AM150HB-UZ AIMTEC | Alldatasheet
Document overview
- Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
- PDF pages: 4
Technical content
150 Watt | Half Brick DC-DC Converter
www.aimtec.com Tel: +1 514 620 2722 Toll free: + 1 888 9 AIMTEC (924 6832) F 054e R3.F 1 of 4 North America only FEATURES: Models Single output Model Input Voltage (V) Output Voltage (V) Output Current max (A) Input Filter AM150HB-2403S-UZ 18-36 3.3 30 π type AM150HB-2405S-UZ 18-36 5 30 π type AM150HB-2412S-UZ 18-36 12 12.5 L type AM150HB-2415S-UZ 18-36 15 10 L type AM150HB-2424S-UZ 18-36 24 6.3 L type AM150HB-2428S-UZ 18-36 28 5.4 L type AM150HB-2448S-UZ 18-36 48 3.1 L type AM150HB-4803S-UZ 36-72 3.3 30 π type AM150HB-4805S-UZ 36-72 5 30 π type AM150HB-4812S-UZ 36-72 12 12.5 L type AM150HB-4815S-UZ 36-72 15 10 L type AM150HB-4824S-UZ 36-72 24 6.3 L type AM150HB-4828S-UZ 36-72 28 5.4 L type AM150HB-4848S-UZ 36-72 48 3.1 L type AM150HB-11005S-UZ 66-160 5 30 π type AM150HB-11012S-UZ 66-160 12 12.5 L type AM150HB-11015S-UZ 66-160 15 10 L type AM150HB-11024S-UZ 66-160 24 6.3 L type NOTE: All specifications are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at rated output load unless otherwise specified. Input Specifications Parameters Nominal Typical Maximum Units Voltage range 110 18-36 36-72 66-160 VDC Remote Control CNTRL open or connect to +Vin CNTRL connect to –Vin On Off Logic Low 0.4 V Turn On Time 10 ms Start-up Delay Time 150 ms Isolation Specifications Parameters Conditions Typical Maximum Units Tested I/O voltage 1 Min 1500 VDC Tested Input / Case voltage 1 Min 500 VDC Tested Output / Case voltage 1 Min 500 VDC Output Specifications Parameters Conditions Typical Maximum Units Set point accuracy ±1 % Trim range ±10 % Dynamic Response 200µs setting time 50-75% & 50-25% load 3% of Vout Pk deviation Short Circuit protection Continuous Short Circuit restart Auto recovery
- RoHS compliant • Regulated output
- Wide 2:1 Input range • High efficiency
- Very low ripple and noise • Operating temperature range: -40 to +85ºC
- On/Off Control and Trim Function • 1500VDC I/O Isolation
www.aimtec.com Tel: +1 514 620 2722 Toll free: + 1 888 9 AIMTEC (924 6832) F 054e R3.F 2 of 4 North America only Output Specifications (continued) Parameters Conditions Typical Maximum Units Over Temperature Protection >105 110 115 oC Total remote sense compensation 0.5 V Line voltage regulation ±0.2 % of Vin Load voltage regulation ±0.5 % Temperature coefficient ±0.02 %/oC Ripple & Noise 20MHz Bandwidth 1 % of Vout Maximum Capacitor Load >10,000 μF General Specifications Parameters Conditions Typical Maximum Units Switching frequency 100% load 280 KHz Efficiency At full load 85 ~ 87 % Soldering Temperature Wave solder <10s 250 oC Hand Soldering time Iron Temperature: 425 oC 5 sec Operating temperature -40 to +85 oC Storage temperature -55 to +125 oC Max case temperature 100 oC Cooling See derating graph Humidity 10 to 90 % Weight Without heatsink 75 g MTBF >2,000,000 hrs (Bellcore TR332, t=+25oC) Safety Specifications Standards Safety Meets EN60950 Pin Out Specifications Dimensions Pin Single 1 -V Input
2 Case
3 On/Off Control
7 Trim
10 Omitted
www.aimtec.com Tel: +1 514 620 2722 Toll free: + 1 888 9 AIMTEC (924 6832) F 054e R3.F 3 of 4 North America only Derating: 02 0 4 0 60 80 100 Safe Operating Area Output Power (%) Ambient Temperature º C A B C D 100 E A Free Air B
100 LFM
C
200 LFM
D
300 LFM
E
400 LFM
Typical Application: Aimtec’s half brick models can operate independently. However, to enhance their performance and to ensure precision of the output signal parameters the following connections are recommended: Output Ripple and Noise Measurement test setup: Please refer to our Application note: Ripple and Noise Measurement of Brick & POL DC-DC Converters. ON/OFF Control: The converter output can be disabled by moving SW to position “a“– connected to –Vin with voltage level between -0.7 and 0.4V. When SW is open in position “b”, the converter is ON and operates normally.
www.aimtec.com Tel: +1 514 620 2722 Toll free: + 1 888 9 AIMTEC (924 6832) F 054e R3.F 4 of 4 North America only The SW can be replaced by a NPN transistor with connection as follows: Output Voltage Trim connection: The output voltage can be adjusted by connecting trim resistors as shown. The values can be determined according to the following formulas where Δ% is the desirable voltage adjustment in percentage and Vo is the Nominal value of the Output Voltage: The calculated Resistor values are in KΩ. NOTE: 1. Datasheets are updated as needed and as such, specifications are subject to change without notice. Once printed or downloaded, datasheets are no longer controlled by Aimtec; refer to www.aimtec.com for the most current product specifications. 2. Product labels shown, including safety agency certifications on labels, may vary based on the date manufactured. 3. Mechanical drawings and specifications are for reference only. 4. Aimtec may not have conducted destructive testing or chemical analysis on all internal components and chemicals at the time of publishing this document. CAS numbers and other limited information are considered pro prietary and may not be available for release. 5. This product is not designed for use in critical life support sy stems, equipment used in hazar dous environments, nuclear contr ol systems or other such applications which necessitate specific safety and regulatory standards other the ones listed in this datasheet. 1.225∆% ∆% KΩ Rup = 100 – 2 ∆% KΩ Rdown =