AM100QB-NZ AIMTEC | Alldatasheet

Document overview

  • Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
  • PDF pages: 13

Technical content

100 Watt | DC-DC Converter

www.aimtec.com Tel: +1 514 620 2722 Toll free: + 1 888 9 AIMTEC (924 6832) F 051e R1 1 of 13 North America only FEATURES:

  • Wide Input Range up to160V • Meet Railway Standard: EN50155
  • Low no-load Power • Industry Standard: 1/4 Brick
  • Efficiency up to 93% • Operating temperature -40°C to + 100°C
  • Up to 3000VDC I/O Isolation
  • Remote ON/OFF Control
  • Over Current, Over Voltage, Over Temperature & Continuous Short Circuit Protection Models Single output Model Input Voltage (VDC) Input Current No load/Full load (mA) Output Voltage (VDC) Output Current max (A) Max Capacitive load (µF) Efficiency (%) AM100QB-2405SH22-NZ 24 (9-36) 160/4789 5 20 6000 89 AM100QB-2412SH22-NZ 24 (9-36) 160/4789 12 8.3 2000 90 AM100QB-2415SH22-NZ 24 (9-36) 160/4789 15 6.7 2000 90 AM100QB-2424SH22-NZ 24 (9-36) 160/4789 24 4.2 1000 90 AM100QB-2428SH22-NZ 24 (9-36) 160/4789 28 3.6 1000 90 AM100QB-2448SH22-NZ 24 (9-36) 160/4789 48 2.1 470 90 AM100QB-4805SH22-NZ 48 (18-75) 80/2341 5 20 6000 91 AM100QB-4812SH22-NZ 48 (18-75) 80/2341 12 8.3 2000 92 AM100QB-4815SH22-NZ 48 (18-75) 80/2341 15 6.7 2000 93 AM100QB-4824SH22-NZ 48 (18-75) 80/2341 24 4.2 1000 92 AM100QB-4848SH22-NZ 48 (18-75) 80/2341 48 2.1 470 92 AM100QB-11012S-NZ 110 (66-160) 15/1044 12 8.333 6,000 89 AM100QB-11015S-NZ 110 (66-160) 15/1044 15 6.667 4,700 89 AM100QB-11024S-NZ 110 (66-160) 15/1010 24 4.167 3,000 92 *Add suffix “-K” on nominal input 24V and 110V models only for optional heatsink **Add suffix “-M” on nominal input 24V and 48V models only for optional aluminum alloy bottom case NOTE: All specifications in this datasheet are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at rated output load unless otherwise specified. Input Specifications Parameters Nominal Typical Maximum Units Voltage range 24V models 9-36 40 VDC 48V models 18-75 80 110V models 66-160 170 Filter π(Pi) Network Startup time 25 ms Absolute Maximum Rating 24V models 50 VDC 48V models 90 110V models 180 Peak Input Voltage time 1,000 ms Input reflected ripple current 24V models 30 mA p-p 48V models 30 110V models 50 Under Voltage Lockout (On/Off) 24V models 7.5 VDC 48V models, 5V/15V output 16.5 48V models, others 15.5 110V models 58 Remote On / OFF Control ON: 3.5 ~ 12Vdc or Open Circuit OFF: 0 ~ 1.2Vdc or Ctrl connected to -Vin Idle current: 2~65mA for 24V models, 2-10mA for 48V &110V models VDC Click on Series name for product info on aimtec.com

www.aimtec.com Tel: +1 514 620 2722 Toll free: + 1 888 9 AIMTEC (924 6832) F 051e R1 2 of 13 North America only Isolation Specifications Parameters Conditions Typical Rated Units Tested I/O voltage 24V & 48V models, 60s 2250 VDC 110V models, 60s 3000 Input to Case 24V models, 60s 1600 VDC 48V/110V models, 60s 1500 Output to Case 24V/48V models, 60s 500 VDC 110V models, 60s 1500 Resistance >1000 MOhm Capacitance 2200 pF Output Specifications Parameters Conditions Typical Maximum Units Voltage accuracy 24V & 48V models ±1 ±3 % 110V models ±2 Over voltage protection Zener Diode Clamp Over load protection 24V models 110~150 % of Iout 48V models 110~190 110V models 110~180 Short Circuit protection Continuous, Auto-recovery Thermal shutdown On Case 115 ºC Line voltage regulation 24V & 48V models ±0.2 ±0.5 110V models ±0.3 % of Vin Load voltage regulation 0% to 100% Full Load, 24V/48V ±0.5 ±0.75 % 110V ±0.5 Temperature coefficient ±0.03 %/oC Ripple & Noise 20MHz Bandwidth, 24V/48V Vin, 12V/15V Vout 100 200 mV p-p 20MHz Bandwidth, 24V/48V Vin, others 130 250 20MHz Bandwidth, 110V Vin 100 300 Transient Response Deviation 24V/48V models, 5V Vout ±3 ±7.5 % of Max Others ±3 ±5 Transient Recovery 300 500 µsec Voltage adjustment range 24V Vin, 5V/15V Vout models -9/+10 % 24V others ±10 48V/110V models -5/+10 General Specifications Parameters Conditions Typical Maximum Units Switching frequency 24V/48V models, 100% load 250 KHz 110V models, 100% load 220 Operating temperature 24V/48V models with derating -40 to +85 oC 110V models with derating -40 to +100 Storage temperature -55 to +125 oC Maximum case temperature 110 oC Cooling Free Air Convection or Forced Convection 200-1000 LFM airflow Humidity 95 % RH Case material Aluminum alloy or non-conductive Black Plastic (UL94V-0 rated) Weight 24V models 80 g 48V models 70 110V models 46 Weight with optional aluminum case 24V models 100 48V models 90 Weight with Heatsink 24V models 116 110V models 76

www.aimtec.com Tel: +1 514 620 2722 Toll free: + 1 888 9 AIMTEC (924 6832) F 051e R1 3 of 13 North America only General Specifications (Continued) Parameters Conditions Typical Maximum Units MTBF >500,000 hrs (MIL-HDBK-217 F at +25 oC) Maximum soldering temperature 1.5mm from case for 10 sec 260 oC Environment Approval Parameters Conditions Cooling EN60068-2-1, 110V models only Dry heat EN60068-2-2, 110V models only Damp heat EN60068-2-30, 110V models only Shock and Vibrations IEC/EN61373 on all models Safety Specifications Parameters Standards EMI - Conducted and radiated emission 24V CISPR32/EN55032, class A and class B with the recommended EMC circuit Meet EN50121-3-2, CE&RE with the recommended EMC circuit Meet EN55016-2-1 48V CISPR32/EN55032, class A and class B with the recommended EMC circuit Meet EN50121-3-2, CE & RE with the recommended EMC circuit 110V CISPR32/EN55032, Class A, Class B with the recommended EMC circuit Electrostatic Discharge Immunity 24V/48V IEC 61000-4-2, Contact ±6KV Air ±8KV, Criteria B Meet EN50121-3-2, Contact ±6KV Air ±8KV 110V IEC 61000-4-2, Contact ±6KV Air ±8KV, Criteria B RF, Electromagnetic Field Immunity 24V/48V IEC 61000-4-3, 20V/m, Criteria A Meet EN50121-3-2, 20V/m 110V IEC 61000-4-3, 10V/m, Criteria A Electrical Fast Transient/Burst Immunity 24V/48V IEC 61000-4-4, ±2kV with the recommended EMC circuit, Criteria B Meet EN50121-3-2, ±2kV 110V IEC 61000-4-4, ±2kV with the recommended EMC circuit, Criteria B Surge Immunity 24V Meet EN50121-3-2, L to L ±1KV (42Ω 0.5uF) with the recommended EMC circuit 48V Meet EN50121-3-2, L to L ±1KV (42Ω 1.2/50us_ with the recommended EMC circuit 110V IEC 61000-4-5, L to L ±2KV with the recommended EMC circuit, Criteria B Meet EN50155, +/-1.8kV (5/50us) with the recommended EMC circuit Criteria B RF, Conducted Disturbance Immunity 24V/48V IEC 61000-4-6, 10Vrms, Criteria A Meet EN50121-3-2, 10Vrms 110V IEC 61000-4-6, 10Vrms, Criteria A Immunity of Short interruption 110V Meet EN50155, 100%-0%, 10ms, Criteria B Pin Out Specifications Pin Single 1 +V Input

2 On/Off Control

4 Vo -

5 Sense -

6 Trim

7 Sense +

8 Vo +

www.aimtec.com Tel: +1 514 620 2722 Toll free: + 1 888 9 AIMTEC (924 6832) F 051e R1 4 of 13 North America only 24V & 48V Models Dimensions DIV: 2.54 x 2.54 Dimensions: mm (inch) Case Tolerance: ±0.50 (0.02) Pin Tolerance: ± 1.50 (0.06) Pin diameter Tolerance: ±0.10 (0.004) Pin 1, 2, 3, 5, 6 & 7 diameter: 1.00 (0.04) Pin 4 & 8 diameter: 1.50 (0.06) Mounting hole screw torque: max 0.4 N m 40.20 (1.58) 61.80 (2.43) 47.20 (1.86) 26.20 (1.03) BOTTOM VIEW 12.70±1.00 (0.50±0.04) 4.50 (0.18) 50.80 (2.00) 12.48 (0.49) 7.62 (0.30) 2xM3 3.00(0.12) 6XØ1.00 (0.04) Side view 2 x ᴓ 3.50(0.14) 2xᴓ 1.50(0.06) 2 x ᴓ 2.00(0.08) 6 x ᴓ 1.50(0.06) 110V Models Dimensions DIV: 2.54 x 2.54 Dimensions: mm (inch) Case Tolerance: ±0.50 (0.02) Pin Tolerance: ± 1.50 (0.06) Pin diameter Tolerance: ±0.10 (0.004) Pin 1, 2, 3, 5, 6 & 7 diameter: 1.00 (0.04) Pin 4 & 8 diameter: 1.50 (0.06) Mounting hole screw torque: max 0.4 N m 39.20 (1.54) 60.80 (2.39) 47.20 (1.86) 26.20 (1.03) BOTTOM VIEW 12.70±1.00 (0.50±0.04) 4.20 (0.17) 50.80 (2.00) 7.62 (0.30) 2xM3 3.00(0.12) 6XØ1.00 (0.04) Side view Aluminum baseplate 2 x ᴓ 3.50(0.14) 2xᴓ 1.50(0.06) 2 x ᴓ 2.00(0.08) 6 x ᴓ 1.50(0.06) 12.48 (0.49)

www.aimtec.com Tel: +1 514 620 2722 Toll free: + 1 888 9 AIMTEC (924 6832) F 051e R1 5 of 13 North America only 24V Models Dimensions with Optional Heatsink (-K option) DIV: 2.54 x 2.54 Dimensions: mm (inch) Case Tolerance: ±0.50 (0.02) Pin Tolerance: ± 1.50 (0.06) Pin diameter Tolerance: ±0.10 (0.004) Pin 1, 2, 3, 5, 6 & 7 diameter: 1.00 (0.04) Pin 4 & 8 diameter: 1.50 (0.06) Mounting hole screw torque: max 0.4 N m 40.20 (1.58) 61.80 (2.43) 47.20 (1.86) 26.20 (1.03) BOTTOM VIEW 27.70±1.00 (1.09±0.04) 4.50 (0.18) 50.80 (2.00) 7.62 (0.30) 2xM3 3.00(0.12) 6XØ1.00 (0.04) Side view 2xᴓ 1.50(0.06) 2 x ᴓ 3.50(0.14) 2 x ᴓ 2.00(0.08) 6 x ᴓ 1.50(0.06) 12.48 (0.49) 110V Models Dimensions with Optional Heatsink (-K option) Dimensions: mm (inch) Case Tolerance: ±0.50 (0.02) Pin Tolerance: ± 1.50 (0.06) Pin diameter Tolerance: ±0.10 (0.004) Pin 1, 2, 3, 5, 6 & 7 diameter: 1.00 (0.04) Pin 4 & 8 diameter: 1.50 (0.06) Mounting hole screw torque: max 0.4 N m 39.20 (1.54) 62.00 (2.44)47.20 (1.86) 26.20 (1.03) BOTTOM VIEW 30.80±1.00 (1.21±0.04) 4.20 (0.17) 50.80 (2.00) 7.62 (0.30) 2xM3 3.00(0.12) 6XØ1.00 (0.04) Side view 2xᴓ 1.50(0.06) 12.48 (0.49) DIV: 2.54 x 2.54 2 x ᴓ 3.50(0.14) 2 x ᴓ 2.00(0.08) 6 x ᴓ 1.50(0.06)

www.aimtec.com Tel: +1 514 620 2722 Toll free: + 1 888 9 AIMTEC (924 6832) F 051e R1 6 of 13 North America only 24V & 48V Models Dimensions with Optional Aluminum Alloy Case (-M option) DIV: 2.54 x 2.54 Dimensions: mm (inch) Case Tolerance: ±0.50 (0.02) Pin Tolerance: ± 1.50 (0.06) Pin diameter Tolerance: ±0.10 (0.004) Pin 1, 2, 3, 5, 6 & 7 diameter: 1.00 (0.04) Pin 4 & 8 diameter: 1.50 (0.06) Mounting hole screw torque: max 0.4 N m 40.20 (1.58) 61.80 (2.43) 47.20 (1.86) 26.20 (1.03) BOTTOM VIEW 14.60±1.00 (0.58±0.04) 4.50 (0.18) 50.80 (2.00) 7.62 (0.30) 2xM3 3.00(0.12) 6XØ1.00 (0.04) Side view 2xᴓ 1.50(0.06) 12.48 (0.49) 3 2 x ᴓ 3.50(0.14) 2 x ᴓ 2.00(0.08) 6 x ᴓ 1.50(0.06) 50.90 (2.00) 56.00 (2.21) Derating -40 0 40 60 80 100 100 Safe Operating Area Output Power (%) Ambient Temperature º C AM100QB-2405SH22-NZ-K(with Heatsink) Vin=24V -20 -40 0 40 60 80 100 100 Safe Operating Area Output Power (%) Ambient Temperature º C AM100QB-2412SH22-NZ-K(with Heatsink) Vin=24V -20

www.aimtec.com Tel: +1 514 620 2722 Toll free: + 1 888 9 AIMTEC (924 6832) F 051e R1 7 of 13 North America only -40 0 40 60 80 100 100 Safe Operating Area Output Power (%) Ambient Temperature º C AM100QB-2415SH22-NZ-K(with Heatsink) Vin=24V -20 -40 0 40 60 80 100 100 Safe Operating Area Output Power (%) Ambient Temperature º C AM100QB-2424SH22-NZ-K(with Heatsink) Vin=24V -20 -40 0 40 60 80 100 100 Safe Operating Area Output Power (%) Ambient Temperature º C AM100QB-2428SH22-NZ-K(with Heatsink) Vin=24V -20 -40 0 40 60 80 100 100 Safe Operating Area Output Power (%) Ambient Temperature º C AM100QB-2448SH22-NZ-K(with Heatsink) Vin=24V -20 -40 0 40 60 80 100 100 Safe Operating Area Output Power (%) Ambient Temperature º C AM100QB-4805S-NZ -20 Vin = 24V Vin = 48V -40 0 40 60 80 100 100 Safe Operating Area Output Power (%) Ambient Temperature º C AM100QB-4805S-NZ With Optional Aluminum case -20 Vin = 24V Vin = 48V

www.aimtec.com Tel: +1 514 620 2722 Toll free: + 1 888 9 AIMTEC (924 6832) F 051e R1 8 of 13 North America only -40 0 40 60 80 100 100 Safe Operating Area Output Power (%) Ambient Temperature º C AM100QB-4812/15/24/48S-NZ -20 Vin = 24V Vin = 48V -40 0 40 60 80 100 100 Safe Operating Area Output Power (%) Ambient Temperature º C AM100QB-4812/15/24/48S-NZ With Optional Aluminum Case -20 Vin = 24V Vin = 48V AM100QB-11012S-NZ AM100QB-11012S-NZ-K - 40 - 20 0 20 40 60 80 100 100 Output Power (%) Ambient Temperature º C No Heatsink, 1000LFM No Heatsink 400LFM Safe Operating Area No Heatsink 200LFM No Heatsink Natural Convection - 40 - 20 0 20 40 60 80 100 100 Output Power (%) Ambient Temperature º C Heatsink, 1000LFM Heatsink 400LFM Safe Operating Area Heatsink 200LFM Heatsink Natural Convection AM100QB-11015S-NZ AM100QB-11015S-NZ-K - 40 - 20 0 20 40 60 80 100 100 Output Power (%) Ambient Temperature º C No Heatsink, 1000LFM No Heatsink 400LFM Safe Operating Area No Heatsink 200LFM No Heatsink Natural Convection - 40 - 20 0 20 40 60 80 100 100 Output Power (%) Ambient Temperature º C Heatsink, 1000LFM Heatsink 400LFM Safe Operating Area Heatsink 200LFM Heatsink Natural Convection 30 50

www.aimtec.com Tel: +1 514 620 2722 Toll free: + 1 888 9 AIMTEC (924 6832) F 051e R1 9 of 13 North America only AM100QB-11024S-NZ AM100QB-11024S-NZ-K - 40 - 20 0 20 40 60 80 100 100 Output Power (%) Ambient Temperature º C No Heatsink, 1000LFM No Heatsink 400LFM Safe Operating Area No Heatsink 200LFM No Heatsink Natural Convection - 40 - 20 0 20 40 60 80 100 100 Output Power (%) Ambient Temperature º C Heatsink, 1000LFM Heatsink 400LFM Safe Operating Area Heatsink 200LFM Heatsink Natural Convection Typical Application Circuits 24V & 48V Models DC DC + Vin - Vin Cin 220 µF Cout +Vout - Vout Single Output + + FUSE Output 5V 12V/15V 24V 48V Cout 470 µF 220 µF 100 µF 100 µF FUSE 20A for 24V models, 10A for 48V models 110V Models DC DC + Vin - Vin Cin 100 µF Cout 220 µF +Vout - Vout Single Output + +

www.aimtec.com Tel: +1 514 620 2722 Toll free: + 1 888 9 AIMTEC (924 6832) F 051e R1 10 of 13 North America only Recommended EMC Circuits 24V Models DC DC +Vout - Vout CY1 2.2nF/400VAC + Vin - Vin + Vout C11 47µF - Vout CY2 2.2nF/400VAC CY4 1nF/400VAC 10µF + Vin - Vin LCM1 1.6mH 150µF 10µF 10µF 10µF 10µF 10µF C10 10µF CY3 1nF/400VAC LCM1 1.6mH 10µF 10µF 48V Models DC DC +Vout - Vout CY1 1nF/400VAC + Vin - Vin + Vout 47µF - Vout CY2 1nF/400VAC CY4 1nF/400VAC 2.2µF LDM 1.5µH + Vin - Vin LCM1 1mH 150µF 2.2µF 2.2µF 2.2µF 2.2µF 2.2µF 2.2µF CY3 1nF/400VAC 110V Models DC DC +Vout - Vout MOV S20K130 CY1 2.2nF/400VAC + Vin - Vin + Vout - Vout CY2 2.2nF/400VAC CY3 2.2nF/400VAC CY4 2.2nF/400VAC LCM2 C5C4 LCM1 C2C1 C3C7C6 C8 LDM 10µH +++ + Vin - Vin

www.aimtec.com Tel: +1 514 620 2722 Toll free: + 1 888 9 AIMTEC (924 6832) F 051e R1 11 of 13 North America only Trimming Output voltage can be externally trimmed by utilizing the methods as shown below Fixed Resistor Variable Potentiometer Leave open if not used. AM100QB-xx05SH22-NZ, xx can be 24 or 48, 24V model can only be trimmed down to 9%, 48V model can only be trimmed down to 5% Trim down % 1 2 3 4 5 6 7 8 9 Trim up % 1 2 3 4 5 6 7 8 9 10 AM100QB-xx12SH22-NZ, xx can be 24 or 48, 48V model can only be trimmed down to 5% Trim down % 1 2 3 4 5 6 7 8 9 10 Trim up % 1 2 3 4 5 6 7 8 9 10 MOV S20K130 (Varistor) C6, C7, C8, C9 100uF/400V (Electrolytic Capacitor C1, C2, C3, C4, C5 2.2uF/250V LDM 10uH (Shielded Inductor) LCM1 2200uH, 3.0A min. LCM2 4400uH, 3.0A min. D1 SF306 CY1, CY2, CY3, CY4 2.2nF / 400Vac (Y2 Safety Capacitor

www.aimtec.com Tel: +1 514 620 2722 Toll free: + 1 888 9 AIMTEC (924 6832) F 051e R1 12 of 13 North America only AM100QB-xx15SH22-NZ, xx can be 24 or 48, 24V model can only be trimmed down to 9%, 48V model can only be trimmed down to 5% Trim down % 1 2 3 4 5 6 7 8 9 Trim up % 1 2 3 4 5 6 7 8 9 10 AM100QB-xx24SH22-NZ, xx can be 24 or 48, 48V model can only be trimmed down to 5% Trim down % 1 2 3 4 5 6 7 8 9 10 Trim up % 1 2 3 4 5 6 7 8 9 10 AM100QB-2428SH22-NZ Trim down % 1 2 3 4 5 6 7 8 9 10 Trim up % 1 2 3 4 5 6 7 8 9 10 AM100QB-2448SH22-NZ Trim down % 1 2 3 4 5 6 7 8 9 10 Trim up % 1 2 3 4 5 6 7 8 9 10 AM100QB-4848SH22-NZ, can only be trimmed down to 5% Trim down % 1 2 3 4 5 Trim up % 1 2 3 4 5 6 7 8 9 10

www.aimtec.com Tel: +1 514 620 2722 Toll free: + 1 888 9 AIMTEC (924 6832) F 051e R1 13 of 13 North America only AM100QB-11012S-NZ Trim down % 1 2 3 4 5 6 7 8 9 10 Trim up % 1 2 3 4 5 6 7 8 9 10 AM100QB-11015S-NZ Trim down % 1 2 3 4 5 6 7 8 9 10 Trim up % 1 2 3 4 5 6 7 8 9 10 AM100QB-11024S-NZ Trim down % 1 2 3 4 5 6 7 8 9 10 Trim up % 1 2 3 4 5 6 7 8 9 10 NOTE: 1. Datasheets are updated as needed and as such, specifications are subject to change without notice. Once printed or downloaded, datasheets are no longer controlled by Aimtec; refer to www.aimtec.com for the most current product specifications. 2. Product labels shown, including safety agency certifications on labels, may vary based on the date manufactured. 3. Mechanical drawings and specifications are for reference only. 4. All specifications are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at rated output load unless otherwise specified. 5. Aimtec may not have conducted destructive testing or chemical analysis on all internal components and chemicals at the time of publishing this document. CAS numbers and other limi ted information are considered proprietary and may not be available for release. 6. This product is not designed for use in critical life support systems, equipment used in hazardous environments, nuclear control s ystems or other such applications which necessitate