Panasonic Corporation Automation Controls Business Unit industrial.panasonic.com/ac/e/ EP (AEP) ASCTB3E 201211-T

ORDERING INFORMATION

200A type has been added. High Capacity of Max. 1,000 V DC Cut-off Possible EP RELAYS (AEP) (10A, 20A and 80A types) 10A PC board type 10A TM type 20A TM type 80A type 300A type 200A type New RoHS compliant

FEATURES

  1. High-voltage, high-current control capable 400V DC high-voltage switching and 1,000V DC cut-off has been achieved thanks to a sealed construction with mixed hydrogen gas and the magnetic arc motion through use of a permanent magnet. 2. Compact & Low Operating Sound By using a capsule contact mechanism that is enclosed with hydrogen gas, high- capacity cutoff is possible even with a tiny contact gap. There is little operating sound, which does not change even when large currents are cut off. 3. Arc space unnecessary The enclosure box can be made smaller thanks to an arc-space-free construction from which the arc will not get out. 4. Safety Since the contacts are enclosed in a sealed capsule structure, the arc will not get out, which ensures safety. 5. High contact reliability The contact part is hermetically sealed with H 2 mixed gas, hence the contact resistance remains stable regardless of the ambient conditions. 6. Mounting direction is not specified The weight of the movable parts is light, and also the restoring force is large, hence the relay is relatively unaffected by gravity. 7. Wide selection of models available. Types include PC board type (10A), TM type (10A and 20A), Lead wire type (200A) and Connector type (80A and 300A). 8. Standard compliance The 10A, 20A, 80A type is UL/C-UL standard certified. TYPICAL APPLICATIONS 1. Photovoltaic power generation systems 2. Cogeneration systems 3. Construction machinery 4. Welding equipment 5. Battery charge and discharge control 6. AGV (Automatic guided vehicle) (Unmanned transport carts) 7. Inverter control 8. Elevator, etc. EP Relay Contact arrangement 1: 1 Form A 3: 1 Form A PC board type* 5: 1 Form A TM type*2 AEP 0 Contact rating 1: 10A 2: 20A 7: 200A 8: 80A 9: 300A Coil voltage 12: 24: 48: X0: 12V DC 24V DC 48V DC* 100V DC*1 Notes: *1. 10A type only *2. 10A and 20A types only 10A, 20A and 80A types are UL/C-UL certified.

Panasonic Corporation Automation Controls Business Unit industrial.panasonic.com/ac/e/ EP (AEP) ASCTB3E 201211-T TYPES Standard packing: 10A: Carton: 25 pcs.; Case: 100 pcs. 20A: Carton: 25 pcs.; Case: 50 pcs. 80A: Carton: 1 pc.; Case: 20 pcs. 200A: Carton: 1 pc.; Case: 10 pcs. 300A: Carton: 1 pc.; Case: 5 pcs. Notes: *1. One female connector lead wire for connecting is packaged with the 80A and 300A connector types. -Specifications: Housing: Y azaki 7283-1020 (light gray); Lead wire: 0.5 mm 2 dia. and 300±10 mm 11.811±.394 inch length Lead wire coating color: Pin No. 1: white; Pin No. 2: green *2. Two dedicated M6 bolts is packaged with the 200A type. RATING 1. Coil data Notes: 1. When using a DC power supply, use one that provides a current capacity leeway of at least 150% of the nominal coil current. 2. The 300A type has a built-in coil current switching circuit. After the nominal coil voltage is applied, it automatically switches in approximately 0.1 seconds. Type Nominal coil voltage Contact arrangement Part No. 10A PC board type 12V DC

1 Form A

80A Connector type*1 AEP18012 200A Lead wire type*2 AEP17012 300A Connector type*1 AEP19012 10A PC board type 24V DC AEP31024 10A TM type AEP51024 20A TM type AEP52024 80A Connector type*1 AEP18024 200A Lead wire type*2 AEP17024 300A Connector type*1 AEP19024 10A PC board type 48V DC AEP31048 10A TM type AEP51048 10A PC board type 100V DC AEP310X0 10A TM type AEP510X0 Type Nominal coil voltage Pick-up voltage (at 20°C 68°F) Drop-out voltage (at 20°C 68°F) Nominal coil current Nominal operating power (Nominal voltage applied to the coil, at 20°C 68°F) Max. applied voltage 10A 12V DC 75%V or less of nominal voltage (Initial) 8.3%V or more of nominal voltage (Initial) 0.103A 1.24W 133%V of nominal voltage 20A 4.17%V or more of nominal voltage (Initial) 0.327A 3.9W 80A 8.3%V or more of nominal voltage (Initial) 0.353A 4.2W 200A 8.3%V or more of nominal voltage (Initial) 0.5A 6W 300A 16.7%V or more of nominal voltage (Initial) 3.3A When input: 40 W max. (0.1 sec. from time of input) When retained: 4 W max. 10A 24V DC 8.3%V or more of nominal voltage (Initial) 0.052A 1.24W 20A 4.17%V or more of nominal voltage (Initial) 0.163A 3.9W 80A 8.3%V or more of nominal voltage (Initial) 0.176A 4.2W 200A 8.3%V or more of nominal voltage (Initial) 0.25A 6W 300A 16.7%V or more of nominal voltage (Initial) 1.85A When input: 45 W max. (0.1 sec. from time of input) When retained: 4 W max. 10A 48V DC 8.3%V or more of nominal voltage (Initial) 0.026A 1.24W 10A 100V DC 0.012A

Panasonic Corporation Automation Controls Business Unit industrial.panasonic.com/ac/e/ EP (AEP) ASCTB3E 201211-T 2. Specifications Notes: *1. The upper limit of the ambient temperature is the maximum temperature that can satisfy the coil temperature rise value . Refer to Usage, transport and storage conditions in NOTES. *2. Conditions: Varistor used for coil surge absorption. Note: if a diode is used the life will be lower. *3. Condition: Switches rated number of 10 cycles each time there is a 2,500A cut-off. *4. Please refer to the reference data on the following page for switching and cut-off at 400 V DC and higher. Characteristics Item Specifications 10A type 20A type 80A type 200A type 300A type Rating Contact arrangement 1 Form A Nominal switching capacity (Resistive load) 10A 400V DC 20A 400V DC 80A 400V DC 200A 400V DC 300A 400V DC Max. contact allowance voltage 1,000V DC Short term current 15A (3min) (harness wire: 2mm 30A (30s) (harness wire: 2mm2) 40A (10min) (harness wire: 3mm2) 60A (1min) (harness wire: 3mm2) 120A (15min) (harness wire: 15mm2) 300A (15min) (harness wire: 60mm2) 400A (10min) (harness wire: 100mm2) Max. cut-off current — — 800A 300V DC (1 cycle)*2 2,000A 350V DC (1 cycle)*2 2,500A 300V DC (3 cycles)*3 Overload cut-off rating 30A 400V DC (Min. 50 cycles)*2 60A 400V DC (Min. 50 cycles)*2 120A 400V DC (Min. 50 cycles)*2 — 600A 400V DC (Min. 300 cycles) Reverse cut-off rating –20A 200V DC (Min. 10 cycles)*2 –20A 200V DC (Min. 100 cycles)*2 –80A 200V DC (Min. 1,000 cycles)*2 –200A 200V DC (Min. 1,000 cycles)*2 –300A 200V DC (Min. 100 cycles) Min. switching capacity 1A 6V DC 1A 12V DC — 1A 12V DC 1A 24V DC Contact voltage drop (Initial) Max. 0.5V (When carrying current is 10A) Max. 0.2V (By voltage drop 6V DC 20A) Max. 0.067V (By voltage drop 6V DC 20A) Max. 0.1V (When carrying current is 200A) Max. 0.06V (When carrying current is 300A) Electrical characteristics Insulation resistance (Initial) Min. 100M Ω (at 1,000V DC) Measurement at same location as “Breakdown voltage” section. Breakdown voltage (Initial) Between open contacts 2,500 Vrms for 1min. (Detection current: 10mA) Between contact and coil 2,500 Vrms for 1min. (Detection current: 10mA) Operate time (at 20°C 68°F) Max. 50ms (Nominal voltage applied to the coil, excluding contact bounce time) Max. 30ms (Nominal voltage applied to the coil, excluding contact bounce time) Release time (at 20°C 68°F) Max. 30ms (After the nominal operation voltage stops, without diode) Max. 10ms (After the nominal operation voltage stops) Mechanical characteristics Shock resistance Functional 10A, 20A (ON), 80A (ON), 200A (ON) and 300A (ON) types: Min. 196 m/s 2 (Half-wave pulse of sine wave: 11 ms; detection time: 10µs) 20A (OFF), 80A (OFF), 200A (OFF) and 300A (OFF) types: Min. 98 m/s2 (Half-wave pulse of sine wave: 11 ms; detection time: 10µs) Destructive Min. 490 m/s 2 (Half-wave pulse of sine wave: 6 ms) Vibration resistance Functional 10 to 200Hz, acceleration 43m/s 2 constant (Detection time: 10µs) Destructive 10 to 200Hz, acceleration 43m/s 2 constant (3 directions, each 4 hours) Expected life Mechanical Min. 10 5 Min. 2×105 Electrical*4 (Resistive load) 10A 400V DC Min. 7.5×104 *2 (Switching frequency: 20 times/min) 20A 400V DC Min. 3×103 *2 10A 1,000V DC Min. 103 *2 (Switching frequency: 6 times/min) 80A 400V DC Min. 103 *2 (Switching frequency: 20 times/min) 200A 400V DC Min. 3×103 *2 (Switching frequency: 20 times/min) 60A 1,000V DC Min. 103 *2 (Switching frequency: 6 times/min) 300A 400V DC Min. 103 (Switching frequency: 6 times/min) Conditions Conditions for operation, transport and storage* Ambient temperature: –40°C to +80°C –40°F to +176°F (Storage: Max. +85°C +185°F), Humidity: 5 to 85% R.H. (Not freezing and condensing at low temperature) Unit weight Approx. 80 g 2.820oz Approx. 180 g 6.349oz Approx. 400 g 14.11oz Approx. 600 g 21.16oz Approx. 750 g 26.46oz

Panasonic Corporation Automation Controls Business Unit industrial.panasonic.com/ac/e/ EP (AEP) ASCTB3E 201211-T REFERENCE DATA Note: The switching life curves are rough guides for when using over the nominal values. Be sure to conduct tests with the actual device to verify your specifications. 1.-(1) Ambient temperature characteristics (10A type) Tested sample: AEP31012, 3pcs 1.-(2) Ambient temperature characteristics (20A type) Tested sample: AEP52012, 3pcs 1.-(3) Ambient temperature characteristics (80A type) Tested sample: AEP18012, 3pcs x -40 -40 -30 -20 -10 0-40 146 110 -20 Ambient temperature, °C °F Pick up voltage Drop out voltage Variation ratio, % x Drop out voltage -40 -40 -30 -20 -10 0-40 146 110 -20 Ambient temperature, °C °F Pick up voltage Variation ratio, % Ambient temperature, °C °F -40 -40 -30 -20 -10 -40 146 110 -20 Pick up voltage Drop out voltage Operate time Release time Variation ratio, % 1.-(4) Ambient temperature characteristics (200A type) Tested sample: AEP17012, 3pcs 1.-(5) Ambient temperature characteristics (300A type) Tested sample: AEP19012, 3pcs 2.-(1) Max. value for switching capacity (10A and 20A types) Ambient temperature, °C °F -40 -50 -40 -30 -20 -10 -40 146 110 -20 Pick up voltage Variation ratio, % Drop out voltage Ambient temperature, °C °F -40 -40 -30 -20 -10 -40 146 110 -20 Pick up voltageDrop out voltage Operate time Release time Variation ratio, % 10A type 400V DC, resistive load 20A type 400V DC, resistive load 10 1 100 1000 1000 100 Contact voltage, V Contact current, A 2.-(2) Max. value for switching capacity (80A, 200A and 300A types) 3.-(1) Switching life and cut-off curves (10A type) 3.-(2) Switching life and cut-off curves (20A type) 10 1 100 1000 1000 100 Contact current, A Contact voltage, V 300A type 400V DC, resistive load 80A type 400V DC, resistive load 200A type 400V DC, resistive load 10A Switching and cut-off possible 10A or less Cut-off only above 10A Load: Resistive 400V DC 1,000V DC 600V DC 800V DC 100 1,000 10,000 11 0 100 1,000 Contact current, A Life (cycle) 20A Switching and cut-off possible 20A or less Cut-off only above 20A Load: Resistive 400V DC 1,000V DC 600V DC 800V DC 100 1,000 10,000 11 0 100 1,000 Contact current, A Life (cycle)

Panasonic Corporation Automation Controls Business Unit industrial.panasonic.com/ac/e/ EP (AEP) ASCTB3E 201211-T DIMENSIONS (mm inch) 1. 10A PC board type 3.-(3) Switching life and cut-off curves (80A type) 3.-(4) Switching life and cut-off curves (300A type) 4.-(1) Carrying performance curve (10A and 20A type) Switching and cut-off possible 80A or less Cut-off only above 80A 80A Load: Resistive 600V DC 400V DC 100 1,000 10,000 11 0 100 1,000 800V DC 1,000V DC Contact current, A Life (cycle) Switching and cut-off possible 300A or less Cut-off only above 300A 300A Load: Resistive 1,000V DC 100 1,000 10,000 1 100 1,000 10,000 600V DC 400V DC 800V DC Contact current, A Life (cycle) 10A type (Electric cable 2 mm 11 0 100 1000 105 104 100 1000 Carrying current, A Time, sec 20A type (Electric cable 3 mm 4.-(2) Carrying performance curve (80A, 200A and 300A types) 11 0 100 1000 105 104 100 1000 Carrying current, A Time, sec 300A type (Electric cable 100 mm 200A type (Electric cable 60 mm 80A type (Electric cable 15 mm The CAD data of the products with a CAD Data mark can be downloaded from: http://industrial.panasonic.com/ac/e/ External dimensions 1 2 34.0 31.3 31.6 19.5 (1.0) 0.5 1.4 3.0 2 dia. 2 dia. 4.5 max. 62.4 55.9±0.3 16.5±0.3 9.5±0.3 11.0±0.3 8.6±0.3 45.0 4.5 R2.3 .091 37.9 Coil input terminal 1: Load input terminal (+) 1.339 1.232 1.244 .768 .020 .055 .118 .079 dia. .079 dia. .177 max. 2.457 2.201±.012 .650±.012 .374±.012 1.772 .177 1.492 (.039) Lead-free pre-solder (Su-3.0Ag-0.5Cu) 2: Load input terminal (−) Schematic (Bottom view) PC board pattern (Bottom view) Notes: 1. We recommend through hole plating with land on both sides. 2. Be careful of the insulation distance between land patterns with regards to the circuit voltage you will use. 6:Coil 5:Coil Load sides have polarities (+) and (–). 4-2.45 dia. 4-.096 dia. After doing through hole platingMounting hole 2-4.2 dia. 9.5 16.5 55.9 8.6 19.6 +0.1 +.004 .374 .650 2.201 .339 .772 2-.165 dia. CAD Data Dimension: Less than 10mm .394inch: 10 to 50mm .394 to 1.969inch: Min. 50mm 1.969 inch: General tolerance ±0.3 ±.012 ±0.6 ±.024 ±1.0 ±.039

Panasonic Corporation Automation Controls Business Unit industrial.panasonic.com/ac/e/ EP (AEP) ASCTB3E 201211-T 2. 10A TM type 3. 20A TM type External dimensions 66.8 19.6 19.5 45.0 8.6 Coil input terminal #187 tab, 0.5t Load input terminal (−) #187 tab, 0.5t Load input terminal (+) #187 tab, 0.5t 55.9±0.3 14.1±0.3 4.5±0.2 dia. 11.3±0.3 37.9 31.7 5.7 0.4 45 max. 31.6 2.630 .772 .768 1.772 .339 2.201±.012 .555±.012 .000±.008 dia. .445±.012 1.492 1.248 .224 .016 1.772 max. 1.244 Schematic (Top view) Panel cut-off 5:Coil Load sides have polarities (+) and (–). 6:Coil Mounting hole 2-4.2±0.1 dia. 55.9±0.1 2.201±.004 2-.165±.004 dia. CAD Data Dimension: Less than 10mm .394inch: 10 to 50mm .394 to 1.969inch: Min. 50mm 1.969 inch: General tolerance ±0.3 ±.012 ±0.6 ±.024 ±1.0 ±.039 External dimensions

78.0 Coil terminal (no polarity)

#250 tab, 0.8t1-Load input terminal (+) #250 tab, 0.8t 2-Load input terminal (–) #250 tab, 0.8t 3.071 50.0 1.969 22.8 .898 19.0 .748 40.0 1.575 11.1 .437 37.0±1.0 1.457±.039 5.8 .228 2-6 dia. 2-.236 dia. 22.5 .886 9.2 .362 64.0 2.520 Schematic (Top view) Panel cut-off Coil Load sides have polarities (+) and (–). Coil 64.0±0.1 2.520±.004 Mounting hole 2-6.0±0.2 dia. 2-.236±.008 dia. CAD Data Dimension: Less than 10mm .394inch: 10 to 50mm .394 to 1.969inch: Min. 50mm 1.969 inch: General tolerance ±0.3 ±.012 ±0.6 ±.024 ±1.0 ±.039

Panasonic Corporation Automation Controls Business Unit industrial.panasonic.com/ac/e/ EP (AEP) ASCTB3E 201211-T 4. 80A Connector type 5. 200A Lead wire type External dimensions .394 10.0 7.3 .287 3.110 79.0 75.5 2.972 2: Load input terminal (−) 1: Load input terminal (+) .276 26.0±0.3 1.024±.012 7.3 .287 63.5±0.3 2.500±.012 (.705) (17.9) Color height 5.7 .224 .079 M5 bolt .236 dia. 6 dia. 2.280 57.9 (ends of bus bar) .626 15.9 (width of bus bar) 1.768 44.9 (M5 bolt pitch) 1.772 (connector position) 8.0 .315 dia. (flat w asher) 69.0 2.71775.0 2.953 40.0 1.575 (M4) Connector Part No.: 7282-1020 (Y azaki)* .472 Schematic (Top view) Panel cut-off *Accessories (included) Coil Coil 1+2− Load sides have polarities (+) and (−). 2-.236±.004 dia. 2-6±0.1 dia. 63.5±0.1 2.500±.004 26±0.1 1.024±.004 (5) (.197) 300±10 11.811±.394 0.5sq/Green 0.5sq/White Female connector (non-waterproof type), Y azaki 7283-1020 CAD Data Dimension: Less than 10mm .394inch: 10 to 50mm .394 to 1.969inch: Min. 50mm 1.969 inch: General tolerance ±0.3 ±.012 ±0.6 ±.024 ±1.0 ±.039 Load input terminal (+) Load input terminal (−) Coil connection lead wire (no polarity) >PBT-GF30 FR(17)< 1.063 27.0 2-.236 2-6.0 2.126 54.0 (.083) (2.1) .224 5.7 (Color height) M6 female screw (.079) (2.0) 2.638 67.0 3.228±.012 82.0±0.3 3.740 95.0 7.874±.787 200±20 1.110 28.2 1.772 45.0 1.220±.012 31.0±0.3 2.953 75.0 .020 0.5 3.402 86.4 Accessories Two hexagonal bolts (M6 × 12 mm .472 inch) with flat washers are included. External dimensions Schematic (Top view) Panel cut-off Coil Coil + − Load sides have polarities (+) and (−). 2-.236±.004 dia. 2-6±0.1 dia. Mounting hole3.228±.004 82±0.1 1.220±.004 31±0.1 CAD Data Dimension: Less than 10mm .394inch: 10 to 50mm .394 to 1.969inch: Min. 50mm 1.969 inch: General tolerance ±0.3 ±.012 ±0.6 ±.024 ±1.0 ±.039

Panasonic Corporation Automation Controls Business Unit industrial.panasonic.com/ac/e/ EP (AEP) ASCTB3E 201211-T 6. 300A Connector type SAFETY STANDARDS NOTES Product name UL/C-UL (Recognized) File No. Contact rating 10A E43149 10A 400V DC, 10A 277V AC Resistive 20A E43149 20A 400V DC, 20A 277V AC Resistive 80A E43149 80A 400V DC, 80A 277V AC Resistive External dimensions 2-1+ (13) (.512) 39.3 1.547 74.7 2.941 .224 5.7 48.7 1.917 24.5 .965 .118 5: Coil terminal (V+) 2.429 61.7 M8 Flange nut 6: Coil terminal (GND) 1: Load input terminal (+) 2: Load input terminal (−) 2.480 2.362 47±0.3 1.850±.012 1.063 111 79±0.3 1.063 4.370 3.622 3.386 3.110±.012 1.732 3-.236 dia.3-6 dia. 73.4 2.890 M8 bolt Connector Part No.: 7282-1020 (Y azaki)* Schematic (Top view) Panel cut-off *Accessories (included) 6: Coil (GND) 5: Coil (V+) 2−1+ Input and load sides have polarities (+) and (−). 79±0.1 3.110±.004 47±0.1 1.850±.004 3-6±0.1 dia. 3-.236±.004 dia. (5) (.197) 300±10 11.811±.394 0.5sq/Green(GND) 0.5sq/White(V+) Female connector (non-waterproof type), Y azaki 7283-1020 CAD Data Dimension: Less than 10mm .394inch: 10 to 50mm .394 to 1.969inch: 50 to 100mm 1.969 to 3.937 inch: Min. 100mm 3.937 inch: General tolerance ±0.3 ±.012 ±0.6 ±.024 ±1.0 ±.039 ±1.6 ±.063 1. Please read “GENERAL APPLICATION GUIDELINES” for regular cautionary items. 2. When installing the relay, always use washers to prevent the screws from loosening. Tighten each screw within the rated range given below. Exceeding the maximum torque may result in breakage. Mounting is possible in either direction.

  • M5 screw (20A, 80A, 200A and 300A main unit mounting section): 3 to 4N·m
  • M4 screw (10A PC board type main unit mounting section): 0.98 to 1.2N·m (10A TM type main unit mounting section): 1.8 to 2.7N·m Recommended securing torque on load side terminals
  • 80A/M5 bolt: 3.5 to 6.5 N·m
  • 200A/M6 bolt: 6 to 8 N·m
  • 300A/M8 bolt: 10 to 12 N·m 3. The contacts of the relay are polarized. Please follow instructions in the connection schematic when connecting the contacts. We recommend installing a surge protector varistor for the 10A, 20A, 80A and 200A types. Please note that when using a diode, the switching speed may decrease and cause a reduction in cut-off performance. For the 300A type, separate surge countermeasures are not required, because it contains a built-in surge absorbing element. <Recommend varistor> Amount of proof energy: Min. 1 J Varistor voltage: 1.5 to 3.0 times of nominal voltage 4. Do not use a relay if it has been dropped. 5. Avoid mounting the relay in strong magnetic fields (near a transformer or magnet) or close to an object that radiates heat. 6. Electrical life This relay is a DC high-voltage switch. In its final breakdown mode, it may lose the ability to provide the proper cut-off. Therefore, do not exceed the indicated switching capacity and life. (Please treat the relay as a product with limited life and replace it when necessary.) In the event that the relay loses cut-off ability, there is a possibility that burning may spread to surrounding parts, so configure the layout so that the power is turned off within one second and from the point of view of safety, consider installing a failsafe circuit in the device. Also, in order to avoid increased contact resistance, do not operate when there is no switching load.

Panasonic Corporation Automation Controls Business Unit industrial.panasonic.com/ac/e/ EP (AEP) ASCTB3E 201211-T 7. Permeation life of internal gas This relay uses a hermetically encased contact (capsule contact) with gas inside. The gas has a permeation life that is affected by the temperature inside the capsule contact (ambient temperature + temperature rise due to flow of electrical current). Therefore, please do not exceed the operation ambient and storage ambient temperatures given in the specifications. 8. Do not disassemble the relay. Please note that disassembling the relay will invalidate the warranty. 9. If the power is turned off and then immediately on after applying the rated voltage (current) continuously to the relay’s coil and contact, the resistance of the coil will increase due to a rise in the coil temperature. This causes the pick-up voltage to rise, and possibly exceed the rated pick-up voltage. In these circumstances, take measures such as reducing the load current, limiting the duration of current flow, and applying a coil voltage higher than the rated operating voltage. 10. Pure DC current should be applied to the coil. If it includes ripple, the ripple factor should be less than 5%. However, check the actual circuit since the characteristics may be slightly different. The power supply waveform supplied to the coil should be rectangular. Also, the 300A type has a built-in dedicated drive circuit. It may not operate normally unless the rise time is 10 ms or less. 11. Don’t exceed maximum coil voltage. Exceeding maximum allowable coil voltage on continuous basis will damage the relay and could case failure. 12. If you will be using with a load voltage that exceeds 400 V DC, please be sure to verify operation on the actual device, referring to the switching life curves (reference data). You must absolutely avoid continual use in which the load current exceeds the rated value. This will cause abnormal heating. 13. The rated control capacity and life are given as general guides. It is important to conduct sufficient tests on the actual device, because contact properties and working life will differ considerably depending on the type of load and conditions. 14. Main contact ratings in the ratings apply to when there is a resistive load. If you are using an inductive load (L load) such that L/R > 1 ms, add surge protection in parallel with the inductive load. If this is not done, the electrical life will decrease and cut-off failure may occur. In order to prevent contact welding when using a capacitive load (C load) such as a capacitor load, please make the inrush current setting more than two times that of the nominal current. Please contact us for more information. 15. Be careful that foreign matter and oils and fats kind don’t stick to the main terminal parts because it is likely to cause terminal parts to give off unusual heat. Also, please use the following materials for connected harnesses and bus bars. 10A TM type: #187, 0.5 mm board thickness 20A TM type: #250, 0.8 mm board thickness tab terminal (JIS C289-1999 compliant, flat type connection terminal) Harness nominal cross-sectional area Load input terminal side; 10A TM type: min. 2.0 mm 20A TM type: min. 3.0 mm2 Coil input terminal side; 10A and 20A TM types: min. 0.3 mm 80A type: min. 15 mm2 200A type: min. 60 mm2 300A type: min. 100 mm2 16. Use 40 to 70N or 50 to 80N of force as a guide to fasten the terminal connected to the 10A TM and 20A TM types. Please use caution when inserting or removing the terminal as the relay tab terminal may cause injuly. Also, unstable conductivity and abnormal terminal heating may occur; therefore, please check that there is no deformation of or foreign objects on the faston terminals (blade receptacle) you will be connecting. Use JIS C2809 (or IEC60760) certified products. 17. Place the PC board mount type (10A PC board type) securely by hand soldering after attaching it using M4 screw. Don’t submerge assembled board in cleaning solvent or water. Also, be careful not let flux overflow up from the PC board or adhere to the base of the relay. Recommended hand soldering conditions

  • Soldering iron: 30 to 60 W
  • Tip temperature: 400°C 752°F
  • Solder time: within approx. 5 seconds 18. Make sure the power is turned off when wiring. 19. Incorrect wiring may cause unexpected malfunction and failure. 20. Regarding AC cutoff, although there is no contact polarity, generally it is thought that the electrical life will shorten due to cutoff in the reverse direction, compared to DC cutoff. Confirm electrical life using actual load. In the case of DC cut-off, please note the contact polarity. 21. Lead-free solder (tin, silver and copper) is used as pre-solder for the terminals of the PC board mount type (10A PC board type). 22. The warranted tensile strength of the female connector lead wire used for connection that comes with the 80A and 300A connector type when attaching it to the relay body is 98N. Avoid excessive tension as this is a cause of broken wires and damage. Also, insert the female connector deeply and make sure the connection is secure. 23. Condensation will occur during sudden temperature changes in hot and humid environments. Caution is required, because condensation will cause a decrease in the insulation resistance between the terminals.