ACSL-6XX0 HP | Alldatasheet
Document overview
- Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
- PDF pages: 10
Technical content
Features
- Available in dual, triple and quad channel configurations
- Bi-directional
- Wide supply voltage range 3.0V to 5.5V
- High-speed: 15 MBd typical,
10 MBd minimum
- 10 kV/ µs minimum Common Mode Rejection (CMR) at Vcm = 1000 V
- LSTTL/TTL compatible
- Safety and regulatory approvals (Pending) – 2500Vrms for 1 min per UL1577 – CSA Component Acceptance – IEC/EN/DIN EN 60747-5-2
- 16 Pin narrow-body SOIC package for triple and quad channel
- -40 to 100 °C temperature range CAUTION: It is advised that normal static precautions be taken in handling and assembly of this component to prevent damage and/or degradation, which may be induced by ESD.
Applications
- Full duplex communication
- Isolated line receiver
- Computer-peripheral interfaces
- Microprocessor system interfaces
- Digital isolation for A/D and D/A conversion
- Switching power supply
- Instrument input/output isolation
- Ground loop elimination
- Pulse transformer replacement
Device Number Channel Configuration Package ACSL-6210 Dual, Bi-Directional\` 8-pin Small Outline ACSL-6300* Triple, All-in-One 16-pin Small Outline ACSL-6310* Triple, Bi-Directional, 2/1 16-pin Small Outline ACSL-6400 Quad, All-in-One 16-pin Small Outline ACSL-6410* Quad, Bi-Directional, 3/1 16-pin Small Outline ACSL-6420* Quad, Bi-Directional, 2/2 16-pin Small Outline * Advanced Information Pin Description Symbol Description Symbol Description VDD1 Power Supply 1 GND 1 Power Supply Ground 1 VDD2 Power Supply 2 GND 2 Power Supply Ground 2 ANODEx LED Anode NC Not Connected CATHODEx LED Cathode V OX Output Signal Truth Table (Positive Logic) LED OUTPUT ON L OFF H
Ordering Information
A C S L - 6 X X 0 - X Y Z E Channel Configuration (Refer to the Device Selection Guide) Lead Free Option R = SO-8 Package, 100 units per tube T = SO-16 Package, 50 units per tube 6 = IEC/EN/DIN EN 60747-5-2, VIORM = 560V peak Option 5 = Tape and Reel Packaging Option, 1500 units per reel for SO-8 Package and 1000 units per reel for SO-16 Package
ACSL-6210 - Dual-Ch, Bi-Dir ACSL-6300 - Triple-Ch, All-in-One* ACSL-6310 - Triple-Ch, Bi-Dir (2/1)* ACSL-6400 - Quad-Ch, All-in-One ACSL-6410 - Quad-Ch, Bi-Dir (3/1)* ACSL-6420 - Quad-Ch, Bi-Dir (2/2)* * Advanced Information
0.228 (5.791) 0.244 (6.197) 0.386 (9.802) 0.394 (9.999) 0.152 (3.861) 0.157 (3.988) 0.013 (0.330) 0.020 (0.508) 0.040 (1.016) 0.060 (1.524) 0.050 (1.270) 0.060 (1.524) 0.054 (1.372) 0.068 (1.727) 0.004 (0.102) 0.010 (0.249) 0.016 (0.406) 0.050 (1.270) 0.010 (0.245) 0.010 (0.249) x 45°ß 0° – 8° TYP DIMENSIONS: INCHES (MILLIMETERS) MIN MAX 87 65 4321 0.228 (5.80) 0.244 (6.20) 0.189 (4.80) 0.197 (5.00) 0.150 (3.80) 0.157 (4.00) 0.013 (0.33) 0.020 (0.51) 0.040 (1.016) 0.060 (1.524) 0.004 (0.10) 0.069 (1.75) 0.016 (0.40) 0.050 (1.27) 0.008 (0.19) 0.010 (0.25) 0.010 (0.25) 0.020 (0.50) x 45° DIMENSIONS: INCHES (MILLIMETERS) MIN MAX ACSL-6210 Small Outline SO-8 Package ACSL-6300*, ACSL-6310*, ACSL-6400, ACSL-6410* and ACSL-6420* Small Outline SO-16 Package Package Outline Drawings
TIME (SECONDS) TEMPERATURE (°C) 200 100 50 150 100 200 250 300 SEC. 50 SEC. SEC. 160°C 140°C 150°C PEAK TEMP. 245°C PEAK TEMP. 240°C PEAK TEMP. 230°C SOLDERING TIME 200°C PREHEATING TIME 150°C, 90 ± 30 SEC. 2.5°C ± 0.5°C/SEC. 3°C + 1°C/–0.5°C TIGHT TYPICAL LOOSE ROOM TEMPERATURE PREHEATING RATE 3°C + 1°C/–0.5°C/SEC. REFLOW HEATING RATE 2.5°C ± 0.5°C/SEC. Solder Reflow Temperature Profile Pb-free IR Profile
Insulation and Safety Related Specifications Parameter Symbol Value Units Conditions Minimum External Air Gap (Clearance) L(I01) 4.9 mm Measured from input terminals to output terminals, shortest distance through air Minimum Externa l Tracking(Creepage) L(I02) 4.5 mm Measured from input terminals to output terminals, shortest distance path through body Minimum Internal Plastic Gap (Internal Clearance) 0.08 mm Insulation thickness between emitter and detector; also known as distance through insulation Tracking Resistance (Comparative T racking Index) CTI 175 Volts DIN IEC 112/VDE0303 Part 1 Isolation Group IIIa Material Group (DIN VDE 0110, 1/89, Table 1) IEC/EN/DIN EN 60747-5-2 Insulation Related Characteristics (Option X6X Only) Description Symbol ACSL-6XX0-X6X Units Installation Classification per DIN VDE 0110/1.89, Table 1 for rated mains voltage ≤150V rms I-IV for rated mains voltage ≤300V rms I-III Climatic Classification 55/100/21 Pollution Degree (DIN VDE 0110/1.89) 2 Maximum Working Insulation Voltage V IORM 560 V peak Input to Output T est Voltage, Method b * V PR 1050 V peak VIORM x 1.875 = VPR, 100% Production T est with tm = 1 sec, Partial Discharge < 5 pC Input to Output T est Voltage, Method a * V PR 840 V peak VIORM x 1.5 = VPR, T ype and Sample T est, Tm = 60 sec, Partial Discharge < 5 pC Highest Allowable Overvoltage * V IOTM 4000 V peak (Transient Overvoltage, tini = 10 sec) Safety Limiting Values (Maximum values allowed in the event of a failure) Case T emperature T S 175 °C Input Current I S,INPUT 150 mA Output Power P S,OUTPUT 600 mW Insulation Resistance at TS, VIO = 500V R IO 109 Ω *Refer to the front of the optocoupler section of the current catalog, under Product Safety Regulations section, IEC/EN/DIN EN 60747-5-2, for a detailed description. Note: Isolation characteristics are guaranteed only within the safety maximum ratings, which must be ensured by protective circuits in application.
Parameter Symbol Min. Max. Units Storage T emperature T s -55 125 °C Operating T emperature T A -40 100 °C Supply Voltage (1 Minute Maximum) V DD1 , VDD2 7V Reverse Input Voltage (Per Channel) V R 5V Output Voltage (Per Channel) V O 7V Average Forward Input Current[1] (Per Channel) I F 15 mA Output Current (Per Channel) I O 50 mA Input Power Dissipation[2] (Per Channel) P 1 27 mW Output Power Dissipation[2] (Per Channel) P O 60 mW Recommended Operating Conditions Parameter Symbol Min. Max. Units Operating T emperature T A -40 100 °C Input Current, Low Level[3] IFL 0 250 µA Input Current, High Level[4] IFH 71 5 m A Supply Voltage V DD1, VDD2 3.0 5.5 V Fan Out (at TA= 1kΩ) N 5 TTL Loads Output Pull-up Resistor R L 330 4k Ω Notes: 1. Peaking circuits may produce transient input currents up to 50 mA, 50 ns max. pulse width, provided average current does not exceed its max. values. 2. Derate total package power dissipation, P T linearly above +80°C free-air temperature at a rate of 5.45 mW/°C for the SO8 package. PT=number of channels multiply by (PI+PO). For SO16 package data, contact factory for assistance. 3. The off condition can be guaranteed by ensuring that VFL ≤ 0.8V. 4. The initial switching threshold is 7 mA or less. It is recommended that minimum 8 mA be used for best performance and to permit guardband for LED degradation.
Over recommended operating range (3.0V ≤ VDD1 ≤ 3.6V, 3.0V ≤ VDD2 ≤ 3.6V, TA = -40°C to +100°C) unless otherwise specified. All typical specifications are at TA = +25°C , VDD1 = VDD2 = +3.3V. Parameter Symbol Min. Typ. Max. Units Test Conditions Input Threshold Current I TH 2.7 7.0 mA I OL(Sinking)=13 mA, VO = 0.6V High Level Output Current I OH 4.7 100.0 µAI F = 250 µA, VO = 3.3V Low Level Output Voltage V OL 0.36 0.68 V I OL(Sinking) = 13 mA, IF = 7mA High Level Supply Current (per channel) I DDH 3.2 5.0 mA I F =0 m A Low Level Supply Current (per channel) I DDL 4.6 7.5 mA I F = 10 mA Input Forward Voltage V F 1.25 1.52 1.80 V I F = 10 mA, TA =2 5°C Input Reverse Breakdown Voltage BV R 5.0 V I R =1 0 µA Input Diode T emperature Coefficient ∆VF / ∆TA -1.8 mV/ °CI F =1 0 m A Input Capacitance C IN 80 pF f = 1 MHz, V F = 0 V Switching Specifications unless otherwise specified. All typical specifications are at TA = +25°C , VDD1 = VDD2 = +3.3V. Parameter Symbol Min. Typ. Max. Units Test Conditions Maximum Data Rate 10 15 MBd R L = 350Ω, CL = 15 pF Pulse Width t PW 100 ns R L = 350Ω, CL = 15 pF Propagation Delay Time to Logic High Output Level[5] tPLH 52 100 ns R L = 350Ω, CL = 15 pF Propagation Delay Time to Logic Low Output Level[6] tPHL 44 100 ns R L = 350Ω, CL = 15 pF Pulse Width Distortion |tPHL – tPLH| |PWD| 8 35 ns R L = 350Ω, CL = 15 pF Propagation Delay Skew[7] tPSK 40 ns R L = 350Ω, CL = 15 pF Output Rise Time (10 – 90%) t R 35 ns R L = 350Ω, CL = 15 pF Output Fall Time (10 – 90%) t F 12 ns R L = 350Ω, CL = 15 pF Logic High Common Mode Transient Immunity [8] |CMH| 10 kV/ µsV cm = 1000V, IF = 0 mA, VO = 2.0V, RL = 350Ω, TA = 25°C Logic Low Common Mode Transient Immunity [8] |CML| 10 kV/ µsV cm = 1000V, IF = 8 mA, VO = 0.8V, RL = 350Ω, TA = 25°C Notes: 5. t PLH is measured from the 4.0 mA level on the falling edge of the input pulse to the 1.5V level on the rising edge of the output pulse. 6. t PHL is measured from the 4.0 mA level on the rising edge of the input pulse to the 1.5V level on the falling edge of the output pulse. 7. t PSK is equal to the worst case difference in tPHL and/or tPLH that will be seen between units at any given temperature and specified test conditions. 8. CM H is the maximum common mode voltage slew rate that can be sustained while maintaining VO > 2.0V. CML is the maximum common mode voltage slew rate that can be sustained while maintaining VO < 0.8V. The common mode voltage slew rates apply to both rising and falling common mode voltage edges.
Over recommended operating range (4.5V ≤ VDD1 ≤ 5.5V, 4.5V ≤ VDD2 ≤ 5.5V, TA = -40°C to +100°C) unless otherwise specified. All typical specifications are at TA = +25°C, VDD1 = VDD2 = +5.0V. Parameter Symbol Min. Typ. Max. Units Test Conditions Input Threshold Current I TH 2.7 7.0 mA I OL(Sinking)=13 mA, VO= 0.6V High Level Output Current I OH 3.8 100.0 µAI F = 250 µA, VO= 5.5V Low Level Output Voltage V OL 0.36 0.6 V I OL(Sinking)=13 mA, IF=7 mA High Level Supply Current (per channel) I DDH 4.3 7.5 mA I F = 0 mA Low Level Supply Current (per channel) I DDL 5.8 10.5 mA I F = 10 mA Input Forward Voltage V F 1.25 1.52 1.8 V I F = 10 mA, TA = 25°C Input Reverse Breakdown Voltage BV R 5.0 V I R = 10 µA Input Diode T emperature Coefficient ∆VF / ∆TA -1.8 mV/ °CI F = 10 mA Input Capacitance C IN 80 pF f = 1 MHz, V F = 0 V Switching Specifications unless otherwise specified. All typical specifications are at TA=+25°C, VDD1 = VDD2 = +5.0V. Parameter Symbol Min. Typ. Max. Units Test Conditions Maximum Data Rate 10 15 MBd R L = 350Ω, CL =15 pF Pulse Width t PW 100 ns R L = 350Ω, CL =15 pF Propagation Delay Time to Logic High Output Level[5] tPLH 46 100 ns R L = 350Ω, CL =15 pF Propagation Delay Time to Logic Low Output Level[6] tPHL 43 100 ns R L = 350Ω, CL =15 pF Pulse Width Distortion |tPHL – tPLH| |PWD| 5 35 ns R L = 350Ω, CL =15 pF Propagation Delay Skew[7] tPSK 40 ns R L = 350Ω, CL =15 pF Output Rise Time (10 – 90%) t R 30 ns R L = 350Ω, CL =15 pF Output Fall Time (10 – 90%) t F 12 ns R L = 350Ω, CL =15 pF Logic High Common Mode Transient Immunity [8] |CMH| 10 kV/ µsV cm= 1000V, IF=0 mA, VO = 2.0V, RL=350Ω, TA = 25°C Logic Low Common Mode Transient Immunity [8] |CML| 10 kV/ µsV cm= 1000V, IF= 8 mA, VO = 0.8V, RL= 350Ω, TA = 25°C Notes: 5. t PLH is measured from the 4.0 mA level on the falling edge of the input pulse to the 1.5V level on the rising edge of the output pulse. 6. t PHL is measured from the 4.0 mA level on the rising edge of the input pulse to the 1.5V level on the falling edge of the output pulse. 7. t PSK is equal to the worst case difference in tPHL and/or tPLH that will be seen between units at any given temperature and specified test conditions. 8. CM H is the maximum common mode voltage slew rate that can be sustained while maintaining VO > 2.0V. CML is the maximum common mode voltage slew rate that can be sustained while maintaining V O < 0.8V. The common mode voltage slew rates apply to both rising and falling common mode voltage edges.
All specifications are at TA=+25°C. Parameter Symbol Min. Typ. Max. Units Test Conditions Input-Output Momentary SO8 V ISO 2500 V RMS RH ≤50%, t = 1 min Withstand Voltage[9] SO16 V ISO 2500 RH ≤50%, t = 1 min Input-Output Insulation[10] [11] SO8 I I-O 5 µA 45% RH, t=5 sec, V I-O= 3kV DC SO16 I I-O 5 45% RH, t=5 sec, V I-O=3kV DC Input-Output Resistance[10] SO8 R I-O 109 1011 Ω VI-O= 500V DC SO16 R I-O 109 1011 VI-O= 500V DC Input-Output Capacitance[10] SO8 C I-O 0.7 pF f = 1 MHz SO16 C I-O 0.7 f = 1 MHz Input-Input Insulation SO8 I I-I 0.005 µAR H ≤45%, t = 5 sec, VI-I = 500V Leakage Current[12] SO16 I I-I 0.005 RH ≤45%, t = 5 sec, VI-I = 500V Input-Input Resistance[12] SO8 R I-I 1011 Ω RH ≤45%, t= 5 sec, VI-I = 500V SO16 R I-I 1011 RH ≤45%, t =5 sec, VI-I =500V Input-Input Capacitance[12] SO8 C I-I 0.1 pF f = 1 MHz SO16 C I-I 0.12 f = 1 MHz Electrostatic Discharge Sensitivity This product has been tested for electrostatic sensitivity to the limits stated in the specifications. However, Agilent recommends that all integrated circuits be handled with appropriate care to avoid damage. Damage caused by inappropriate handling or storage could range from performance degradation to complete failure. www.agilent.com/semiconductors For product information and a complete list of distributors, please go to our web site. For technical assistance call: Americas/Canada: +1 (800) 235-0312 or (916) 788-6763 Europe: +49 (0) 6441 92460 China: 10800 650 0017 Hong Kong: (65) 6756 2394 India, Australia, New Zealand: (65) 6755 1939 Japan: (+81 3) 3335-8152(Domestic/International), or 0120-61-1280(Domestic Only) Korea: (65) 6755 1989 Singapore, Malaysia, Vietnam, Thailand, Philippines, Indonesia: (65) 6755 2044 Taiwan: (65) 6755 1843 Data subject to change. Copyright © 2004 Agilent Technologies, Inc. November 1, 2004 5989-1343EN Notes: 9. V ISO is a dielectric voltage rating that should not be interpreted as an input-output continuous voltage rating. For continuous voltage rating, refer to the IEC/EN/DIN EN 60747-5-2 Insulation Characteristics T able (if applicable), the equipment level safety specification or Agilent Application Note 1074 entitled “Optocoupler Input-Output Endurance Voltage.” 10. Measured between each input pair shorted together and all output connections for that channel shorted together. 11. In accordance to UL1577, each optocoupler is proof tested by applying an insulation test voltage ≥ 3000 Vrms for 1 sec (leakage detection current limit, I I-O ≤ 5 µA). This test is performed before the 100% production test for partial discharge (Method b) shown in the IEC/EN/DIN EN 60747-5-2 Insulation Characteristics Table, if applicable. 12. Measured between inputs with the LED anode and cathode shorted together.