Datasheet - ACS108-8SA - 0.8 A - 800 V overvoltage protected AC switch (ACS™)
Document overview
- Manufacturer or author: STMICROELECTRONICS
- PDF pages: 13
Technical content
Features
- Enables equipment to meet IEC 61000-4-5 surge with overvoltage crowbar technology
- High noise immunity against static dV/dt and IEC 61000-4-4 burst
- Needs no external protection snubber or varistor
- Reduces component count by up to 80% and Interfaces directly with the micro- controller
- Common package tab connection supports connection of several alternating current switches on the same cooling pad
- V CL gives headroom before clamping then crowbar action
Applications
- Alternating current on/off static switching in appliances and industrial control systems
- Driving low power high inductive or resistive loads like: – relay, valve, solenoid, dispenser – pump, fan, low power motor, door lock, air flow dumper – lamp
Description
The ACS108-8SA belongs to the AC switch range (built with A. S. D.® technology). This high performance switch can control a load of up to 0.8 A. This device switch includes an overvoltage crowbar structure to absorb the inductive turn-off energy, and a gate level shifter driver to separate the digital controller from the main switch. It is triggered with a negative gate current flowing out of the gate pin. Note: ®: A.S.D. is a registered trademark of STMicroelectronics Note: TM: ACS is a trademark of STMicroelectronics Product status link ACS108-8SA Product summary IT(RMS) 0.8 A VDRM, VRRM 800 V IGT 10 mA
0.8 A - 800 V overvoltage protected AC switch (ACS™)
DS12901 - Rev 1 - February 2019 For further information contact your local STMicroelectronics sales office.
1 Characteristics
Table 1. Absolute maximum ratings (Tamb = 25 °C, unless otherwise specified)
- according to test described by standard IEC 61000-4-5, see Figure 15. Overvoltage ruggedness test circuit for resistive and
Table 2. Electrical characteristics (Tj = 25 °C, unless otherwise specified)
- Minimum I GT is guaranteed at 10% of IGT max.
Table 3. Static electrical characteristics
- For both polarities of OUT pin referenced to COM pin
Table 4. Thermal characteristics
1.1 Characteristics (curves)
Figure 1. Maximum power dissipation versus rms on-state Figure 2. On-state rms current versus ambient Figure 3. Relative variation of thermal impedance junction Figure 4. Relative variation of holding and latching
2 Alternating current mains switch - basic application
power high inductive load with neither varistor nor additional turn-off snubber. Figure 13. Typical application schematic
2.1 Protection against overvoltage: the best choice is ACS
In comparison with standard Triacs the ACS108 is over-voltage self-protected, as specified by the parameter VCL. voltage that can occur on the electrical network.
2.1.1 High inductive load switch-off: turn-off overvoltage clamping
occur when the gate current is removed and the OUT current is lower than IH.
Figure 14. Switching off of a high inductive load - typical clamping capability of ACS108 (Tamb = 25 °C)
2.1.2 Alternating current mains transient voltage ruggedness
or by breaking-over when subjected to high energy shocks, even with high turn-on current rises. Figure 16. Typical current and voltage waveforms across the ACS108 (+2 kV surge, IEC 61000-4-5 standard). Such non-repetitive tests can be done 10 times on each AC mains voltage polarity.
3 Package information
In order to meet environmental requirements, ST offers these devices in different grades of ECOPACK® packages, depending on their level of environmental compliance. ECOPACK® specifications, grade definitions and product status are available at: www.st.com. ECOPACK® is an ST trademark.
3.1 TO-92 package information
- Epoxy meets UL94, V0
- Lead free plating + halogen-free molding resin
Figure 17. TO-92 package outline Table 5. TO-92 package mechanical data
- Inches dimensions given for information
Package information
DS12901 - Rev 1 page 10/13
4 Ordering information
Figure 18. Ordering information scheme Table 6. Ordering information
2500 Bulk
- First row = ACS108, second row = 8SA
Ordering information
DS12901 - Rev 1 page 11/13
Revision history
Table 7. Document revision history 25-Feb-2019 1 Initial release.