Features
What is the trouble with multi-output power supply? vRequires trial sample in a short period after the specification is fixed. vHave to pay the cost of developing power supply and its initial-cost. vHave trouble on the spending cost and the time for applying the safety standards. vHave problem of CE marking for exporting to EU. vHave to spend time more for designing one's own products or system without power supply. vThe standardization of power supply. Considering OEM Outputs: up to 6CH Total wattage: 250W Outputs: up to 7CH Total wattage: 400W/600W Outputs: up to 14CH Total wattage: 800W (Max. 1000W peak) Single Output Output wattage: 1250W Modular Watt Box Multi-Output Power Supplies 250W/400W/600W/800W/1250W 1 sample delivering 2weeks 3 to 4 months 2 initial cost Design cost no need Application for safety standardno need Tools and dais no need 3 safety standard application approved by UL/C-UL/SEMKO, need compliance with CE-Marking 4 harmonics restrain installed PFHC EN61000-3-2 need to design the circuit 5 size already known before starting the designunknown until design finish 6 min. order qty. from 1 unit has to consider the ordering qty., delivery term, stock Alpha series OEM power supply
Example of the conformation [Alpha 250S] 1) input voltage range universal input range from 85V to 265VAC world wide commercial input 2) Harmonics Current Control Alpha has unique active filter for compliance with IEC1000-3-2/EN61000-3-2 harmonicslimitation. 3) Adapted the international safety standards Listed UL1950, CSA950(C-UL), EN60950 (SEMCO), 4) Conformed with CE marking Alpha is conformed with 'Low-Voltage Directive' of the CE-Marking and indicated. 5) EMI (Conducted EMI / Radiated RFI) Alpha is met the EMI Standard EN55022 class A/VCCI Class A (CISPR pub.22). Alpha will be met EN55022 class B and VCCI class B using Densei-Lambda Noise Filters. 6) EMS (immunity) Adapted EN61000-4 series (IEC61000-4series) EN61000-4-2 Level 4 : Electro-Static Discharge EN61000-4-3 Level 3 : Radiated Electromagnetic Radio Frequency EN61000-4-4 Level 4 : First Transient Barest EN61000-4-5 Level 3 : Input surge Voltage 7) Alpha 400/600/800: 3 years warranty, Alpha 250S: 2 years warranty 1)Alpha 250S available for 4 slots for the output modules can be conformed the outputs. Slot1&Slot2 use for main board only. 2)The total outputs wattage of the Alpha 250S is maximum 250W. 3)Each specified output wattage of the output module derating is depend on arrangement of position in the slots, output voltage setting and ambient temperature. 4)Internal input fuses Alpha 250S: 250V8A 5) Harmonics Current Correction Circuit Switching Frequency Alpha 250S :100kHz (fixed : typ.) 6)Converter Switching Frequency Alpha 250S :200kHz (fixed : typ.)
[Alpha 400/600] 1)Alpha 400/600 available for 5 slots for the output modules can be conformed the outputs. 2)The total outputs wattage of the Alpha 400 is maximum 400W. 3)The total outputs wattage of the Alpha 600 is maximum 600W. 4)Each specified output wattage of the output module derating is depend on arrangement of position in the slots, output voltage setting and ambient temperature. 5)Internal input fuses Alpha 400: 250V10A Alpha 600: 250V15A 6) Harmonics Current Correction Circuit Switching Frequency Alpha 400 :100kHz (fixed : typ.) Alpha 600 :200kHz (fixed : typ.) 7)Converter Switching Frequency Alpha 400 :200kHz (fixed : typ.) Alpha 600 :200kHz (fixed : typ.) 1)Alpha 800 available for 7 slots for the output modules can be conformed the outputs. 2)The total outputs wattage of the Alpha 800 is maximum 800W. 3)Each specified output wattage of the output module derating is depend on arrangement of position in the slots, output voltage setting and ambient temperature. 4)Internal input fuses Alpha 800: 250V20A 5) Harmonics Current Correction Circuit Switching Frequency Alpha 800 :100kHz (fixed : typ.) 6)Converter Switching Frequency Alpha 800 :200kHz (fixed : typ.) [Alpha 800]
2.RATED OUTPUT VOLTAGE V 3.3 5 5 3.3 5 12 24 3.3 5 12 24 3.MAXIMUM OUTPUT CURRENT A 35 16 35 16 35 8 10 10 10 8 4 5.MAXIMUM OUTPUT RIPPLE mV 100 100 100 100 100 240 480 100 100 240 480AND NOISE VOLTAGE (*1) 6.MAXIMUM LINE REGULATION ( * 2 ) m V 2 52 52 52 52 56 07 22 52 56 07 2 7.MAXIMUM LOAD REGULATION (*3) mV 100 100 100 100 100 240 480 100 100 240 480 10.OPERATING AMBIENT TEMPERATURE 0~+60°C ( 0~+50°C : 100%, +60°C : 75% ) 11.REMOTE SENSING Available (Main bord output, L module, A module only) 12.REMOTE ON/OFF CONTROL Available 13.SERIES OPERATION Available (can be operated in series between each output of Output Module and dual Outputs Module) 14.PARALLEL OPERATION Available (Please contact to Densei-Lambda before use in parallel operation of the Modules) 15.INPUT VOLTAGE DETECTOR SIGNAL Optionfor M J Module: detecting the output of the active filter (TTL open collector) mAlpha 250S Common specification mAlpha 250S Specification for Output Modules For Slot 1&2 For Slot 3 or Slot 4 OUTPUT MODULE - - - - L A B C D E F G H J M 1. NUMBER of SLOTS 2 2 2 2 1 1 1 1 1 1 1 1 1 1 1 MAIN BOARD Specifications(please read the instruction manual before design) Alpha250S 1 NUMBER of SLOTS 4 Slots (6 channels max.)
2 INPUT VOLTAGE RANGE 85-265VAC(47-63Hz) 85-90VAC (required the output derating)
MAXIMUM TOTAL OUTPUT WATTAGE 250W 4 INPUT CURRENT typ. 4A: 100VAC/2A: 200VAC at full load 5 INRUSH CURRENT 40A max. HARMONICS CURRENT CONTROL meet EN61000-3-2 (Harmonics current correction range: 85-255VAC) 8 EFFICIENCY (typ.) 75%: input 100/200VAC nominal outputs voltage at maximum total output power MISSING CYCLE HOLD UP TIME (typ.) minimum 16mS: input 100/200VAC nominal outputs voltage at maximum total output power 10 LEAKAGE CURRENT maximum 0.95mA at full load OPERATING AMBIENT TEMPERATURE 0~+60°C (0-50°C : 100%, +60°C : 75%)
12 OPERATING AMBIENT HUMIDITY 30~90%RH (no condensation)
STORAGE AMBIENT TEMPERATURE -30~+85˚C
14 STORAGE AMBIENT HUMIDITY 10~95%RH (no condensation)
15 COOLING Forced air cooling with internal fan
16 WITHSTAND VOLTAGE input - FG 1.5kVAC for one minute (20mA): input - output 3kVAC for one minute (20mA) 17 INSULATION RESISTOR minimum 100M ohm (output - FG 500VDC. 25˚C. 70%RH)
18 VIBRATION
Vibration cycles at 10-55Hz, sweep time for one minute, 19.6m/s2 constant, X,Y,Z axis on each side for one hour with no input. 19 MECHANICAL SHOCK maximum 196.1 m/s2 20 SAFETY STANDARDS Approved by UL1950, CSA950 (C-UL), EN60950(SEMKO), meet DENTORI (nominal input voltage 100VAC) 21 CONDUCTED E.M.I. meets EN55022-class A, meet VCCI-class A, CISPR Pub.22 22 RADIATED R.F.I. meets EN55022-class A, VCCI-class A, CISPR Pub.22 23 NOISE IMMUNITY meets EN61000-4-2 Level 4, EN61000-4-3 Level 3, EN61000-4-4 Level4 and EN61000-4-5 Level 3 24 WEIGHT (typ.) 1270g 25 SIZE (W x H x D) 126.5 x 49.5 x 259.5mm 5 3.3 5 12 5 24 12 12 12 24 24 24 5 5 555 452444222 55 100 100 100 240 100 480 240 240 240 480 480 480 100 100 25 25 25 60 25 72 60 60 60 72 72 72 25 25 100 100 100 240 100 480 240 240 240 480 480 480 100 100 (*1) 100MHz (measured by the Japanese Standard EIAJ RC-9131) (*2) Input Voltage 85 - 265VAC at constant load (*3) no-load to full-load, at constant input voltage (when use the remote sensing, the level will be the same as the line regulation.) (*4) Constant Current Auto-Reset (pre-set before shipment: fixed the limitation) (*5) Shut Down method with Manual Reset (restart the input to be reset)
Alpha400 Alpha600 Alpha800 185 System Power Supply mAlpha 400/600/800 Common specification 1 NUMBER of SLOTS 5 Slots (7 channels max.) 5 Slots (7 channels max.) 7 Slots (14 channels max.) MAXIMUM TOTAL OUTPUT WATTAGE 400W 600W 800W(1000W peak) 4 INPUT CURRENT typ. 7A: 100VAC/3.5A: 200VAC at full load 10A: 100VAC/ 5A: 200VAC at full load 13A: 100VAC/ 6.5A: 200VAC at full load 5 INRUSH CURRENT 20A max. 30A max. 40A max. HARMONICS CURRENT CONTROL meet EN61000-3-2 (Harmonics current correction range: 85-255VAC) 8 EFFICIENCY (typ.) 75%: input 100/200VAC nominal outputs voltage at maximum total output power MISSING CYCLE HOLD UP TIME (typ.) minimum 16mS: input 100/200VAC nominal outputs voltage at maximum total output power 10 LEAKAGE CURRENT maximum 0.95mA at full load OPERATING AMBIENT TEMPERATURE 0~+60°C (0-50°C : 100%, +60°C : 75%) STORAGE AMBIENT TEMPERATURE -30~+85˚C 16 WITHSTAND VOLTAGE input - FG 1.5kVAC for one minute (20mA): input - output 3kVAC for one minute (20mA) 17 INSULATION RESISTOR minimum 100M ohm (output - FG 500VDC. 25˚C. 70%RH) Vibration cycles at 10-55Hz, sweep time for one minute, 19.6m/s2 constant, X,Y,Z axis on each side for one hour with no input. 19 MECHANICAL SHOCK maximum 196.1 m/s2
20 SAFETY STANDARDS Approved by UL1950, CSA950 (C-UL), EN60950(SEMKO), EN60601-1, UL2601-1, meet DENTORI
21 CONDUCTED E.M.I. meets EN55022-class A, meet VCCI-class A 22 RADIATED R.F.I. meets EN55022-class A, VCCI-classA 23 NOISE IMMUNITY meets EN61000-4-2 Level 4, EN61000-4-3 Level 3, EN61000-4-4 Level4 and EN61000-4-5 Level 3 24 WEIGHT (typ.) 2100g 2500g 3400g Specifications(please read the instruction manual before design) mAlpha 400/600/800 Specification for Output Modules Output Module name A B C D E F G H M N P Q R T (*1) 100MHz (measured by the Japanese Standard EIAJ RC-9131) (*2) Input Voltage 85 - 265VAC at constant load (*3) no-load to full-load, at constant input voltage (when use the remote sensing, the level will be the same as the line regulation.) (*4) Constant Current Auto-Reset (pre-set before shipment: fixed the limitation) (*5) Shut Down method with Manual Reset (restart the input to be reset) 1. NUMBER of SLOTS 2111 1 22 1 11 1 122 2. RATED OUTPUT VOLTAGE V 5 5 12 24 12 12 12 24 24 24 12 24 24 12 3.3 3.3 2 MAXIMUM OUTPUT CURRENT A 6 0 2 5 1 6 888 3 3 2 5 558558 2 5 6 0 6 0 5. MAXIMUM OUTPUT RIPPLE mV 100 100 240 480 240 240 240 480 480 480 240 480 480 240 100 100 100 AND NOISE VOLTAGE (*1) P-P 6. MAXIMUM LINE REGULATION (*2) mV 25 25 60 72 60 60 60 72 72 72 60 72 72 60 25 25 25 7. MAXIMUM LOAD REGULATION (*3) mV 100 100 240 480 240 240 240 480 480 480 240 480 480 240 100 100 100 10. OPERATING AMBIENT TEMPERATURE 0~+60°C ( 0~+50°C : 100%, +60°C : 75% ) 11. REMOTE SENSING Available (without dual outputs module: E, H, P Module) 12. REMOTE ON/OFF CONTROL Option I J: output inhibits on each output (TTL level) OUTPUT INHIBIT CONTROL MJ: output inhibits on all the outputs (TTL level) 13. SERIES OPERATION Available (can be operated in series between each output of Output Module and dual Outputs Module) 14. PARALLEL OPERATION Available (Please contact to Densei-Lambda before use in parallel operation of the Modules) 15. OUTPUT VOLTAGE MONITOR SIGNAL Option for I J Module: monitoring the output voltage up or down (TTL open collector) 16. INPUT VOLTAGE DETECTOR SIGNAL Option for M J Module: detecting the output of the active filter (TTL open collector)
Note 1. Name Plate (product name: indicate the specification of input/output) Note 2. Please keep the space more than 50 mm for airflow. Note 3. Please refer to the size of the Output Module. Note 4. The tapped holes for fixing 9-M4 (the fixing screw thread length should not be exceeded 4.5mm.) (Unit in mm) [Alpha 250S] Note 1. Name Plate (product name: indication of the specification of input/output) Note 2. Please keep the space more than 50 mm for airflow. Note 3. Please refer to the next chapter of input output terminal. Note 4. The tapped holes for fixing 8-M4 (the fixing screw thread length should not be exceeded 4.5mm.) (Unit in mm) [Alpha 400] FAN AIR FLOW SEE NOTE 4 (2)274.551 6351 SLOT OUTPUT MODULE (SEE NOTE 3) 23150.5 24950.5 9.5 22.5 9.5 3350.5 126.551 15 23 80.550.5 65.75 (SEE NOTE 2) SEE NOTE 4 SEE NOTE 1 INPUT
Note 1. Name Plate (product name: indication of the specification of input/output) Note 2. Please keep the space more than 50 mm for airflow. Note 3. Please refer to the next chapter of input output terminal. Note 4. The tapped holes for fixing 8-M4 (the fixing screw thread length should not be exceeded 4.5mm.) (Unit in mm) [Alpha 600] Note 1. Name Plate (product name: indication of the specification of input/output) Note 2. Please keep the space more than 50 mm for airflow. Note 3. Please refer to the next chapter of input output terminal. Note 4. The tapped holes for fixing 8-M4 (the fixing screw thread length should not be exceeded 4.5mm.) Note 5. The tapped holes for supporting 2-M4 on vertical mounting. (the fixing screw thread length should not be exceeded 4.5mm) (Unit in mm) [Alpha 800] FAN 318.551 (2) SEE NOTE 4 SEE NOTE 4 INPUT 9.5 22.5 9.5 AIR FLOW (SEE NOTE 2) 26750.5 26750.5 6351 OUTPUT MODULE (SEE NOTE 3) 126.551 8050.5 66.75 3350.5 2315 SEE NOTE 1
mAlpha 1250 Common specification
1 Nominal Output Voltage
2 Maximum Output Current
3 Maximum Output Power
4 Efficiency (typ) (*1)
5 Input Voltage Range (*2)
6 Input Current (typ)
7 Output Voltage Accuracy
8 Output Voltage Range (*3)
9 Maximum Ripple & Noise (*4)
10 Maximum Line Regulation
11 Maximum Load Regulation (*5)
12 Over Current Protection (*6)
13 Over Voltage Protection (*7)
14 Remote Sensing
15 Remote On/Off
16 Series / parallel operation
17 Inrush Current (*8)
18 PFHC
19 Power Factor
20 Over Output Power Protection
21 Hold-up time (typ) (*1)
22 Leakage Current (*1)
23 Operating Temperature
24 Operating Humidity
25 Storage Temperature
26 Storage Humidity
27 Cooling
28 Withstand Voltage
29 Isolation Resistance
30 Vibration
31 Shock
32 Safety Standard
33 Conducted Emission
34 Radiated Emission
35 Immunity
36 Weight
37 Size (W x H x D)
Specifications(please read the instruction manual before design) 12V 24V 104A 52A 1248W 1248W 80% 200 ~ 265VAC(47 ~ 63Hz) 7.0A: 230VAC AT 1248W 11.88 ~ 12.12V 23.76 ~ 24.24V Fixed 240mV 480mV 60mV 72mV 240mV 480mV 105 ~ 112A 53 ~ 58A 16.2 ~ 18.6V 32.4 ~ 37.2V Possible(Max 1V for total drop) Available Not available 40A max. (Ta=25˚C Cold start) Built to meet EN61000-3-2 (PFHC Range : 200 ~ 255VAC) 230VAC: 0.95 at 1248W more than 1260W 10ms Less than 0.95mA 0 ~ +50˚C 30 ~ 90%Rh (No Dewdrop) -30 ~ +85˚C 10 ~ 95%Rh (No Dewdrop) Forced Air by Blower Fan Input - FG: 1.5kVAC (20mA) for 1min. Input - Output: 3kVAC (20mA) for 1min. More than 100MΩ Output - FG: 500VDC at 25˚C, 70%Rh At no operating, 10 ~ 55Hz (Sweep for 1min) 19.6m/s2 Constant, X, Y, Z, 1hour each Less than 196.1m/s2 Built to meet UL60950, CSA60950-00(C-UL), EN60950(SEMKO) Built to meet EN55022-A, VCCI-A Built to meet EN55022-A, VCCI-A Built to meet EN61000-4-2 Level 4, EN61000-4-3 Level 3, EN61000-4-4 Level 4, EN61000-4-5 Level 3 3400g 175.5mm x 63mm x 279mm (Refer to Outline Drawing) *Read instruction manual carefully, before using the power supply unit. =NOTES= (*1) At 230VAC Nominal output voltage and maximum output current. Total output power 1248W (Ta=25˚C) (*2) For cases where conformance to various safety specs are required, input voltage range will be 200 ~ 240VAC (50/60Hz). (*3) Factory Programmed (Available for 5 10% setting Range) (*4) 100MHz B. W JEITA RC-9131 Method (*5) When remote sense connected. (*6) Constant Current Limit Auto recovery. (*7) Output Shut Down Method Manual reset (Line recycle). (*8) When resuming operation in less than 10 sec. after power failure at no load, soft start circuit will not limit the inrush current at turn - on. Not applicable for the inrush current to Noise Filter less than 0.2 ms.