DATASHEET SEARCH SITE | WWW.ALLDATASHEET.COM

Document overview

  • Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
  • PDF pages: 3

Technical content

10 Watt | DC-DC Converter

www.aimtec.com Tel: +1 514 620 2722 Toll free: + 1 888 9 AIMTEC (924 6832) F 051e R13 1 of 3 North America only Picture coming soon FEATURES:  Wide 2:1 Input Voltage Range  1500 VDC Isolation  High Efficiency up to 89%  Operating Temperature -40ºC to +85ºC  Remote On/Off  Over Voltage, Over load protection  Standard 1”x1” Package  Output Short Circuit Protection Models Single output Model Input Voltage (V) Output Voltage (V) Output Current max (mA) Max Capacitive Load(uF) Efficiency (%) AM10C-1203S-FZ 9-18 3.3 2200 3300 83 AM10C-1205S-FZ 9-18 5 2000 2200 86 AM10C-1212S-FZ 9-18 12 830 680 89 AM10C-1215S-FZ 9-18 15 660 330 88 AM10C-1224S-FZ 9-18 24 410 100 88 AM10C-2403S-FZ 18-36 3.3 2200 3300 82 AM10C-2405S-FZ 18-36 5 2000 2200 86 AM10C-2412S-FZ 18-36 12 830 680 88 AM10C-2415S-FZ 18-36 15 660 330 87 AM10C-2424S-FZ 18-36 24 410 100 87 AM10C-4803S-FZ 36-75 3.3 2200 3300 80 AM10C-4805S-FZ 36-75 5 2000 2200 84 AM10C-4812S-FZ 36-75 12 830 680 86 AM10C-4815S-FZ 36-75 15 660 330 85 AM10C-4824S-FZ 36-75 24 410 100 85 Models Dual output Model Input Voltage (V) Output Voltage (V) Output Current max (mA) Max Capacitive Load(uF) Efficiency (%) AM10C-1205D-FZ 9-18 ±5 ±1000 ±1000 86 AM10C-1212D-FZ 9-18 ±12 ±410 ±470 89 AM10C-1215D-FZ 9-18 ±15 ±330 ±220 88 AM10C-2405D-FZ 18-36 ±5 ±1000 ±1000 85 AM10C-2412D-FZ 18-36 ±12 ±410 ±470 88 AM10C-2415D-FZ 18-36 ±15 ±330 ±220 87 AM10C-4805D-FZ 36-75 ±5 ±1000 ±1000 84 AM10C-4812D-FZ 36-75 ±12 ±410 ±470 86 AM10C-4815D-FZ 36-75 ±15 ±330 ±220 85 NOTE: All specifications in this datasheet are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at rated output load unless otherwise specified. Input Specifications Parameters Nominal Typical Maximum Units Voltage range 12 9-18 VDC 24 18-36 48 36-75 Filter Pi Start up time 100 ms Absolute Maximum Rating

12 Vin 25

48 Vin 100

Peak Input Voltage time 100 ms On/Off control ON –Open or 3.5 to 12V/<0.2mA OFF –Short to pin 2 (-Vin) or 0 to 0.7V

www.aimtec.com Tel: +1 514 620 2722 Toll free: + 1 888 9 AIMTEC (924 6832) F 051e R13 2 of 3 North America only Input Specifications (continued) Parameters Nominal Typical Maximum Units Idle input Current At OFF state 12 mA Input reflected current Nominal Vin and full load 53 mA p-p Transient response settling time 50% load step change 1.3 ms Transient response deviation di/dt=0.8A/µs ≤5 % 3.3Vou ≤6 Isolation Specifications Parameters Conditions Typical Maximum Units Tested I/O voltage 1500 VDC Resistance 500VDC >1000 MOhm Capacitance 1100 pF Output Specifications Parameters Conditions Typical Maximum Units Voltage accuracy ±1 % Over voltage protection

3.3 Vout

5 Vout

12 Vout

15 Vout

24 Vout

3.9 6.2 V Short Circuit protection Continuous Short circuit restart Auto-Recovery Line voltage regulation LL to HL at full load ±1 % of Vin Load voltage regulation (Single) 1% to 100% load ±1 % Load voltage regulation (Dual) Balanced Load ±0.5 % Unbalanced load 25% to 100% load ±5 % Temperature coefficient ±0.02 %/ oC Ripple & Noise 20MHz Bandwidth 80 mV p-p General Specifications Parameters Conditions Typical Maximum Units Switching frequency 100% load 330 KHz Operating temperature With derating above 60°C -40 to +85 oC Storage temperature -55 to +125 oC Maximum case temperature 105 oC Cooling Natural convection Humidity 95 % RH Case material Nickel-coated copper Weight 17.4 g Dimensions (L x W x H) 1 x 1 x 0.4 inches 25.4 x 25.4 x 10.2 mm MTBF >1,580,000 hrs (MIL-HDBK -217F, Ground Benign, t=+25°C) Pin Out Specifications Pin Single Dual 1 +V input +V input 2 -V Input -V Input

3 On/Off Control On/Off Control

5 No Pin Common

www.aimtec.com Tel: +1 514 620 2722 Toll free: + 1 888 9 AIMTEC (924 6832) F 051e R13 3 of 3 North America only Dimensions Notes: All dimensions are typical in millimeters (inches). Pin Pitch Tolerance ±0.35 (±0.014) Case Tolerance ±0.50 (±0.02) Derating -4 0 -2 0 02 0 4 0 6 0 80 100 100 Safe Operating Area Output Power (%) Ambient Temperature º C Free Air Convection 60º C NOTE: 1. Datasheets are updated as needed and as such, specifications are subject to change without notice. Once printed or downloaded, datasheets are no longer controlled by Aimtec; refer to www.aimtec.com for the most current product specifications. 2. Product labels shown, including safety agency certifications on labels, may vary based on the date manufactured. 3. Mechanical drawings and specifications are for reference only. 4. All specifications are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at rated output load unless otherwise specified. 5.Aimtec may not have conducted destructive testing or chemical analysis on all internal components and chemicals at the time of publishing this document. CAS numbers and other limited information are considered proprietary and may not be available for release. 6. This product is not designed for use in critical life support systems, equipment used in hazardous environments, nuclear control systems or other such applications which necessitate 25.40 (1.00) 2.54 (0.10) 20.32 (0.80) 2.54 (0.10) 10.16 (0.40) 5.08 (0.20) 7.62 (0.30) 2.54 (0.10)10.16 (0.40) 10.16 (0.40) 25.40 (1.00)9.90 (0.39) Printed Face 1.00 (0.39) Top View Side View 2.54 (0.10) Input Input CTRL 4 56 +V Output -V Output Bottom View