DATASHEET SEARCH SITE | WWW.ALLDATASHEET.COM
Document overview
- Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
- PDF pages: 5
Technical content
ADP Series Power Adapters 19V 40W/65W/90W www.DeltaPSU.com (January 2016, Rev. 1.0) ADP 19V Highlights & Features – Energy Star Compliance (Level VI) – IT safety approvals – 100k Hours MTBF – Over-Voltage/Load/Temperature & Short Circuit protections – Low Leakage Current Safety Standards CB Certified for worldwide use Model Information ADP Series Power Adapters Model Number Input Voltage Range Output Voltage Output Current ADP-40KD BBBM 90-264Vac 19Vdc 2.1A ADP-65JH HBAN 90-264Vac 19Vdc 3.42A ADP-90MD HDM 90-264Vac 19Vdc 4.74A Specifications Input Ratings / Characteristics ADP-‐40KD BBBM ADP-‐65JH HBAN ADP-‐90MD HDM
ADP Series Power Adapters 19V 40W/65W/90W www.DeltaPSU.com (January 2016, Rev. 1.0) Output Ratings / Characteristics ADP-‐40KD BBBM ADP-‐65JH HBAN ADP-‐90MD HDM Rise Time DC output rise time from 10% to 90% of output voltage shall be less than 30mS at nominal line and maximum load DC output rise time from 10% to 90% of output voltage shall be less than 100ms at nominal line and maximum load Transient Load Response 0.1A to 100% load at 2.5A/us slew rate and frequency is 10Hz to 10KHz 0% to 50% and 50% to 100% 1.0A/us slew rate and frequency is 100Hz Environment ADP-‐40KD BBBM ADP-‐65JH HBAN ADP-‐90MD HDM Operating Temperature 0 °C to +40 °C Shipping/Storage Temperature -30 °C to +80 °C -20 °C to +85 °C. Operating Humidity 8% to 90% RH (Non-Condensing) Shipping/Storage Humidity 5% to 95% RH (Non-Condensing) Lightning Surge Immunity IEC-1000-4-5 Level 3 Requirements L-N 1KV/1.2 * 50uS 5 times No damage IEC-61000-4-5 Level 3 requirements L-N 1KV/1.2 * 50uS 5 times No function error L-FG 2KV/1.2 * 50uS 5 times No damage. Electric Fast Transients (EFT) IEC-1000-4-4/1995 EN 61000-4-4 Electrostatic Discharge (ESD) ±15KV air discharge ±8KV contact discharge Dielectric Withstand Voltage (HI-POT) Between AC input and secondary AC 3KV test time 1 minute; 100% of line products of this Adapter shall be applied 3000Vac for 2 seconds between AC input terminals and output terminals. Cut off current 3mA. Between AC input and secondary AC 3KV test time 1 minute; 100% of line products of this Adapter shall be applied 3000Vac for 2 seconds between AC input terminals and output terminals. Cut off current 10mA. 100% of line products of this Adapter shall be applied 3000Vac for 1 seconds between AC input terminals and output terminals. Cut off current is 10mA. Insulation Resistance The insulation resistance shall be not less than 30M ohms after application of 500Vdc/10mA for 1 minute. The insulation resistance shall be not less than 20M ohms after application of 500Vdc/10mA for 1 minute Electromagnetic Interference (EMI) (a) FCC Class B (b) CISPR 22 Class B (c) VCCI Class B (a) FCC Class B (b) CISPR 22 Class B (c) VCCI Class B (a) FCC Class B (b) CISPR 22 Class B (c) VCCI Class B MTBF 150,000 hours 100,000 hours Altitude 5,000m (16,400 ft)
ADP Series Power Adapters 19V 40W/65W/90W www.DeltaPSU.com (January 2016, Rev. 1.0) Protections ADP-‐40KD BBBM ADP-‐65JH HBAN ADP-‐90MD HDM Over Voltage The output shall be protected to latch off at over-voltage condition, maximum value can’t be over 29V. The output shall be protected to latch off at over-voltage condition, maximum value can’t be over 27V. The output shall be protected to latch off at over-voltage condition, maximum value shall be more than 22V and be less than 27V. Overload / Overcurrent The maximum constant current shall be more than 2.1A and be less than 5.0A at 90Vac and 264Vac. The adaptor shall be auto-recovery. The maximum constant current shall be more than 4.1A. The adapter shall be Auto-recovery Mechanical ADP-‐40KD BBBM ADP-‐65JH HBAN ADP-‐90MD HDM
ADP Series Power Adapters 19V 40W/65W/90W www.DeltaPSU.com (January 2016, Rev. 1.0) MechanicalADP-40KD BBM ADP-65JH HBAN
ADP Series Power Adapters 19V 40W/65W/90W www.DeltaPSU.com (January 2016, Rev. 1.0) ADP-90MD HDM