Technical content
ADP Series Power Adapters 12V 25W/36W/66W TECHNICAL DATASHEET ADP 12V Highlights & Features – Energy Star Compliance (Level VI) – IT safety approvals – 100k Hours MTBF – Over-Voltage/Load/Temperature & Short Circuit protections Model Information ADP Series Power Adapters Model Number Input Voltage Range Output Voltage Output Current ADP-25FW BB 90-264Vac 12Vdc 2.1A ADP-36PH BH 90-264Vac 12Vdc 3A ADP-66CR BE 90-264Vac 12Vdc 5.5A Specifications Input Ratings / Characteristics 25W 36W 66W Nominal Input Voltage 115/230Vac 100-240Vac 115/230Vac Input Voltage Range 90-264 Vac Nominal Input Frequency 50-60Hz Input Frequency Range 47-63Hz Input Current 1A Max @ 100Vac 600mA @ 240Vac 1A Max at 100Vac input voltage 2A Max at 100Vac input voltage Inrush Current(Cold Start) <50A at 120VAC No Damage at 240Vac <90A at 230Vac Efficiency at nominal input voltage 86% @ 115Vac 84% min, max load and measured at the end of DC cable. 83%
ADP Series Power Adapters 12V 25W/36W/66W TECHNICAL DATASHEET Output Ratings / Characteristics 25W 36W 66W Turn On delay time 2 seconds @ 120Vac 5 seconds @ 100-240Vac 3 seconds @ 90Vac/60Hz and -0°C to +45°C; OR 10 seconds at -20°C to 0°C. Rise Time <20ms 30mS 30ms Max Load Capacitance (microfarads) 1000 470 1000 Load Transient Response 0%-50%-0% and 50%-100%-50% of full nominal load. frequency is 60Hz, 50% duty cycle and the slew rate shall be at 0.02A/us. 25W 36W 66W Operating Temperature 0 °C to +40 °C -20 °C to +45 °C Electric Fast Transients (EFT) EN61000-4-4 +/-1kV on input power lines; Criterion B I EC-1000-4-4/1995 (EN 61000-4-4) Level 3 requirements EN61000-4-4 +/-1kV on input power lines; Criterion B Electrostatic Discharge (ESD) Per IEC-61000-4-2 Contact discharge:±8KV Air discharge:±15KV +/-8kV air discharge; +/-6kV contact discharge; Dielectric Withstand Voltage (HI-POT) 3KV AC RMS from AC Input to Output Leakage Current <250uA at 264 Vac <100uA at 240Vac/50Hz <250uA at 264 Vac Insulation Resistance The insulation resistance shall be not less than 4M ohms after application of 500Vdc/10mA for 1 minute. The insulation resistance shall be not less than 30M ohms after application of 500Vdc/10mA for 1 minute. The insulation resistance shall be not less than 10M ohms after application of 500Vdc/10mA for 1 minute. Electromagnetic Interference (EMI) CISPR 22/EN55022 Class B. (a) FCC Class B (b) CISPR 22 Class B (c) VCCI Class B CISPR 22 : 1997/EN55022(1998) Class B. MTBF 200,000 hours of continuous operation at 25℃ 80,000 hours of continuous operation at 25℃ 150,000 hours of operation at 90% confidence level at 25degC Electrolytic Capacitor Operating Life 7 years at 115VAC, 40C and 100% rated load 3 years at 115 Vac and 230 Vac, and 25degC 100% rated load 5 years at 115 Vac and 230 Vac, and 25degC 100% rated load
ADP Series Power Adapters 12V 25W/36W/66W TECHNICAL DATASHEET Protections 25W 36W 66W Overvoltage <150% of nominal output voltage (Recovery mode) Latch Mode Latch Mode Overload / Overcurrent <150% maximum load current (Recovery mode) Auto-Recovery Auto-Recovery Over Temperature Recovery mode Latch Mode Auto-Recovery Short Circuit Recovery mode Auto-Recovery Auto-Recovery Mechanical 25W 36W 66W
ADP Series Power Adapters 12V 25W/36W/66W www.DeltaPSU.com (January 2016, Rev. 1.0) ADP-36PH BH ADP-66CR BE