ADC400 MPSIND | Alldatasheet

Document overview

  • Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
  • PDF pages: 2

Technical content

VDC VDC % Typ. % Max. ADC401 5 66 10 ADC402 12 66 8 ADC403 15 66 8 ADC404 ±5 66 10 ADC405 ±12 72 8 ADC406 ±15 73 8 ADC411 5 66 10 ADC412 12 66 8 ADC413 15 66 8 ADC414 ±5 66 10 ADC415 ±12 74 8 ADC416 ±15 75 8 Pin Singles Duals 1 +Vin +Vin 2 -Vin -Vin 5 -Vout -Vout

6 No Pin Common

Tolerance Millimeters Inches X.X±0.25 X.XX±0.01 X.XX±0.13 X.XXX±0.005 Pin ±0.05 ±0.002 2463 208th Street, Ste. 205 http://www.mpsind.com Torrance, CA 90501 E-mail: sales@mpsind.com MPS Industries ADC400 1W DC/DC's are specially designed to provide ultra-high levels of isolation 6000VDC in a miniature SIP package. The series consists of 12 models with input voltages of 5V and 12VDC which offers standard output voltages of 5V, 12V, 15VDC in both single and dual output configurations. The ADC400 series is an excellent selection for a variety of applications including distributed power systems, mixed analog/digital subsystems, portable test equipments, local power networks and battery backed systems. 3.9g (0.14Oz) Case Size – Pin Connections Mechanical Dimensions Tel: (310) 533-1455 Fax: (310) 533-1853 Weight – 1W, Ultra-High Isolation SIP, Single & Dual Output DC/DC Converters Case Material – Non-Conductive Black Plastic ±40 mA 200 ±35 200 ±100 ±100 (4.5 - 5.5) (10.8 - 13.2) Key Features

  • Efficiency up to 75%
  • 6000VDC Isolation
  • MTBF > 2,000,000 Hours
  • Internal SMD Construction
  • Industry Standard Pin-out
  • Input 5 and 12VDC
  • Output 5, 12, 15, ±5, ±12 and ±15VDC
  • Temperature Performance -25°C to +70°C
  • UL 94V-0 Package Material
  • Low Cost Selection Guide Model Number Input Voltage Output Voltage Efficiency Load Regulation Output Current ±40 ±35 12.5 [0.49] 3.5 [0.14] 3.5 [0.14] 2.0 [0.08] 7.5 [0.30] 21.0 [0.83] 12 7 56 0.50 [0.020] 0.5 [0.02] 22.0 [0.87] 2.54 [0.100] 0.25 [0.010]

5VDC Input Models -0.7 9 VDC Isolation Voltage 6000 --- --- VDC 12VDC Input Models -0.7 18 VDC Isolation Resistance 10 --- --- G Ω --- 260 °C Isolation Capacitance --- 15 20 pF --- 650 mW Switching Frequency 50 80 100 kHz Operating Temperature Ambient -25 70 °C Line Regulation --- ±1.2 ±1.5 % Operating Temperature Case -25 90 °C Load Regulation % Storage Temperature -40 125 °C Ripple & Noise --- 100 150 mV P-P Humidity --- 95 % Short Circuit Cooling Units uF 2463 208th Street, Ste. 205 http://www.mpsind.com Torrance, CA 90501 E-mail: sales@mpsind.com Tel: (310) 533-1455 Fax: (310) 533-1853 --- MHrs Environmental Characteristics Free-Air Convection Output Characteristics See Selection Guide 0.5 Second Max. 1W, Ultra-High Isolation SIP, Single & Dual Output DC/DC Converters Absolute Maximum Ratings Parameter Input Surge Voltage (1000mS) Conditions

60 Seconds

(1.5mm from case for 10sec.) Internal Power Dissipation Exceeding the unit absolute maximum ratings could cause damage. These are not continuous operating ratings. --- 100kHz, 1V 20MHz BW MTBF 2 Maximum Capacitive Load MIL-HDBK-217F @25°C Ground Benign Conditions For Vin Change of Io = 20% to 100% Models by Output Voltage (Each Output on Duals) Notes: 1. Specifications typical at Ta=+25°C, resistive load, nominal input voltage, rated output current unless otherwise noted. 2. These power converters require a minimum output load to maintain specified regulation. 3. Operation under no-load conditions will not damage these modules; however, they may not meet all specifications listed. 4. All DC/DC converters should be externally fused at the front end for protection. 5. Other input and output voltage may be available, please contact factory. 6. All specifications subject to change without notice. 7. For detailed data sheet, please visit our website. Derating Curve Singles Duals 680 220 ]Ambient Temperature Output Power (%) 100 -25 50 60 80 100 110 9070 400LFM 200LFM 100LFM Natural convection