AF09-22-00-11 ABB | Alldatasheet
Document overview
- Manufacturer or author: Provided By alldatasheet.com(free datasheet download site)
- PDF pages: 3
Technical content
Extended Product Type: Product ID: EAN: Catalog Description: Long Description: Minimum Order Quantity: Customs Tariff Number: EAN: Product Net Depth: Product Net Height: Product Net Weight: Product Net Width: Package Level 1 Width: Package Level 1 Length: Package Level 1 Height: Package Level 1 Gross Weight: Package Level 1 EAN: Package Level 2 Units: Package Level 2 Width: Package Level 2 Length: Package Level 2 Height: Package Level 3 Units: Package Level 1 Units: Number of Main Contacts NC: Number of Auxiliary Contacts NO: Number of Auxiliary Contacts NC: Standards: Rated Operational Voltage: Rated Frequency (f): Conventional Free-air Thermal Current (I th Rated Operational Current AC-1 (I e Rated Operational Current AC-3 (I e General Information AF09-22-00-11 1SBL137501R1100 3471523116214 AF09-22-00-11 24-60V50/60HZ 20-60VDC Contactor AF09 4-pole contactors are used for controlling power circuits up to 690 V AC and 440 V DC. They are mainly used for controlling non-inductive or slightly inductive loads (i.e. coil can be used for different control voltages used worldwide without any coil change. AF contactors have built-in surge protection and do not require additional surge suppressors. The AF... series 4-pole contactors are of the block type design. - Main poles and auxiliary contact blocks: 2 N.O. + 2 N.C. main poles, front and side-mounted add-on auxiliary contact blocks (mechanically-linked auxiliary contacts compliant with Annex L of IEC 60947-5-1. N.C. mirror contacts compliant with Annex F of IEC 60947-4-1) - Control circuit: AC or DC please consult your ABB representative. Categories Products Low Voltage Products and Systems Control Products Contactors Block Contactors Ordering 1 piece 85369085 3471523116214 Dimensions 77 mm 86 mm 0.270 kg 45 mm Container Information 87 mm 79 mm 47 mm 0.27 kg 3471523116214 54 piece 250 mm 300 mm 315 mm 1296 piece 1 piece Technical IEC 60947-1 / 60947-4-1 and EN 60947-1 / 60947-4-1, UL 508, CSA C22.2 N°14 Main Circuit 690 V Main Circuit 50 / 60 Hz acc. to IEC 60947-4-1, Open Contactors q = 40 °C 35 A (690 V) 40 °C 25 A (690 V) 60 °C 25 A (690 V) 70 °C 22 A (220 / 230 / 240 V) 60 °C 9 A (380 / 400 V) 60 °C 9 A (415 V) 60 °C 9 A (440 V) 60 °C 9 A (500 V) 60 °C 9.5 A (690 V) 60 °C 7 A AF09-22-00-11
Rated Operational Power AC-3 (P e Rated Short-time Withstand Current cw Maximum Breaking Capacity: Maximum Electrical Switching Frequency: Rated Insulation Voltage (U i Rated Impulse Withstand Voltage imp Maximum Mechanical Switching Frequency: Rated Control Circuit Voltage (U c Operate Time: Connecting Capacity Main Circuit: Connecting Capacity Control Circuit: Wire Stripping Length: Degree of Protection: Terminal Type: Number of Main Contacts NO: Climatic Withstand: Maximum Operating Altitude Permissible: Resistance to Vibrations acc. to IEC 60068-2-6: Resistance to Shock acc. to IEC 60068-2-27: RoHS Status: Ambient Air Temperature: General Use Rating UL/CSA: Tightening Torque UL/CSA: Instructions and Manuals: ABS Certificate: CB Certificate: CCC Certificate: Data Sheet, Technical Information: Declaration of Conformity - CE: (220 / 230 / 240 V) 2.2 kW (380 / 400 V) 4 kW (400 V) 4 kW (415 V) 4 kW (440 V) 4 kW (500 V) 5.5 kW (690 V) 5.5 kW at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 150 A at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 35 A at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 60 A at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 300 A at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 80 A cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 250 A cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 106 A AC-1 600 cycles per hour acc. to UL/CSA 600 V acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 690 V 6 kV 3600 cycles per hour 50 Hz 24 ... 60 V 60 Hz 24 ... 60 V DC Operation 20 ... 60 V Between Coil De-energization and NC Contact Closing 13...98 ms Between Coil De-energization and NO Contact Opening 11...95 ms Between Coil Energization and NC Contact Opening 38...90 ms Between Coil Energization and NO Contact Closing 40...95 ms Flexible with Insulated Ferrule 1x 0.75...4 mm² Flexible with Ferrule 1/2x 0.75...6 mm² Rigid 1/2x 1...6 mm² Rigid 1/2x 1 ... 2.5 mm² Control Circuit 10 mm Main Circuit 10 mm acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20 acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP20 Screw Terminals Environmental Category B according to IEC 60947-1 Annex Q 3000 m 5 ... 300 Hz 4 g closed position / 2 g open position Closed, Shock Direction: B1 25 g Open, Shock Direction: B1 5 g Shock Direction: A 30 g Shock Direction: B2 15 g Shock Direction: C1 25 g Shock Direction: C2 25 g Planned to follow EU Directive 2002/95/EC August 18, 2005 and amendment after 2008 Q1 Close to Contactor for Storage -60...+80 °C Near Contactor for Operation in Free Air -40 ... +70 °C Technical UL/CSA (600 V AC) 25 A Control Circuit 11 in·lb Main Circuit 13 in·lb Certificates and Declarations (Document Number) 1SBC101027M6801 ABS_15-GE1349500-PDA_90682247 CB_SE_70857M1 CCC_2010010304445624 1SBC101421D0201 1SBD250001U1000
DNV Certificate: EAC Certificate: GL Certificate: GOST Certificate: LR Certificate: RINA Certificate: RMRS Certificate: RoHS Information: UL Certificate: E-nummer: ETIM 4: ETIM 5: ETIM 6: Object Classification Code: DNV-GL_E13871 EAC_RU C-FR ME77 B01010 DNV-GL_E13871 GOST_POCCFR.ME77.B07175.pdf LRS_1300087E1 RINA_ELE084013XG RMRS_1400682124 1SBD251011E1000 UL_20100802-E319322-3-1 Classifications 3211407 EC000066 - Magnet contactor, AC-switching EC000066 - Magnet contactor, AC-switching EC000066 - Power contactor, AC switching Q