Features
1 Form A / 1 Form B Integrated in 1 Package Low Input Control Current (1.5mA TYP) 150mA Maximum Continuous Load Current Low On Resistance (25 MAX – Both Poles) High Isolation Voltage (2.5kV RMS, 3.75kVRMS -H Option) Long Life / High Reliability RoHS / Pb-Free / REACH Compliant
© 2014 Solid State Optronics • San José, CA Page 2 of 9 AD4C213 /H/S/TR Rev 2.00 (03/05/2014) 001801 AD4C213
1 Form A / 1 Form B
400V / 25 Ω MOSFET Output Solid State Relay Parameter Symbol Min. Typ. Max. Units Test Conditions Input Specifications LED Forward Voltage V F - 1.2 1.5 V I F = 10mA LED Reverse Voltage BV R 5 - - V I R = 10μA Turn-On Current (Form A – Normally Open) I F(NO) - 1.5 5 mA I O = 150mA Turn-On Current (Form B – Normally Closed) I F(NC) - 0.5 - mA I O = 150mA Turn-Off Current (Form A – Normally Open) I FOFF(NO) - 0.5 - mA I O = 150mA Turn-Off Current (Form B – Normally Open) I FOFF(NC) - 1.5 5 mA I O = 150mA Output Specifications – Form A (Normally Open) Blocking Voltage V B 400 - - V IO=1A Continuous Load Current I O - - 150 mA I F=5mA On Resistance R ON - 17 25 Ω IF=5mA, IO=150mA Leakage Current I Oleak - 0.2 1 A IF=0mA, VO=400V Output Capacitance C OUT - 25 - pF V O=25V, f=1.0MHz Offset Voltage V OFFSET - - 0.2 mV I F=5mA Turn-On Time T ON - 1 5 mS IF=5mA, IO=150mA Turn-Off Time T OFF - 0.05 5 mS IF=0mA, IO=150mA Output Specifications – Form B (Normally Closed) Blocking Voltage V B 400 - - V IF=5mA, IO=1A Continuous Load Current I O - - 150 mA I F=0mA On Resistance R ON - 20 25 Ω IF=0mA, IO=150mA Leakage Current I Oleak - 0.2 1 A IF=5mA, VO=400V Output Capacitance C OUT - 15 - pF I F=5mA, VO=25V, f=1.0MHz Offset Voltage V OFFSET - - 0.2 mV I F=0mA Turn-On Time T ON - 0.1 5 mS IF=0mA, IO=150mA Turn-Off Time T OFF - 1 5 mS IF=5mA, IO=150mA Coupled Specifications Coupled Capacitance C COUPLED - 3 - pF Contact Transient Ratio - 2,000 7,000 0 V/S dV = 50V Isolation Specifications Isolation Voltage V ISO 2,500 - - V RMS RH ≤ 50%, t=1min -H Option V ISO 3,750 - - V RMS RH ≤ 50%, t=1min Input-Output Resistance R I-O - 10 - VI-O = 500VDC Electrical Characteristics, TA = 25°C (unless otherwise specified)
© 2014 Solid State Optronics • San José, CA Page 3 of 9 AD4C213 /H/S/TR Rev 2.00 (03/05/2014) 001801 AD4C213 400V / 25 Ω MOSFET Output Solid State Relay AD4C213 Performance & Characteristics Plots, TA = 25°C (unless otherwise specified)
© 2014 Solid State Optronics • San José, CA Page 4 of 9 AD4C213 /H/S/TR Rev 2.00 (03/05/2014) 001801 AD4C213 400V / 25 Ω MOSFET Output Solid State Relay AD4C213 Performance & Characteristics Plots, Cont… TA = 25°C (unless otherwise specified)
© 2014 Solid State Optronics • San José, CA Page 5 of 9 AD4C213 /H/S/TR Rev 2.00 (03/05/2014) 001801 AD4C213 400V / 25 Ω MOSFET Output Solid State Relay Process Step Description Parameter A Preheat Start Temperature (ºC) 150ºC B Preheat Finish Temperature (ºC) 180ºC C Preheat Time (s) 90 - 120s D Melting Temperature (ºC) 230ºC E Time above Melting Temperature (s) 30s F Peak Temperature, at Terminal (ºC) 260ºC G Dwell Time at Peak Temperature (s) 10s H Cool-down (ºC/s) <6ºC/s AD4C213 Solder Temperature Profile Recommendations (1) Infrared Reflow: Refer to the following figure as an example of an optimal temperature profile for single occurrence infrared reflow. Soldering process should not exceed temperature or time limits expressed herein. Su rface temperature of device package should not exceed 250ºC: A B C D F E G H (2) Wave Solder: (3) Hand Solder: Maximum Temperature: 260ºC (at terminal) Maximum Time: 10s Pre-heating: 100 - 150ºC (30 - 90s) Single Occurrence Maximum Temperature: 350ºC (at tip of soldering iron) Maximum Time: 3s Single Occurrence Figure 1
© 2014 Solid State Optronics • San José, CA Page 6 of 9 AD4C213 /H/S/TR Rev 2.00 (03/05/2014) 001801 AD4C213 400V / 25 Ω MOSFET Output Solid State Relay All dimensions in inches [“] with millimeters in parenthesis ()
© 2014 Solid State Optronics • San José, CA Page 7 of 9 AD4C213 /H/S/TR Rev 2.00 (03/05/2014) 001801 AD4C213 400V / 25 Ω MOSFET Output Solid State Relay 8 PIN SMD Surface Mount Package (-S) Note: All dimensions in inches [“] with millimeters in parenthesis ()
© 2014 Solid State Optronics • San José, CA Page 8 of 9 AD4C213 /H/S/TR Rev 2.00 (03/05/2014) 001801 AD4C213 400V / 25 Ω MOSFET Output Solid State Relay
8 PIN SMD Tape & Reel (-STR) Note: All dimensions in millimeters
© 2014 Solid State Optronics • San José, CA Page 9 of 9 AD4C213 /H/S/TR Rev 2.00 (03/05/2014) 001801 AD4C213 400V / 25 Ω MOSFET Output Solid State Relay Note: All weights above are in GRAMS, and include packaging materials where applicable Device Single Unit Full Tube (50pcs) Full Pouch (10 tubes) Full Reel (1000pcs) AD4C213-(H) 0.54 48 490 - AD4C213-(H)S 0.53 46 470 - AD4C213-(H)STR 0.53 - - 952 Solid State Optronics (SSO) makes no warranties or representations with regards to the completeness and accuracy of this document. SSO reserves the right to make changes to product description, specifications at any time without further notices. SSO shall not assume any liability arising out of the application or use of any product or circuit described herein. Neither circuit patent licenses nor indemnity are expressed or implied. Except as specified in SSO’s Standard Terms & Conditions, SSO disclaims liability for consequential or other damage, and we make no other warranty, expressed or implied, including merchantability and fitness for particular use. DISCLAIMER SSO does not authorize use of its devices in life support applications wherein failure or malfunction of a device may lead to personal injury or death. Users of SSO devices in life support applications assume all risks of such use and agree to indemnify SSO against any and all damages resulting from such use. Life support devices are defined as devices or systems which, (a) are intended for surgical implant into the body, or (b) support or sustain life, and (c) whose failure to perform when used properly in accordance with instructions for use can be reasonably expected to result in significant injury to the user, or (d) a critical component of a life support device or system whose failure can be reasonably expected to cause failure of the life support device or system, or to affect its safety or effectiveness. LIFE SUPPORT POLICY AD4C213 YYWW Date Code Pin 1