AM12T-Z AIMTEC | Alldatasheet

Document overview

  • Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
  • PDF pages: 3

Technical content

12 Watt | DC-DC Converter

www.aimtec.com Tel: +1 514 620 2722 Toll free: + 1 888 9 AIMTEC (924 6832) F 051e R12.F 1 of 3 North America only FEATURES:  Wide Input Range 2:1  No Minimum Load Required  1600 Vdc Isolation  -40ºC to +85ºC Operating Temperature Range  Efficiency up to 91%  Short Circuit & Over Voltage Protection  Soft Start  DIP 24 Package  Remote On/Off Function  Low No Load Input Current Models Single output Model Input Voltage (V) Output Voltage (V) Output Current max (mA) Isolation (VDC) Maximum Capacitive load (µF) Efficiency (%) AM12T-1202SZ 9-18 2.5 3500 1600 2000 85 AM12T-1203SZ 9-18 3.3 3500 1600 2000 87 AM12T-1205SZ 9-18 5 2400 1600 2000 89 AM12T-1212SZ 9-18 12 1000 1600 430 90 AM12T-1215SZ 9-18 15 800 1600 300 90 AM12T-2402SZ 18-36 2.5 3500 1600 2000 85 AM12T-2403SZ 18-36 3.3 3500 1600 2000 87 AM12T-2405SZ 18-36 5 2400 1600 2000 89 AM12T-2412SZ 18-36 12 1000 1600 430 90 AM12T-2415SZ 18-36 15 800 1600 300 90 AM12T-4802SZ 36-75 2.5 3500 1600 2000 84 AM12T-4803SZ 36-75 3.3 3500 1600 2000 88 AM12T-4805SZ 36-75 5 2400 1600 2000 89 AM12T-4812SZ 36-75 12 1000 1600 430 88 AM12T-4815SZ 36-75 15 800 1600 300 89 Models Dual output Model Input Voltage (V) Output Voltage (V) Output Current max (mA) Isolation (VDC) Maximum Capacitive load (µF) Efficiency (%) AM12T-1212DZ 9-18 ±12 ±500 1600 ±200 90 AM12T-1215DZ 9-18 ±15 ±400 1600 ±120 91 AM12T-2412DZ 18-36 ±12 ±500 1600 ±200 90 AM12T-2415DZ 18-36 ±15 ±400 1600 ±120 91 AM12T-4812DZ 36-75 ±12 ±500 1600 ±200 88 AM12T-4815DZ 36-75 ±15 ±400 1600 ±120 89 NOTE: All specifications in this datasheet are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at rated output load unless otherwise specified Input Specifications Parameters Nominal Typical Maximum Units Voltage range 12 9-18 VDC 24 18-36 48 36-48 Filter π (Pi) Network Turn on Transient process time 250 µs Transient response deviation ±3 % Start up time Nominal Vin and constant resistive load 20 ms Absolute Maximum Rating 12 Vin models -0.7-36 VDC 24 Vin models -0.7-50 48 Vin models -0.7-100

www.aimtec.com Tel: +1 514 620 2722 Toll free: + 1 888 9 AIMTEC (924 6832) F 051e R12.F 2 of 3 North America only Input Specifications (continued) Parameters Nominal Typical Maximum Units Peak Input Voltage time 1000 ms Input reflected ripple current 20 mA p-p Quiescent Current 15 mA On/Off Control ON – High (3.0 ... 12Vdc) or open circuit; OFF – Low (0 ... 1.2Vdc) or Short circuit pin1 and pin 2/3 OFF idle current: 5.0 mA typ Isolation Specifications Parameters Conditions Typical Rated Units Tested I/O voltage 3 sec 1600 VDC Tested Case/Input and Output 1600 VDC Resistance >1000 MOhm Capacitance 1200 pF Output Specifications Parameters Conditions Typical Maximum Units Voltage accuracy ±1.2 % Voltage balance Dual output ±5 % Line voltage regulation HL-LL ±0.5 % Load voltage regulation (Single) 0% Load to Full Load ±0.5 % Load voltage regulation (Dual) 0% Load to Full Load ±1.0 % Over voltage protection Zener diode clamp Over current protection Full Load 150 % Short Circuit protection Continuous Short circuit restart Auto recovery Ripple & Noise 85 m Vp-p General Specifications Parameters Conditions Typical Maximum Units Switching frequency 100% load 330 KHz Operating temperature Full Load with Derating above 60ºC -40 to +85 oC Storage temperature -40 to +125 oC Max Case temperature 100 oC Temperature coefficient ±0.02 %/ oC Derating Above 60ºC 2.5 % per 1ºC Cooling Free air convection Humidity 95 % RH Case material Nickel-coated Copper Potting material UL94V-0 rated Weight 18.0 g MTBF >1 000 000 hrs (MIL-HDBK -217F, Ground Benign, t=+25 oC) Safety Specifications Parameters Agency Approval CE Standards IEC 60950-1:2005 (2nd Edition); EN 60950-1: 2006 EN55022 Class A, EN55024 IEC61000-4-2, Perf. Criteria B IEC61000-4-3, Perf. Criteria A IEC61000-4-4, Perf. Criteria B (external 330uF/100V cap required) IEC61000-4-5, Perf. Criteria B (external 330uF/100V cap required) IEC61000-4-6, Perf. Criteria A IEC61000-4-8, Perf. Criteria A

www.aimtec.com Tel: +1 514 620 2722 Toll free: + 1 888 9 AIMTEC (924 6832) F 051e R12.F 3 of 3 North America only Pin Out Specifications Derating Pin Single Dual

1 Remote On/Off Remote On/Off

9 No Pin Common

11 N.C. -V Output 14 +V Output +V Output 16 -V Output Common 22 +V Input +V Input 23 +V Input +V Input Dimensions Test Circuits NOTE: 1. Datasheets are updated as needed and as such, specifications are subject to change without notice. Once printed or downloaded, datasheets are no longer controlled by Aimtec; refer to www.aimtec.com for the most current product specifications. 2. Product labels shown, including safety agency certifications on labels, may vary based on the date manufactured. 3. Mechanical drawings and specifications are for reference only. 4. All specifications are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at rated output load unless otherwise specified. 5. Aimtec may not have conducted destructive testing or chemical analysis on all internal components and chemicals at the time of publishing this document. CAS numbers and other limited information are considered proprietary and may not be available for release. 6. This product is not designed for use in critical life support systems, equipment used in hazardous environments, nuclear control systems or other such applications which necessitate Surge: DC/DC Converter +Vout -Vout Load +Vin -Vin 330uF, 100V DC/DC Converter +Vout -Vout Load +Vin -Vin 100uF, 100V L 12uH Conducted Emmisions :