38.0 1.496 29.0 1.142 17.3 .681
FEATURES
- Compact with high capacity Although compact this relay can handle high capacity control of 30A. 2. Latching type With latching this relay contributes to en- ergy conservation in devices. 3. High insulation Designed with an insulation distance of at least 8 mm. 4. Cadmium and lead free 5. Complies with safety standards UL, CSA and VDE approved. SPECIFICATIONS Contact Coil Arrangement 1 Form A Initial contact resistance, max. (By voltage drop 6 V DC 1 A) 30 m W Contact material Silver alloy Rating (resistive load) Nominal switching capacity 30 A 250V AC Max. switching power 7,500 V A Max. switching voltage 250V AC Max. switching current 30 A Expected life (min. operations) Mechanical (at 180 cpm) 10 Electrical (Resistive load) 10 Nominal operating power 1 coil latching 800 mW 2 coil latching 1,600 mW Characteristics Max. operating speed (at rated load) 180 cpm Initial insulation resistance* Min. 1,000 M W (at 500 V DC) Initial breakdown voltage* Between open contacts 1,500 Vrms for 1 min. Between contacts and coil 4,000 Vrms for 1 min. Surge voltage between contact and coil* Min. 10,000 V (initial) Operate time [Set time]* (at 20 (at nominal voltage) Max. 20ms Release time [Reset time]* (at 20 (at nominal voltage) Max. 20ms Temperature rise (at 65 C)* Max. 50 C Shock resistance Functional* Min. 200 m/s {20 G} Destructive* Min. 1,000 m/s {100 G} Vibration resistance Functional* 10 to 55Hz at double amplitude of 1.5mm Destructive 10 to 55Hz at double amplitude of 2.0mm Conditions for operation, transport and storage* (Not freezing and condensing at low temperature) Ambient temperature* –40 C to +65 C –40 F to +149 F Humidity 5 to 75% R.H. Unit weight Approx. 35 g 1.23 oz Remarks * Specifications will vary with foreign standards certification ratings. At nominal switching capacity, operating frequency: 3s ON, 3s OFF Measurement at same location as "Initial breakdown voltage" section. Detection current: 10mA Wave is standard shock voltage of 1.2 m s according to JEC-212-1981 Excluding contact bounce time. By resistive method, max. switching current Half-wave pulse of sine wave: 11 ms; detection time: 10 m s Half-wave pulse of sine wave: 6 ms Detection time: 10 m s Refer to 5. Usage, transport and storage conditions mentioned in NOTES Under the packing condition, allowable temperature range is from –40 to +65 C –40 to +149 TYPICAL APPLICATIONS
- Time switches
- Electric water heaters
- Remote control of electric power meters dq.fm 1 y [ W QOOPNPQ PPú@Îjú@ ãR ROª
ORDERING INFORMATION
Operating function Contact capacity 1: 1 coil latching 2: 2 coil latching 3: 30 A Terminal shape Q: 250 Faston terminal Contact characteristics 0: Standard contact Coil voltage (DC) 4H: 4.5 V 06: 6 V 09: 9 V 12: 12 V 24: 24 V ADQ 3Q0 TYPES AND COIL DATA (at 20 C 68
- 1 coil latching type
- 2 coil latching type Contact arrangement Part No. Nominal voltage, V DC Set voltage, max. V DC (initial) Reset voltage, max. V DC (initial) Coil resistance, W 10%) Nominal operating current, mA 10%) Nominal operating power, mW Max. allowable voltage, V DC
1 Form A
ADQ13Q006 6 4.2 4.2 45 133.3 800 7.8 ADQ13Q009 9 6.3 6.3 101 88.9 800 11.7 ADQ13Q012 12 8.4 8.4 180 66.7 800 15.6 ADQ13Q024 24 16.8 16.8 720 33.3 800 31.2 Contact arrangement Part No. Nominal voltage, V DC Set voltage, max. V DC (initial) Reset voltage, max. V DC (initial) Coil resistance, W 10%) Nominal operating current, mA ( 10%) Nominal operating power, mW Max. allowable voltage, V DCSet coil Reset coil Set coil Reset coil Set coil Reset coil General tolerance: 0.3 .012 38.0 1.496 0.8 .031 0.8 .031 0.8 .031 5.08 .200 10.16 .400 20.32 .800 0.8 .031 3.6 .142 250 faston terminal 35.8 1.4096.35 .250 0.4 .016 0.4 .016 1.5 .059 1.8 .071 25.4 1.000 5.08 .200 5.08 .200 1.5 .059 3.3 dia. .130 dia. 1.7 dia. .067 dia. 29.0 1.142 40.1 1.579 4.5 .177 3.7 .146 17.3 .681 0.3 .012 21.4 .843 7.9 .311 6.9 272 Schematic (Bottom view) Note) Terminal No.3 is only for 2 coil latching type. PC board pattern (Bottom view) Tolerance: 0.1 .004 Reset coil Set coil – 4 3–2 10.16 .400 15.24 .600 5.08 .200 5.08 .200 5.08 .200 4-2.0 dia.4-.079 dia. 3-1.5 dia. 3-.059 dia. 25.4 1.000 dq.fm 2 y [ W QOOPNPQ PPú@Îjú@ ãR ROª
- Coil operating power Pure DC current should be applied to the coil. The wave form should be rectangular. If it includes ripple, the ripple factor should be less than 5%. However, check it with the actual circuit since the characteristics may be slightly different. 2. Coil connection When connecting coils, refer to the wiring diagram to prevent mis-operation or mal- function. 3. Soldering We recommend the following soldering conditions Soldering: 300 C 572 F, max. 5 s 4. Others 1) If the relay has been dropped, the ap- pearance and characteristics should al- ways be checked before use. 2) The cycle lifetime is defined under the standard test condition specified in the JIS* C 5442-1996 standard (temperature 15 to 35 C 59 to 95 F, humidity 25 to 75%). Check this with the real device as it is affected by coil driving circuit, load type, activation frequency, activation phase,ambient conditions and other fac- tors. Also, be especially careful of loads such as those listed below. (1) When used for AC load-operating and the operating phase is synchronous. Rocking and fusing can easily occur due to contact shifting. (2) High-frequency load-operating When high-frequency opening and clos- ing of the relay is performed with a load that causes arcs at the contacts, nitrogen and oxygen in the air is fused by the arc energy and HNO is formed. This can cor- rode metal materials. Three countermeasures for these are listed here. 1. Incorporate an arc-extinguishing cir- cuit. 2. Lower the operating frequency 3. Lower the ambient humidity 3) For secure operations, the voltage ap- plied to the coil should be nominal volt- age. In addition, please note that pick-up and drop-out voltage will vary according to the ambient temperature and operation conditions. 4) Heat, smoke, and even a fire may occur if the relay is used in conditions outside of the allowable ranges for the coil ratings, contact ratings, operating cycle lifetime, and other specifications. Therefore, do not use the relay if these ratings are ex- ceeded. Also, make sure that the relay is wired correctly. 5) Incorrect wiring may cause unexpected events or the generation of heat or flames. 6) Check the ambient conditions when storing or transporting the relays and de- vices containing the relays. Freezing or condensation may occur in the relay, causing functional damage. Avoid sub- jecting the relays to heavy loads, or strong vibration and shocks. 5. Usage, transport and storage condi- tions 1) Ambient temperature, humidity, and at- mospheric pressure during usage, trans- port, and storage of the relay: (1) Temperature: –40 to +65 C – 40 to +149 F (2) Humidity: 5 to 75% RH (Avoid freezing and condensation.) The humidity range varies with the tempera- ture. Use within the range indicated in the graph below. (3) Atmospheric pressure: 86 to 106 kPa Tem- perature and humidity range for usage, trans- port, and storage: 2) Condensation Condensation forms when there is a sud- den change in temperature under high temperature and high humidity conditions. Condensation will cause deterioration of the relay insulation. 3) Freezing Condensation or other moisture may freeze on the relay when the tempera- tures is lower than 0 C 32 F. This causes problems such as sticking of movable parts or operational time lags. 4) Low temperature, low humidity environ- ments The plastic becomes brittle if the relay is exposed to a low temperature, low humid- ity environment for long periods of time. /,/,/, /,/,/,/,/, /,/,/,/,/,/,/, /,/,/,/,/,/,/,/,/, Humidity, %RH Temperature, °C °F Tolerance range +32 +119 –40 –40 (Avoid condensation when used at temperatures higher than 0°C 32°F) (Avoid freezing when used at temperatures lower than 0°C 32°F) 12/1/2001 All Rights Reserved, © Copyright Matsushita Electric Works, Ltd. Go To Online Catalog dq.fm 3 y [ W QOOPNPQ PPú@Îjú@ ãR ROª