AM10C-NZ AIMTEC | Alldatasheet
Document overview
- Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
- PDF pages: 4
Technical content
10 Watt | DC-DC Converter
www.aimtec.com Tel: +1 514 620 2722 Toll free: + 1 888 9 AIMTEC (924 6832) F 051e R2 1 of 4 North America only Picture coming soon FEATURES:
- Wide 2:1 Input Voltage Range • Operating Temperature -40ºC to +85ºC
- High efficiency up to 88% • Output Over Voltage protection
- 1500 VDC Isolation • Continuous Short Circuit Protection
- Over Current Protection • Input Under Voltage Protection
- No load consumption ≤ 0.12W • Remote On/Off control Models Single output Model Input Voltage (V) Output Voltage (V) Output Current max (A) Isolation (VDC) Max Capacitive Load (uF) Efficiency (%) AM10C-2405S-NZ 18-36 5 2 1500 2200 83 AM10C-2412S-NZ 18-36 12 0.83 1500 470 87 AM10C-2415S-NZ 18-36 15 0.66 1500 330 88 AM10C-2424S-NZ 18-36 24 0.41 1500 100 88 *Add suffix “-ST” for optional screw terminal bottom plate **Add suffix “-STD” for optional DIN Rail screw terminal bottom plate NOTE: All specifications in this datasheet are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at rated output load unless otherwise specified. Input Specifications Parameters Nominal Typical Maximum Units Voltage range 24 Vin 18-36 VDC Filter Pi Absolute Maximum Rating (1s) 24 Vin -0.7 - 50 VDC No Load Input Current 24 Vin 12 mA Input reflected ripple current 24 Vin 40 mA Input Under voltage protection 24 Vin 15.5 VDC Startup time Nominal input, resistive load 10 ms Remote On/Off Control On Off 3.5-12VDC or leave open 0-1.2VDC or connect to GND, idle current 6-10mA Isolation Specifications Parameters Conditions Typical Maximum Units Tested I/O voltage 60 sec, <1mA 1500 VDC Resistance 500VDC >1000 MOhm Capacitance I/O, 100KHz/0.1V 1000 pF Output Specifications Parameters Conditions Typical Maximum Units Voltage accuracy 5% to 100% load ±1 ±3 % Over voltage protection 110-160 % of Vout Over current protection 110-190 % of Iout Short Circuit protection Continuous Short circuit restart Auto-Recovery Line voltage regulation Full load, LL to HL ±0.5 % of Vin Load voltage regulation 5% to 100% load ±1 % Temperature coefficient 100% load ±0.03 %/oC Ripple & Noise 20MHz Bandwidth, 5-100% load 100 mV p-p Transient recovery time 25% load step change 500 µs Transient recovery deviation 25% load step change ±5 %
www.aimtec.com Tel: +1 514 620 2722 Toll free: + 1 888 9 AIMTEC (924 6832) F 051e R2 2 of 4 North America only General Specifications Parameters Conditions Typical Maximum Units Switching frequency 100% load 350 KHz Operating temperature See derating curve -40 to +85 oC Storage temperature -55 to +125 oC Maximum case temperature 100 oC Cooling Free air convection Humidity 95 % RH Case material Aluminum Alloy Weight Pin mountable 15 g With optional -ST mounting plate: 35 With optional -STD mounting plate: 55 Dimensions (L x W x H) Pin mountable 1 x 1 x 0.46 inches 25.40 x 25.40 x 11.70 mm MTBF >1,000,000 hours (MIL-HDBK -217F, Ground Benign, t=+25 o Maximum soldering temperature 1.5mm from case for 10 sec 300 oC Environmental Specifications Parameters Vibration Test mode 10-55Hz Acceleration 10G, 30min one cycle, every axis tested Safety Specifications Parameters Standards Designed to meet IEC/EN/UL60950-1 EN 55022, class B (with the recommended EMC circuit) Electrostatic Discharge Immunity IEC 61000-4-2, Contact ±4KV, Criteria B RF, Electromagnetic Field Immunity IEC 61000-4-3, 10V/m, Criteria A Electrical Fast Transient / Burst Immunity IEC 61000-4-4, ±2KV, Criteria B (with the recommended EMC circuit) Surge Immunity IEC 61000-4-5, ±2KV, Criteria B (with the recommended EMC circuit) RF, Conducted Disturbance Immunity IEC 61000-4-6, 3 Vrms, Criteria A Voltage dips, Short Interruptions & Voltage variations Immunity IEC 61000-4-29: 0-70%, Criteria B Dimensions Pin Out Specifications Pin Single 1 +V Input 2 -V Input
3 On/Off Control
5 No pin
25.40 (1.00) 2.54 (0.10) 20.32 (0.80) 2.54 (0.10) 10.16 (0.40) 5.08 (0.20) 7.62 (0.30) 2.54 (0.10)10.16 (0.40) 10.16 (0.40) 25.40 (1.00)11.70 (0.46) Printed Face ᴓ 1.00 (0.39) Top View Side View 2.54 (0.10) Input Input CTRL 4 5 6 +V Output -V Output Bottom View 4.10 (0.16) Case Tolerance ±0.50 (±0.02) Pin Diameter 1.0 ± 0.10 (0.04 ± 0.004) Dimensions mm (inch)
www.aimtec.com Tel: +1 514 620 2722 Toll free: + 1 888 9 AIMTEC (924 6832) F 051e R2 3 of 4 North America only Screw Terminal Option: AM10C-NZ-ST Front View Top View 76.00 (2.99) 61.60 (2.43) 31.50 (1.24) 23.00 (0.91) 21.20 (0.84) 8.80 (0.35) LED lampØ3.30 Ø3.30 DIN-RAIL Option: AM10C-NZ-STD Front View Top View 76.00 (2.99) 61.60 (2.43) 31.50 (1.24) 23.00 (0.91) 25.80 (1.02) 22.20 (0.87) 9.80 (0.39) LED lamp Pin Single Dual
1 NC NC
5 NC Common
Note: Unit: mm (inch) Wire range: 24-12 AWG Tightening torque: Max 0.4 N*m General tolerances: ±0.50 (±0.02) Note: Unit: mm (inch) Mounting rail: TS35 Wire range: 24-12 AWG Tightening torque: Max 0.4 N*m General tolerances: ±0.50 (±0.02)
www.aimtec.com Tel: +1 514 620 2722 Toll free: + 1 888 9 AIMTEC (924 6832) F 051e R2 4 of 4 North America only Derating Recommended EMC Circuits DC-DC Converter +Vin -Vin +Vo -Vo CY1 1nF/2KV CY2 1nF/2KV C1 C3 MOV LCM 4.7mH 24V input MOV S20K30 C1 680µF/50V C2 1µF/50V C3 330µF/50V C4 4.7µF/50V C5 10µF/50V NOTE: 1. Datasheets are updated as needed and as such, specifications are subject to change without notice. Once printed or downloaded, datasheets are no longer controlled by Aimtec; refer to www.aimtec.com for the most current product specifications. 2. Product labels shown, including safety agency certifications on labels, may vary based on the date manufactured. 3. Mechanical drawings and specifications are for reference only. 4. All specifications are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at rated output load unless otherwise specified. 5. Aimtec may not have conducted destructive testing or chemical analysis on all internal components and chemicals at the time of publishing this document. CAS numbers and other limited information are considered proprietary a nd may not be available for release. 6. This product is not designed for use in critical life support systems, equipment used in hazardous environments, nuclear control s ystems or other such applications which necessitate - 40 - 20 0 20 40 60 80 100 100 Safe Operating Area Output Power (%) Ambient Temperature º C Free Air Convection 71º C Other models 65º C 5V model 7165