ADN2.5-24-1PM ASTEC | Alldatasheet

Document overview

  • Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
  • PDF pages: 2

Technical content

rev 09.08.05 Technical Support: (888) 41ASTEC or (407) 241-2752 Americas: (760) 930-4600 Europe (UK) 44 (1384) 842-211 Asia (HK) 852-2437-9662 190 Special Features 60-480 Watts ADN Series Electrical Specs

  • Power Factor Correction
  • Auto Select 115/230 VAC, 50/60 Hz Input
  • All Single Phase models meet SEMI F47 Sag Immunity
  • Class 1, Div 2 Hazardous Locations
  • DC OK Signal
  • Adjusable Voltage
  • Industrial grade design (no derating to 60°C)
  • User-friendly front panel
  • Single and three phase inputs available
  • Highly efficent >90% switching technology
  • High MTBF and reliability
  • Peak current capability 2x rated current for 2 seconds
  • Three year warranty
  • NEC Class 2 on models <100W Input Nominal voltage 115/230 VAC auto select Power factor (PFC) EN61000-3-2 AC Input range 85-123 / 176-264VAC DC Input range 210-375VDC Frequency 47-63 Hz, 500 Hz Output Nominal voltage 24V (22.5-28.5VDC Adj.) Holdup time > 20ms at full load (25°C) Tolerance < ±2 % overall (combination line/load/time/temp) Tolerance < ±2 % overall Line regulation <0.5% Load regulation <0.5% Time & temp. drift <1% Initial voltage setting 24.5V ± 1% Ripple < 50mVpp Power back immunity > 35V Parallel Operation ADN20-24-1PM Switch selectable All others Jumper selectable via front panel Over voltage protection < 33VDC Storage/Shipment -25°C to +85°C Operating (convection) -10° C to +60° C (derate to 50% at +70° C) Humidity <90% RH noncondensing per IEC 68-2-2, 68-2-3 IP20 (EN60529), protection from moisture & condensation EMC Emissions EN 61000-6-3, Class B EN55011, EN55022 Radiated Conducted including Annex A Immunity EN 61000-6-2, EN61000-4-2 Level 4, EN61000-4-3 Level 3, EN61000-4-6 Level 3, EN61000-4-4 Level 4 input and level 3 output. EN61000-4-5 Isolation class 4, EN61000-4-11, Transient protection according to VDE 0160/W2 over entire load range. Approvals EN60950, UL508 Listed, cULus, UL 60950, cURus, CE EN61000-3-2, EN60079-15 (Class 1, Division 2 hazardous location, Groups A, B, C, D w/ T3 temp class up to 60°C Ambient.) SEMIF47 Sag Immunity. For models <100W, UL60950 testing to include approval as NEC Class 2 power supply acc. To NFPA 70 Protection Class 1 (IEC536), degree of protection SELV rated per EN60950 Environmental Safety Total Power: 60 - 480 Watts Input Voltage: 115/230 VAC # of Outputs: One

Astec House, Waterfront Business Park Merry Hill, Dudley West Midlands, DY5 1LX, UK Telephone: 44 (1384) 842-211 Facsimile: 44 (1384) 843-355 AMERICAS

5810 Van Allen Way

Carlsbad, CA 92008 Telephone: 760-930-4600 Facsimile: 760-930-0698 191www.astecpower.com

Ordering Information

Units 2111-2116, Level 21 Tower1, Metroplaza 223, Hing Fong Road Kwai Fong, New Territories Hong Kong Telephone: 852-2437-9662 Facsimile: 852-2402-4426 Model Weight Power Voltage Current Case Type ADN2.5-24-1PM 1.6 lbs. (725g) 60W 85-264VAC 2.5A metal 90-375VDC ADN4-24-1PP 0.7 lbs. (320g) 93W 85-132 / 176-264VAC 3.8A plastic 210-375VDC ADN4-24-1PM 2.4 lbs. (1055g) 100W 85-132 / 176-264VAC 4A metal 210-375VDC ADN5-24-1PM 2.4 lbs. (1055g) 120W 85-132 / 176-264VAC 5A metal 210-375VDC ADN10-24-1PM 3.3 lbs. (1480g) 240W 85-132 / 176-264VAC 10A metal 210-375VDC ADN20-24-1PM 3.4 lbs. (1520g) 480W 85-132 / 176-264VAC 20A metal DIMENSIONS(inches) Height Width Depth ADN2.5-24-1PM 4.88 1.97 4.55 ADN4-24-1PP 2.95 2.85 3.80 ADN4-24-1PM 4.88 2.56 4.55 ADN5-24-1PM 4.88 2.56 4.55 ADN10-24-1PM 4.88 3.26 4.55 ADN20-24-1PM 4.88 6.88 4.66 ADN2.5 thru ADN10 ADN20