700 90 AM15C-2412S-NZ 18-36 12 711/15 1250 1500 1000 90 AM15C-2415S-NZ 18-36 15 703/15 1000 1500 820 91 AM15C-2424S-NZ 18-36 24 703/20 625 1500 270 91 AM15C-4803S-NZ 36-75 3.3 320/30 4000 1500 4700 88 AM15C-4805S-NZ 36-75 5 356/30 3000 1500 4700 90 AM15C-4812S-NZ 36-75 12 352/11 1250 1500 1000 91 AM15C-4815S-NZ 36-75 15 352/11 1000 1500 820 91 AM15C-4824S-NZ 36-75 24 352/11 625 1500 270 91 NOTE: All specifications in this datasheet are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at rated output load unless otherwise specified. Input Specifications Parameters Nominal Typical Maximum Units Voltage range

12 Vin 9-18

48 Vin 36-75

Absolute Maximum Rating (1s) 12 Vin -0.7 – 25 VDC 24 Vin -0.7 – 50 48 Vin -0.7 - 100 Input reflected ripple current 30 mA Input Under voltage protection 12 Vin 6.5 VDC 24 Vin 15.5

48 Vin 30

Startup time Nominal input, resistive load 10 ms Remote On/Off Control On Off 3.5-12VDC or leave open 0-1.2VDC or connect to GND, idle current 2-7mA Isolation Specifications Parameters Conditions Typical Maximum Units Tested I/O voltage 60 sec, <1mA 1500 VDC Resistance 500VDC >1000 MOhm Capacitance I/O, 100KHz/0.1V 2000 pF Picture coming soon

www.aimtec.com Tel: +1 514 620 2722 Toll free: + 1 888 9 AIMTEC (924 6832) F 051e R1 2 of 5 North America only Output Specifications Parameters Conditions Typical Maximum Units Voltage accuracy 0% to 100% load ±1 ±3 % Over voltage protection 110-160 % of Vout Over current protection 110-190 % of Iout Short Circuit protection Continuous Short circuit restart Auto-Recovery Line voltage regulation Full load, LL to HL ±0.2 ±0.5 % of Vin Load voltage regulation 5% to 100% load ±0.5 ±1 % Temperature coefficient 100% load ±0.03 %/oC Ripple & Noise 20MHz Bandwidth, 5-100% load 50 100 mV p-p Transient recovery time 25% load step change 0.3 0.5 ms Transient recovery deviation 25% load step change 3.3/5V output ±3 ±7 % Others ±3 ±5 General Specifications Parameters Conditions Typical Maximum Units Switching frequency 100% load 3.3/5V output 300 KHz Others 270 Operating temperature See derating curve 3.3/5V output -40 to +95 oC Others -40 to +105 Storage temperature -55 to +125 oC Maximum case temperature 105 oC Cooling Free air convection Humidity 95 % RH Case material Aluminum Alloy Weight 15 g Dimensions (L x W x H) 1 x 1 x 0.46 inches 25.40 x 25.40 x 11.70 mm MTBF >1,000,000 hours (MIL-HDBK -217F, Ground Benign, t=+25 o Maximum soldering temperature 1.5mm from case for 10 sec 300 oC Safety Specifications Parameters Standards Designed to meet EN62368 CISPR32 / EN 55032, Class A, Class B with the recommended EMC circuit Electrostatic Discharge Immunity IEC 61000-4-2, Contact ±6KV, Air ±8KV, Criteria B RF, Electromagnetic Field Immunity IEC 61000-4-3, 10V/m, Criteria A Electrical Fast Transient / Burst Immunity IEC 61000-4-4, ±2KV with the recommended EMC circuit, Criteria A Surge Immunity IEC 61000-4-5, L-L ±2KV with the recommended EMC circuit, Criteria B RF, Conducted Disturbance Immunity IEC 61000-4-6, 3 Vrms, Criteria A Pin Out Specifications Pin Single 1 +V Input 2 -V Input

3 On/Off Control

5 Trim

www.aimtec.com Tel: +1 514 620 2722 Toll free: + 1 888 9 AIMTEC (924 6832) F 051e R1 3 of 5 North America only Dimensions 25.40 (1.00) 2.54 (0.10) 20.32 (0.80) 2.54 (0.10) 10.16 (0.40) 5.08 (0.20) 7.62 (0.30) 2.54 (0.10)10.16 (0.40) 10.16 (0.40) 25.40 (1.00) 9.90 (0.39) Printed Face 1.00 (0.39) Top View Side View 2.54 (0.10) Input Input CTRL 4 5 6 +V Output -V Output Bottom View Trim Derating - 40 - 20 0 20 40 60 80 100 100 Safe Operating Area Output Power (%) Ambient Temperature º C Free Air Convection 12V/15V/24V Output 3.3V/5V Output 75 105 Typical Application Circuits DC DC +Vout - Vout + Vin - Vin + Vout - Vout 100uF + Vin - Vin Model 3.3V/5V/12V/15V Vout 24V Vout C2 100µF 47µF Case Tolerance ±0.50 (±0.02) Pin Diameter 1.0 ± 0.10 (0.04 ± 0.004) Dimensions mm (inch)

www.aimtec.com Tel: +1 514 620 2722 Toll free: + 1 888 9 AIMTEC (924 6832) F 051e R1 4 of 5 North America only Recommended EMC Circuits DC DC +Vout - Vout CY2 1nF/2KV + Vin - Vin + Vout - Vout CY1 1nF/2KV + Vin - Vin LDM FUSE C2 C5 Model 12V/24V Vin 48V Vin FUSE Choose based on actual input current C1, C4 330µF/50V 330µF/100V C2, C3 4.7µF/50V 4.7µF/100V LDM 2.2µh/4A 2.2µH/2A C5 Refer to the C2 in typical application circuit Trimming Output voltage can be externally trimmed by utilizing the methods as shown below Fixed Resistor Variable Potentiometer Leave open if not used. 3.3V output models Trim down % 1 2 3 4 5 6 7 8 9 10 Trim up % 1 2 3 4 5 6 7 8 9 10

www.aimtec.com Tel: +1 514 620 2722 Toll free: + 1 888 9 AIMTEC (924 6832) F 051e R1 5 of 5 North America only 5V output models Trim down % 1 2 3 4 5 6 7 8 9 10 Trim up % 1 2 3 4 5 6 7 8 9 10 12V output models Trim down % 1 2 3 4 5 6 7 8 9 10 Trim up % 1 2 3 4 5 6 7 8 9 10 15V output models Trim down % 1 2 3 4 5 6 7 8 9 10 Trim up % 1 2 3 4 5 6 7 8 9 10 24V output models Trim down % 1 2 3 4 5 6 7 8 9 10 Trim up % 1 2 3 4 5 6 7 8 9 10 NOTE: 1. Datasheets are updated as needed and as such, specifications are subject to change without notice. Once printed or downloaded, datasheets are no longer controlled by Aimtec; refer to www.aimtec.com for the most current product specifications. 2. Product labels shown, including safety agency certifications on labels, may vary based on the date manufactured. 3. Mechanical drawings and specifications are for reference only. 4. All specifications are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at rated output load unless otherwise specified. 5. Aimtec may not have conducted destructive testing or chemical analysis on all internal components and chemicals at the time of publishing this document. CAS numbers and other limited information are considered proprietary and may not be available for release. 6. This product is not designed for use in critical life support systems, equipment used in hazardous environments, nuclear control systems or other such applications which necessitate