ACS302 STMICROELECTRONICS | Alldatasheet

Document overview

  • Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
  • PDF pages: 12

Technical content

1 Characteristics

Table 2. Absolute maximum ratings – for one switch and TJ = 25 °C, unless otherwise specified

  1. According to test described by IEC 61000-4-5 standard and figure 3

Table 3. Electrical characteristics (for one switch and Tj = 25°C, unless otherwise specified)

2 AC line switch basic application

door locks and low power lamps. diagram. No protection devices are required between the gates and common terminals. In appliance systems, this ACS drives slow power loads in full cycle ON / OFF mode. without any additional turn-off snubber. Figure 16. Typical application

2.1 High Inductive switch-off operation

time, the voltage across the switch is limited to the clamping voltage VCL. is dissipated in the clamping diode section that is especially designed for that purpose.

2.2 AC line transien t voltage ruggedness

low energy spikes or by breaking over under high energy shocks. Figure 20. Such non repetitive test can be done 10 times on each AC line voltage polarity. Figure 17. Turn-off operation of the ACS302 Figure 18. ACS302 switch static characteristic

3 Package information

specifications, grade definitions and product status are available at: www.st.com. ECOPACK® is an ST trademark. Figure 21. SO-20 dimension definitions Table 6. SO-20 dimensions

Figure 22. Footprint (dimensions in mm)

4 Ordering Information

Figure 23. Ordering information scheme Table 7. Ordering information

5 Revision history

Table 8. Document revision history 01-Jul-2013 1 First release.