Features
■ Triac with overvoltage protection ■ Low IGT (<10 mA) or high immunity (IGT<35 mA) version ■ High noise immunity: static dV/dt > 1000 V/µs ■ TO-220FPAB insulated package: 1500 V rms Benefits ■ Enables equipment to meet IEC 61000-4-5 ■ High off-state reliability with planar technology ■ Needs no external overvoltage protection ■ Reduces the power passive component count ■ High immunity against fast transients described in IEC 61000-4-4 standards
Applications
■ AC mains static switching in appliance and industrial control systems ■ Drive of medium power AC loads such as: – Universal motor of washing machine drum – Compressor for fridge or air conditioner
Description
The ACST4 series belongs to the ACS™/ACST power switch family built with A.S.D.® (application specific discrete) technology. This high performance device is suited to home appliances or industrial systems, and drives loads up to 4 A. This ACST4 switch embeds a Triac structure and a high voltage clamping device able to absorb the inductive turn-off energy and withstand line transients such as those described in the IEC 61000-4-5 standards. The ACST410 needs only a low gate current to be activated (I GT < 10 mA) and still shows a high noise immunity complying with IEC standards such as IEC 61000-4-4 (fast transient burst test). Figure 1. Functional diagram TM: ACS is a trademark of STMicroelectronics. Table 1. Device summary
1 Characteristics
Table 2. Absolute ratings (limiting values)
- According to test described in IEC 61000-4-5 standard and Figure 19.
Table 3. Electrical characteristics
- Minimum I GT is guaranteed at 5% of IGT max
- For both polarities of OU T pin referenced to COM pin
2 Application information
2.1 Typical application description
resistor as shown Figure 16 and Figure 17. Figure 16. Compressor control – typical diagrams
Figure 17. Universal drum motor control – typical diagram
2.2 AC line transient voltage ruggedness
high turn-on current ramp up. recovers its blocking voltage capability after the surge and the next zero current crossing. Such a non repetitive test can be done at least 10 times on each AC line voltage polarity.
3 Ordering information scheme
Figure 20. Ordering information scheme
4 Package information
- Epoxy meets UL94, V0
- Cooling method: by conduction (C)
- Recommended torque value(TO220FPAB): 0.4 to 0.6 N·m In order to meet environmental requirements, ST offers these devices in different grades of ECOPACK® packages, depending on their level of environmental compliance. ECOPACK® specifications, grade definitions and product status are available at: www.st.com. ECOPACK® is an ST trademark.
Table 6. TO-220FPAB dimensions
Figure 21. Footprint (dimensions in mm) Table 7. DPAK dimensions
5 Ordering information
Table 8. Ordering information
6 Revision history
Table 9. Document revision history Jan-2003 3A Previous update. 04-Jul-2007 4 Reformatted to current standard. Added package. 18-Dec-2009 5 V DRM/VRRM updated to 800 V. Order codes updated.